NexGen? Complete Knee Solution Legacy?-Knee LPS-Mobile Articular Surface - Prosthesis, inter - Prosthesis, knee, internal, insert component Австралія - англійська - Department of Health (Therapeutic Goods Administration)

nexgen? complete knee solution legacy?-knee lps-mobile articular surface - prosthesis, inter - prosthesis, knee, internal, insert component

zimmer biomet pty ltd - 46585 - prosthesis, knee, internal, insert component - posterior stabilised mobile articular surface component of the nexgen lps mobile semiconstrained, nonlinked condylar mobile bearing knee prostheses system. it rotates on a highly polished trunnion on the fluted stem tibial baseplate and is manufactured from ultra-high molecular weight polyethylene (uhmwpe). it is available in multiple thicknesses to facilitate soft tissue tensioning and joint line restoration. posterior stabilised mobile articular surface component of the nexgen lps mobile semiconstrained, nonlinked condylar mobile bearing knee prostheses system indicated for use in patients with severe knee pain and disability due to: rheumatoid arthritis, osteoarthritis, traumatic arthritis, polyarthritis. collagen disorders, and/or avascular necrosis of the femoral condyle. post-traumatic loss of joint configuration, particularly when there is patellofemoral erosion, dysfunction or prior patellectomy. moderate valgus, varus, or flexion deformities. the salvage of previously failed surgical attempts or for a knee in which satisfactory stability in flexion cannot be obtained at the time of surgery.

NexGen? Complete Knee Solution Legacy? Knee LPS Femoral Component, Porous - Coated knee femur prosthesis Австралія - англійська - Department of Health (Therapeutic Goods Administration)

nexgen? complete knee solution legacy? knee lps femoral component, porous - coated knee femur prosthesis

zimmer biomet pty ltd - 33745 - coated knee femur prosthesis - the nexgen legacy ?knee lps femoral component is a porous, semi-constrained, non-linked condylar knee prosthesis made from zimaloy cobalt-chromium-molybdenum alloy intended for patients who, in the surgeon?s judgement, have adequate bone stock and varus/valgus stability, and/or when the surgeon elects to substitute for the posterior cruciate ligament. fixation method is porous fibre metal, cemented or uncemented (biological fixation). femoral component of the nexgen? complete knee solution legacy? total knee arthroplasty system indicated for patients with severe knee pain and disability due to: rheumatoid arthritis, osteoarthritis, traumatic arthritis, polyarthritis. collagen disorders, and/or avascular necrosis of the femoral condyle. post-traumatic loss of joint configuration, particularly when there is patellofemoral erosion, dysfunction or prior patellectomy. moderate valgus, varus, or flexion deformities. the salvage of previously failed surgical attempts or for a knee in which satisfactory stability in

NexGen? Complete Knee Solution, CR Articular Surface, Anterior Constrained  - Prosthesis, knee, internal, insert component Австралія - англійська - Department of Health (Therapeutic Goods Administration)

nexgen? complete knee solution, cr articular surface, anterior constrained - prosthesis, knee, internal, insert component

zimmer biomet pty ltd - 46585 - prosthesis, knee, internal, insert component - anterior constrained, cruciate ligament retaining articulating surface component of the nexgen? semiconstrained, nonlinked condylar knee prostheses system available in multiple thicknesses to facilitate soft tissue tensioning and joint line restoration. it is made from conventional ultra-high molecular weight polyethylene (uhmwpe). indicated for patients with severe knee pain and disability due to: rheumatoid arthritis, osteoarthritis, traumatic arthritis, polyarthritis. collagen disorders, and/or avascular necrosis of the femoral condyle, post-traumatic loss of joint configuration, particularly when there is patellofemoral erosion, dysfunction or prior patellectomy. moderate valgus, varus, or flexion deformities. the salvage of previously failed surgical attempts or for a knee in which satisfactory stability in flexion cannot be obtained at the time of surgery. the salvage of previously failed surgical attempts or for a knee in which satisfactory stability in flexion cannot be obtained at the time of surgery.

NexGen? Complete Knee Solution Rotating Hinge Knee Tibial Component, Precoat  - Uncoated knee tibia prosthesis, metallic Австралія - англійська - Department of Health (Therapeutic Goods Administration)

nexgen? complete knee solution rotating hinge knee tibial component, precoat - uncoated knee tibia prosthesis, metallic

zimmer biomet pty ltd - 32832 - uncoated knee tibia prosthesis, metallic - modular tibial component of the nexgen rotating hinge knee prosthesis system intended for flexion/extension and internal/external rotation between the femoral and tibial components, but is constrained in the anterior/posterior and medial/lateral directions by means of a femoral hinge post extension. tibial components are made from zimaloy? cobalt-chromium-molybdenum alloyand are for cemented use only. tibial component of the nexgen rotating hinge knee prosthesis system intended to repair or replace the tibial knee joint, for patients with mderate to severe knee instability, significant bone loss and/or ligament deficiencies caused by neoplasms, trauma, rheumatoid arthritis, osteoarthritis, traumatic arthritis, polyarthritis, collagen disorders, and/or avascular necrosis of the femoral condyle, valgus, varus, or flexion deformities, the salvage of previously failed surgical attempts.

NexGen? Complete Knee Solution Rotating Hinge Knee (RHK), Femoral Component, Option   - Uncoated knee femur prosthesis Австралія - англійська - Department of Health (Therapeutic Goods Administration)

nexgen? complete knee solution rotating hinge knee (rhk), femoral component, option - uncoated knee femur prosthesis

zimmer biomet pty ltd - 32831 - uncoated knee femur prosthesis - femoral component of the nexgen rotating hinge knee prosthesis system intended for flexion/extension and internal/external rotation between the femoral and tibial components, but is constrained in the anterior/posterior and medial/lateral directions by means of a femoral hinge post extension. manufactured from zimaloy? cobalt-chromium-molybdenum alloy. for cemented use only. femoral component of the nexgen rotating hinge knee prosthesis system intended for patients with moderate to severe knee instability, significant bone loss and/or ligament deficiencies caused by neoplasms, trauma, rheumatoid arthritis, osteoarthritis, traumatic arthritis, polyarthritis, collagen disorders, and/or avascular necrosis of the femoral condyle, valgus, varus, or flexion deformities, the salvage of previously failed surgical attempts.

NexGen? Complete Knee Solution, Fluted Stemmed Tibial Component, Option  - Uncoated knee tibia prosthesis, metallic Австралія - англійська - Department of Health (Therapeutic Goods Administration)

nexgen? complete knee solution, fluted stemmed tibial component, option - uncoated knee tibia prosthesis, metallic

zimmer biomet pty ltd - 32832 - uncoated knee tibia prosthesis, metallic - fluted stemmed plate tibial component of the nexgen semiconstrained, nonlinked condylar knee system. it is designed to be cemented not only on the proximal surface of the tibal, but around the keel of the plate as well. it is made from tivanium ti-6al-4v alloy and is for cemented use. fluted stemmed plate tibial component of the nexgen semiconstrained, nonlinked condylar knee prosthesis system intended to repair or replace the tibial knee joint, for patients with severe knee pain and disability due to: rheumatoid arthritis, osteoarthritis, traumatic arthritis, polyarthritis. collagen disorders, and/or avascular necrosis of the femoral condyle, post-traumatic loss of joint configuration, particularly when there is patellofemoral erosion, dysfunction or prior patellectomy. moderate valgus, varus, or flexion deformities. the salvage of previously failed surgical attempts or for a knee in which satisfactory stability in flexion cannot be obtained at the time of surgery.

NexGen? Complete Knee Solution, Rotating Hinge Knee, Articular Surface (With Hinge Post Extension)  - Prosthesis, knee, internal, insert component Австралія - англійська - Department of Health (Therapeutic Goods Administration)

nexgen? complete knee solution, rotating hinge knee, articular surface (with hinge post extension) - prosthesis, knee, internal, insert component

zimmer biomet pty ltd - 46585 - prosthesis, knee, internal, insert component - articular surface component of the nexgen rotating hinge knee system intended for flexion/extension and internal/external rotation between the femoral and tibial components, but is constrained in the anterior/posterior and medial/lateral directions by means of a femoral hinge post extension. it is made from ultra-high molecular-weight polyethylene, and available in multiple thicknesses to facilitate soft tissue tensioning and joint line restoration. for cemented use only. articular surface component of the nexgen rotating hinge knee system indicated for patients with moderate to severe knee instability, significant bone loss and/or ligament deficiencies caused by neoplasms, trauma, rheumatoid arthritis, osteoarthritis, traumatic arthritis, polyarthritis, collagen disorders, and/or avascular necrosis of the femoral condyle, valgus, varus, or flexion deformities, or the salvage of previously failed surgical attempts.

NexGen? Complete Knee Solution, Legacy PS LPS-Flex, (GSF) Femoral Component, Porous - Coated knee femur prosthesis Австралія - англійська - Department of Health (Therapeutic Goods Administration)

nexgen? complete knee solution, legacy ps lps-flex, (gsf) femoral component, porous - coated knee femur prosthesis

zimmer biomet pty ltd - 33745 - coated knee femur prosthesis - posterior stabilising femoral component part of the nexgen semi-constrained, non-linked condylar knee system for use when both cruciate ligaments excised and when load bearing range of motion is expected to be less than or equal to 155 degrees. designed to address specific anatomic features of the distal femur that can be seen in both male and female patients, but are typical of a female patient. manufactured from zimaloy? cobalt-chromium-molybdenum alloy. indicated for patients with severe knee pain and disability due to rheumatoid arthritis, osteoarthritis, traumatic arthritis, polyarthritis, collagen disorders, and/or avascular necrosis of the femoral condyle, post-traumatic loss of joint configuration, particularly when there is patellofemoral erosion, dysfunction or prior patellectomy, moderate valgus, varus, or flexion deformities, the salvage of previously failed surgical attempts or for a knee in which satisfactory stability in flexion cannot be obtained at the time of surgery.

NexGen? Complete Knee Solution, Stemmed Nonaugmentable Tibial Component, Option - Uncoated knee tibia prosthesis, metallic Австралія - англійська - Department of Health (Therapeutic Goods Administration)

nexgen? complete knee solution, stemmed nonaugmentable tibial component, option - uncoated knee tibia prosthesis, metallic

zimmer biomet pty ltd - 32832 - uncoated knee tibia prosthesis, metallic - stemmed nonaugmentable tibial component of the the nexgen? semiconstrained, nonlinked condylar knee system. it is made from tivanium? ti-6al-4v alloy and indicated for cemented use only. intended to repair or replace the tibial knee joint, for patients with severe knee pain and disability due to: rheumatoid arthritis, osteoarthritis, traumatic arthritis, polyarthritis. collagen disorders, and/or avascular necrosis of the femoral condyle, post-traumatic loss of joint configuration, particularly when there is patellofemoral erosion, dysfunction or prior patellectomy. moderate valgus, varus, or flexion deformities. the salvage of previously failed surgical attempts or for a knee in which satisfactory stability in flexion cannot be obtained at the time of surgery.

NexGen? Complete Knee Solution, Cruciate Retaining (CR), Pegged Tibial Component, Precoat - Uncoated knee tibia prosthesis, metallic Австралія - англійська - Department of Health (Therapeutic Goods Administration)

nexgen? complete knee solution, cruciate retaining (cr), pegged tibial component, precoat - uncoated knee tibia prosthesis, metallic

zimmer biomet pty ltd - 32832 - uncoated knee tibia prosthesis, metallic - cruciate ligament retaining (cr) precoated, pegged tibial component of the the nexgen? semiconstrained, nonlinked condylar knee system. it is made from tivanium? ti-6al-4v alloy and indicated for cemented use only. intended to repair or replace the tibial knee joint, for patients with severe knee pain and disability due to: rheumatoid arthritis, osteoarthritis, traumatic arthritis, polyarthritis. collagen disorders, and/or avascular necrosis of the femoral condyle, post-traumatic loss of joint configuration, particularly when there is patellofemoral erosion, dysfunction or prior patellectomy. moderate valgus, varus, or flexion deformities. the salvage of previously failed surgical attempts or for a knee in which satisfactory stability in flexion cannot be obtained at the time of surgery.