Quốc gia: Tây Ban Nha
Ngôn ngữ: Tiếng Tây Ban Nha
Nguồn: DrWeigert
Dr. Weigert
Fecha de revisión: 02.02.2016 Fecha de impresión 29.06.17 2 / ES- 800882-001-02 Versión: 2 / ES Sustituye a la versión: 1 / ES HOJA DE DATOS DE SEGURIDAD SEGÚN (CE) NR. 1907/2006 NEODISHER SEPTO 3000 Página 1(12) SECCIÓN 1. IDENTIFICACIÓN DE LA SUSTANCIA O LA MEZCLA Y DE LA SOCIEDAD O LA EMPRESA 1.1. IDENTIFICADOR DEL PRODUCTO neodisher Septo 3000 1.2. USOS PERTINENTES IDENTIFICADOS DE LA SUSTANCIA O DE LA MEZCLA Y USOS DESACONSEJADOS USO DE LA SUSTANCIA O DEL PREPARADO desinfectantes 1.3. DATOS DEL PROVEEDOR DE LA FICHA DE DATOS DE SEGURIDAD DIRECCIÓN: Chemische Fabrik Dr. Weigert GmbH & Co. KG Mühlenhagen 85 D-20539 Hamburg Teléfono +49 40 789 60 0 Fax +49 40 789 60 120 www.drweigert.com DIRECCIÓN DE E-MAIL DE LA PERSONA RESPONSABLE DE ESTA FDS: sida@drweigert.de 1.4. TELÉFONO DE EMERGENCIA GBK/ Infotrac: (USA domestic) 1 800 535 5053 or international +1 352 323 3500 En caso de accidente consultar al Servicio Médico de Información Toxicológica. Tlf: 91 562 04 20 SECCIÓN 2. IDENTIFICACIÓN DE LOS PELIGROS 2.1. CLASIFICACIÓN DE LA SUSTANCIA O DE LA MEZCLA CLASIFICACIÓN (REGLAMENTO (CE) Nº 1272/2008) Clasificación (Reglamento (CE) nº 1272/2008) Acute Tox. 4 H302 Acute Tox. 4 H332 Skin Corr. 1A H314 Eye Dam. 1 H318 Skin Sens. 1 H317 Resp. Sens. 1 H334 STOT SE 3 H335 Muta. 2 H341 Carc. 1B H350 2.2. ELEMENTOS DE LA ETIQUETA MARCACIÓN CONFORME AL REGLAMENTO (CE), Nº 1272/2008 PICTOGRAMAS DE PELIGRO PALABRA DE ADVERTENCIA Peligro Fecha de revisión: 02.02.2016 Fecha de impresión 29.06.17 2 / ES- 800882-001-02 Versión: 2 / ES Sustituye a la versión: 1 / ES HOJA DE DATOS DE SEGURIDAD SEGÚN (CE) NR. 1907/2006 NEODISHER SEPTO 3000 Página 2(12) INDICACIONES DE PELIGRO H302+H332 Nocivo en caso de ingestión o inhalación. H314 Provoca quemaduras graves en la piel y lesiones oculares graves. H317 Puede provocar una reacción alérgica en la piel. H334 Puede provocar síntomas de alergia o asma o dificultades respiratorias en caso de inhalación. H335 Puede irritar las vías respiratorias. H341 Se Đọc toàn bộ tài liệu
WWW.DRWEIGERT.COM neodisher ® Septo 3000 With the above information, to our current knowledge we describe our product regarding safety necessities, but we do not involve any quality description or promise certain properties. Chemische Fabrik Dr. Weigert GmbH & Co. KG Tel.: +49-40-7 89 60-0 info@drweigert. de Mühlenhagen 85 • D-20539 Hamburg Fax: +49-40-7 89 60-120 www. drweigert. de Disinfectant for the manual reprocessing of thermostable and thermolabile instruments Liquid concentrate Fields of application: • Disinfection of thermostable and thermolabile medical devices in immersion or ultrasonic baths • Also suitable for the disinfection of flexible endoscopes Performance spectrum: • Bactericidal, fungicidal, mycobactericidal, virucidal and sporicidal activity. Confirmed by certification • Suitable for all standard materials such as stainless steel, chrome-nickel steel, plastics, rubber, porcelain and glass • For manual pre-cleaning the use of neodisher MediClean forte is recommended Special properties: • Wide range of activity, even with short action times • Excellent material compatibility • VAH 1 -listed , on the list of the IHO 2 for disinfectants with virucidal activity Application and dosage: neodisher Septo 3000 is used in immersion and ultrasonic baths. Depending on the desired activity the working solution must be prepared according to the below mentioned dosing recommendations. The working solution must always be prepared with cold water (at room temperature). Clean the instruments resp. endoscopes thoroughly, e.g. with the detergent neodisher MediClean forte prior to disinfection. Then place the instruments resp. endoscopes into the neodisher Septo 3000 working solution and adhere to the below mentioned contact times. Never exceed the limit for the exposure time in ultrasonic baths which is recommended by the instrument manufacturer. For correct disinfection in ultrasonic baths the contact times must be observed. Open and dismantle the instruments as far as possible. Ensure that a Đọc toàn bộ tài liệu