Trinity Acetabular Shell Cementless - Acetabular shell Австралія - англійська - Department of Health (Therapeutic Goods Administration)

trinity acetabular shell cementless - acetabular shell

corin australia pty ltd - 43167 - acetabular shell - trinity acetabular shell is a modular acetabular cup system consisting of a press fit, titanium alloy shell for use with ceramic or polyethylene liners. it is coated with a titanium plasma spray and a layer of electrochemically deposited calcium phosphate. it is provided with or without screw holes permitting use of titanium bone screws for additional fixation if required. titanium occluders are optionally provided to occlude unused screw holes and an apical introducer hole, where appropriate. the trinity acetabular system is intended for use in total hip arthroplasty in skeletally mature patients, to provide increased mobility and reduce pain by replacing the damaged hip joint articulation where there is evidence of sufficient sound bone to seat and support the components.

EcoFit HA Cup cementless - Acetabular shell Австралія - англійська - Department of Health (Therapeutic Goods Administration)

ecofit ha cup cementless - acetabular shell

life healthcare pty ltd - 43167 - acetabular shell - a titanium acetabular cup designed to be press fit into the prepared acetabulum. three covered screw holes allow the use of screws for additional stability. the outer surface has a ha coating covering a titanium plasma spray which creates a roughened surface for press fit fixation against the prepared bone. the shell can accept a ceramic or a polyethylene liner. a cementless acetabular cup component used in the primary operation of the hip joint impaired by conditions such as arthrosis, rheumatoid arthritis, femoral neck fractures, avascular necrosis, or hip dysplasia.

EcoFit Cup cementless - Acetabular shell Австралія - англійська - Department of Health (Therapeutic Goods Administration)

ecofit cup cementless - acetabular shell

life healthcare pty ltd - 43167 - acetabular shell - a titanium acetabular cup designed to be press fit into the prepared acetabulum. three covered screw holes allow the use of screws for additional stability. the outer surface is coated with titanium plasma spray which creates a roughened surface for press fit fixation against the prepared bone. the shell can accept a ceramic or a polyethylene liner. a cementless acetabular cup component used in the primary operation of the hip joint impaired by conditions such as arthrosis, rheumatoid arthritis, femoral neck fractures, avascular necrosis, or hip dysplasia.

POLARCUP Shell Cemented  - Acetabular shell Австралія - англійська - Department of Health (Therapeutic Goods Administration)

polarcup shell cemented - acetabular shell

smith & nephew pty ltd - 43167 - acetabular shell - a sterile, stainless steel, cemented, acetabular shell that is implanted following acetabular reaming. the acetabulum is reamed at least two sizes larger than the implant to allow for an even cement layer. the shell is positioned by hand to avoid damage to the cement layer. the insert/ball head combination is seated onto the stem cone with an impactor and the insert/ball head unit is inserted into the shell. polarcup is indicated for advanced degeneration of the hip joint as a result of osteoarthritis, avascular necrosis, posttraumatic arthritis, or rheumatoid arthritis ? femoral neck fracture or proximal fracture of the hip joint ? conditions resulting from previous operations of the hip joint, such as failed total hip prosthesis

G7 porous plasma Bonemaster HA cementless acetabular shell  - Acetabular shell Австралія - англійська - Department of Health (Therapeutic Goods Administration)

g7 porous plasma bonemaster ha cementless acetabular shell - acetabular shell

zimmer biomet pty ltd - 43167 - acetabular shell - titanium alloy shell with titanium alloy porous plasma spray and bonemaster hydroxyapetite coating. the bonemaster ha coating creates a favourable environment for osteoblast adhesion. the shells are available in either solid shell or limited hold design, with apical plugs. the shell is packaged without a liner and requires selection of the correct liner to complete the g7 acetabular component. titanium alloy solid or limited hole acetabular shell to be used as part of the g7 acetabular system for both primary and revision applications. the titanium porous with bonemaster hydroxyapetite coating is intended for uncemented biological fixation.

G7 porous plasma cementless acetabular shell - Acetabular shell Австралія - англійська - Department of Health (Therapeutic Goods Administration)

g7 porous plasma cementless acetabular shell - acetabular shell

zimmer biomet pty ltd - 43167 - acetabular shell - titanium alloy shell with titanium alloy porous plasma spray. the shells are available in either solid shell or limited hold design, with apical plugs. the shell is packaged without a liner and requires selection of the correct liner to complete the g7 acetabular component titanium alloy solid or limited hole acetabular shell to be used as part of the g7 acetabular system for both primary and revision total hip arthroplasty applications. the titanium porous coating is intended for uncemented biological fixation.

Mpact Cementless Acetabular Shell  - Acetabular shell Австралія - англійська - Department of Health (Therapeutic Goods Administration)

mpact cementless acetabular shell - acetabular shell

medacta australia pty ltd - 43167 - acetabular shell - the acetabular shell is metallic and is designed for use in partial or total hip arthroplasty. it is fitted together as a two piece component. the mpact acetabular consists of two individual components, an acetabular shell and an associated liner. the multi hole and rim hole shells allow for the use of bone screws to provide additional fixation. the mpact acetabular shell is designed to be used in total hip arthroplasty, for primary or revision surgery.

Pinnacle Deep Profile Revision Acetabular Shell with Gription - Acetabular shell Австралія - англійська - Department of Health (Therapeutic Goods Administration)

pinnacle deep profile revision acetabular shell with gription - acetabular shell

johnson & johnson medical pty ltd t/a depuy synthes - 43167 - acetabular shell - the pinnacle deep profile revision acetabular shells with gription are titanium shells coated in gription (titanium sintered particles on a titanium sintered beads substrate) to enable biological (cementless) fixation into the prepared acetabulum. an appropriate liner is then placed into the implanted shell. the deep profile option allows the surgeon to address soft tissue laxity. the device has dome holes and 8 peripheral screw holes. the pinnacle deep profile revision acetabular shell with gription is used in cases of revision of total hip arthroplasty and is intended to provide increased patient mobility and reduce pain by replacing the damaged hip joint articulation in patients where there is evidence of sufficient sound bone to seat and support the components. total hip replacement is indicated in the following conditions: 1. a severely painful and/or disabled joint from osteoarthritis, traumatic arthritis, rheumatoid arthritis, or congenital hip dysplasia. 2. avascular necrosis of the femoral head. 3. acute traumatic fracture of the femoral head or neck. 4. failed previous hip surgery including joint reconstruction, internal fixation, arthrodesis, hemiarthroplasty, surface replacement arthroplasty, or total hip replacement. 5. certain cases of ankylosis.

Pinnacle 100 Acetabular Shell with Gription - Acetabular shell Австралія - англійська - Department of Health (Therapeutic Goods Administration)

pinnacle 100 acetabular shell with gription - acetabular shell

johnson & johnson medical pty ltd t/a depuy synthes - 43167 - acetabular shell - the pinnacle 100 acetabular shells with gription are titanium shells coated in gription to enable biological, cementless fixation into the prepared acetabulum. an appropriate liner is placed into the shell. the pinnacle 100 acetabular shell with gription is the acetabular shell component used during primary or revision total hip arthoplasty and is intended to provide increased patient mobility and reduce pain by replacing the damaged hip joint articulation in patients where there is evidence of sufficient sound bone to seat and support the components. total hip replacement is indicated in the following conditions: 1. a severely painful and/or disabled joint from osteoarthritis, traumatic arthritis, rheumatoid arthritis, or congenital hip dysplasia. 2. avascular necrosis of the femoral head. 3. acute traumatic fracture of the femoral head or neck. 4. failed previous hip surgery including joint reconstruction, internal fixation, arthrodesis, hemiarthroplasty, surface replacement arthroplasty, or total hip replacement. 5. certain cases of ankylosis.

REFLECTION INTERFIT POROUS-COATED ACETABULAR SHELL - 0/3 HOLES - Acetabular shell Австралія - англійська - Department of Health (Therapeutic Goods Administration)

reflection interfit porous-coated acetabular shell - 0/3 holes - acetabular shell

smith & nephew pty ltd - 43167 - acetabular shell - a porous coated hemispherical acetabular shell featuring a peripheral build-up. the outer rim has a cutout section which permits bone to overhang without affecting polyethylene liner seating. the shell is inserted into the acetabulum and tapped with a mallet until sealed. the apex hole is covered using watertight threaded hole cover and any unused holes, if applicable should be covered using screw hole covers. a titanium alloy porous coated acetabular shell being the outer portion of a two-piece acetabulum prosthesis intended to be used without bone cement. hip components are indicated for individuals undergoing primary and revision surgery where other treatments or devices have failed in rehabilitating hips damaged as a result of trauma or noninflammatory degenerative joint disease (nidjd) or any of its composite diagnoses of osteoarthritis, avascular necrosis, traumatic arthritis, slipped capital epiphysis, fused hip, fracture of the pelvis, and diastrophic variant. hip components are also indicated for inflammatory degenerative joint disease including rheumatoid arthritis, arthritis secondary to a variety of diseases and anomalies, and congenital dysplasia; treatments of nonunion, femoral neck fracture, and trochanteric fractures of the proximal femur with head involvement that are unmanageable using other techniques; endoprosthesis, femoral osteotomy, or girdlestone resection; fracture-dislocation of the hip; and correction of deformity.