W L Gore & Associates (Australia) Pty Ltd - GORE Molding and Occlusion Balloon Catheter - Intravascular occluding/stent-graft post-dilation balloon catheter 澳大利亚 - 英文 - Department of Health (Therapeutic Goods Administration)

w l gore & associates (australia) pty ltd - gore molding and occlusion balloon catheter - intravascular occluding/stent-graft post-dilation balloon catheter

w l gore & associates (australia) pty ltd - 66383 - intravascular occluding/stent-graft post-dilation balloon catheter - a compliant polyurethane balloon is mounted on the leading end of a 3 lumen catheter shaft. termination of the leading end is an atraumatic catheter leading tip for smooth transition from the guidewire to catheter. radiopaque markers indicate the proximal and distal end of the balloon which aid in placement under fluoroscopy. both of the lumens facilitate balloon catheter preparation, inflation and deflation. at the trailing end is a dual port y-arm which allows for over-the-wire access. the gore? molding and occlusion balloon catheter (mob) is intended to serve as a balloon catheter accessory device. ballooning of a stent graft may improve molding of the graft material and fixation of the stent graft to the vessel wall. balloon occlusion of a large diameter vessel may provide hemostasis until vessel repair may be achieved.

Cook Zenith Alpha Abdominal Endovascular Graft 新加坡 - 英文 - HSA (Health Sciences Authority)

cook zenith alpha abdominal endovascular graft

cook south east asia pte ltd - cardiovascular - the zenith alpha abdominal endovascular graft and low profile aaa endovascular graft ancillary components are indicated for the treatment of patients with abdominal aortic or aorto-iliac aneurysms having morphology suitable for endovascular repair, including: • iliofemoral access vessel size and morphology (minimal thrombus, calcification and/or tortuosity) should be compatible with a 16 french (6.0 mm od) or 17 french (6.5 mm od) vascular introducer sheath; • non-aneurysmal infrarenal aortic segment (neck) proximal to the aneurysm: • with a length of at least 15 mm, • with a diameter measured outer wall to outer wall of no greater than 32 mm and no less than 18 mm, • with an angle less than 60 degrees relative to the long axis of the aneurysm, and • with an angle less than 45 degrees relative to the axis of the suprarenal aorta. • iliac artery distal fixation site greater than 10 mm in length and 8 to 20 mm in diameter (measured outer wall to outer wall).

Cook Zenith Low Profile AAA Endovascular Graft System 新加坡 - 英文 - HSA (Health Sciences Authority)

cook zenith low profile aaa endovascular graft system

cook south east asia pte ltd - cardiovascular - the zenith low profile aaa endovascular graft and ancillary components are indicated for the endovascular treatment of patients with abdominal aortic or aorto-iliac aneurysms having morphology suitable for endovascular repair, including: • iliac/femoral anatomy that is suitable for access with a 16 french (6.0mm od) introduction system; • non-aneurysmal infrarenal aortic segment (neck) proximal to the aneurysm: o with a length of at least 15mm o with a diameter measured outer wall to outer wall of no greater than 28mm and no less than 18mm o with an angle less than 60 degrees relative to the long axis of the aneurysm, and o with an angle less than 45 degrees relative to the axis of the suprarenal aorta • iliac artery distal fixation site greater than 10mm in length and 8 to 20mm in diameter (measured outer wall to outer wall).