CILEST 250/35 microgram Oral Contraceptive Tablets Malta - English - Medicines Authority

cilest 250/35 microgram oral contraceptive tablets

janssen-cilag international nv turnhoutsewes 30, b-2340 beerse, belgium - norgestimate, ethinylestradiol - tablet - norgestimate 250 µg ethinylestradiol 35 µg - sex hormones and modulators of the genital system

Gore Excluder AAA Contralateral Leg Endoprosthesis - Abdominal aortic aneurysm stent Australia - English - Department of Health (Therapeutic Goods Administration)

gore excluder aaa contralateral leg endoprosthesis - abdominal aortic aneurysm stent

w l gore & associates (australia) pty ltd - 46777 - abdominal aortic aneurysm stent - the contralateral leg endoprosthesis consists of eptfe and fep, supported by nitinol wire along its external surface. an eptfe sleeve is used to constrain the endoprostheses on the leading edge of the delivery catheter. deployment is initiated from the leading (aortic) end and proceeds toward the trailing (iliac) end of the delivery catheter, which is supplied with the endoprosthesis. the gore? excluder? aaa endoprosthesis is intended to exclude the aneurysm from the blood circulation in patients diagnosed with infrarenal abdominal aortic aneurysm (aaa) disease and who have appropriate anatomy as described below: ? adequate iliac/femoral access ? infrarenal aortic neck treatment diameter range of 19 ? 32mm and a minimum aortic neck length of 15mm ? proximal aortic neck angulation ? 60? ? iliac artery treatment diameter range of 8 - 25mm and iliac distal vessel seal zone length of at least 10mm the aortic and iliac extender endoprostheses are intended to be used after deployment of the gore? excluder? aaa en

E-tegra Stent Graft System ? Contralateral Leg - Abdominal aortic aneurysm stent Australia - English - Department of Health (Therapeutic Goods Administration)

e-tegra stent graft system ? contralateral leg - abdominal aortic aneurysm stent

cryolife medical (australia) company pty ltd - 46777 - abdominal aortic aneurysm stent - the e-tegra stent graft system consists of two main components: the e-tegra stent graft and the e-tegra delivery system, in which the e-tegra stent graft is loaded. the implants of the e-tegra stent graft system are self-expanding, endoluminal stent grafts remaining in the body after deployment. the contralateral leg (cl) consists of an iliac segment and has a cylindrical or conical shape. the e-tegra stent graft system is indicated for the endovascular treatment of infrarenal aortic aneurysms. these aneurysms can also affect the common iliac artery.

Filshie Clip System - Contraceptive, tubal occlusion clip/band Australia - English - Department of Health (Therapeutic Goods Administration)

filshie clip system - contraceptive, tubal occlusion clip/band

femcare australia pty ltd - 33598 - contraceptive, tubal occlusion clip/band - disposable 7mm filshie clip applicator supplied sterile in a blister pack for single use with a pair of filshie clips supplied sterile in a blister pack. the filshie clip is manufactured from titanium and is lined on the inner surface with silicone rubber. the sterishot applicator consists of a plastic handle and metal shaft. the sterishot applicator can only apply one filshie clip at a time and can be reloaded to enable more filshie clips to be applied in the same patient. indicated for permanent female sterilization by occlusion of the fallopian tubes.

MULTILOAD CU EACH India - English - Central Drugs Standard Control Organization

multiload cu each

infar - contraceptive device - intrauterine copper contraceptive device prviding copper surface area of 250sq. mm - each

MULTILOAD CU EACH India - English - Central Drugs Standard Control Organization

multiload cu each

infar - contraceptive device - intrauterine copper contraceptive device prviding copper surface area of 375sq. mm - each