Surgical procedure kit, neurosurgical, single-use, non-medicated 澳大利亚 - 英文 - Department of Health (Therapeutic Goods Administration)

surgical procedure kit, neurosurgical, single-use, non-medicated

integra neurosciences pty ltd - 44063 - surgical procedure kit, neurosurgical, single-use, non-medicated - the codman cranial access kit is indicated when a craniotomy is required for placement of (separately supplied) devices being used for intracranial pressure monitoring and/or cerebrospinal fluid drainage procedures.

Surgical procedure kit, neurosurgical, single-use, non-medicated 澳大利亚 - 英文 - Department of Health (Therapeutic Goods Administration)

surgical procedure kit, neurosurgical, single-use, non-medicated

medtronic australasia pty ltd - 44063 - surgical procedure kit, neurosurgical, single-use, non-medicated - the extension test cable is an external device intended to conduct electrical stimulation from the external neurostimulator to the extension dbs lead.

Surgical procedure kit, neurosurgical, single-use, non-medicated 澳大利亚 - 英文 - Department of Health (Therapeutic Goods Administration)

surgical procedure kit, neurosurgical, single-use, non-medicated

medtronic australasia pty ltd - 44063 - surgical procedure kit, neurosurgical, single-use, non-medicated - the lead test cable is an external device intended to conduct electrical stimulation from the external neurostimulator to the implanted dbs lead.

SenSight? Depth Stop and Cranial Tunneller Kit -Model B31010 - Surgical procedure kit, neurosurgical, single-use, non-medicated 澳大利亚 - 英文 - Department of Health (Therapeutic Goods Administration)

sensight? depth stop and cranial tunneller kit -model b31010 - surgical procedure kit, neurosurgical, single-use, non-medicated

medtronic australasia pty ltd - 44063 - surgical procedure kit, neurosurgical, single-use, non-medicated - the sensight depth stop and cranial tunneler kit includes components which can be used during delivery and implantation of the sensight directional lead. the depth stop is an external device intended to retain the lead position during implant. the cranial tunneler, which is an assembly of a tunneling rod, a sharp tip, and a passing tube, is intended to create a subcutaneous path for tunneling the proximal end of the lead to the intended location during implant. the medtronic model b31010 sensight? depth stop and cranial tunneler kit are components used during a lead implant procedure for a deep brain stimulation (dbs) system. the depth stop is an external device intended to retain the dbs lead position during implant. the cranial tunneler is a device intended to create a subcutaneous path for tunneling the dbs lead to the intended location during implant.

Surgical procedure kit, neurosurgical, single-use, non-medicated 澳大利亚 - 英文 - Department of Health (Therapeutic Goods Administration)

surgical procedure kit, neurosurgical, single-use, non-medicated

medtronic australasia pty ltd - 44063 - surgical procedure kit, neurosurgical, single-use, non-medicated - for use in refilling medtronic implantable programmable infusion pumps with the exception of medtronic minimed infusion pumps.

Surgical procedure kit, neurosurgical, single-use, non-medicated 澳大利亚 - 英文 - Department of Health (Therapeutic Goods Administration)

surgical procedure kit, neurosurgical, single-use, non-medicated

medtronic australasia pty ltd - 44063 - surgical procedure kit, neurosurgical, single-use, non-medicated - catheter access port (cap) kit for use in accessing the catheter via the catheter access port of medtronic implantable programmable infusion pumps with the exception of medtronic minimed infusion pumps

Epidural Needle Kit 3550-xx - Surgical procedure kit, neurosurgical, single-use, non-medicated 澳大利亚 - 英文 - Department of Health (Therapeutic Goods Administration)

epidural needle kit 3550-xx - surgical procedure kit, neurosurgical, single-use, non-medicated

medtronic australasia pty ltd - 44063 - surgical procedure kit, neurosurgical, single-use, non-medicated - the epidural needles contained in the accessory kit are designed for use with medtronic percutaneous leads for spinal cord stimulation. the needles are intended to facilitate secure placement of a percutaneous lead as part of a neurostimulation system for pain therapy.

Surgical procedure kit, neurosurgical, single-use, non-medicated 澳大利亚 - 英文 - Department of Health (Therapeutic Goods Administration)

surgical procedure kit, neurosurgical, single-use, non-medicated

integra neurosciences pty ltd - 44063 - surgical procedure kit, neurosurgical, single-use, non-medicated - two channel brain access system to be used as part of the licox brain oxygen monitoring system which measures intracranial oxygen and temperature and is intended as an adjunct monitor of trends of these parameters, indicating the perfusion status of cerebral tissue local to sensor placement. licox system values are relative within an individual, and should not be used as the sole basis for decisions as to diagnosis or therapy. it is intended to provide data additional to that obtained by current clinical practice in cases where hypoxia or ischemia are a concern.