Laser lens, ophthalmic, surgical Аустралија - Енглески - Department of Health (Therapeutic Goods Administration)

laser lens, ophthalmic, surgical

device technologies australia pty ltd - 40238 - laser lens, ophthalmic, surgical - a patient interface lens intended to modify the convergence of an ophthalmic laser beam during diagnostic eye examinations or surgery to coagulate or cut tissues of the eye.

Endoscope accessory, filter, laser Аустралија - Енглески - Department of Health (Therapeutic Goods Administration)

endoscope accessory, filter, laser

device technologies australia pty ltd - 36308 - endoscope accessory, filter, laser - an optical laser filter used with a laser system to protect the operator's eyes from the transmitted laser energy when in use.

Eyeball fixation instrument, single-use Аустралија - Енглески - Department of Health (Therapeutic Goods Administration)

eyeball fixation instrument, single-use

device technologies australia pty ltd - 64287 - eyeball fixation instrument, single-use - fixation ring designed to provide effective immobilisation of the eyeball during ocular procedures.

8 Contact Extension Kit - Electrode/lead, stimulator, implantable, neurological Аустралија - Енглески - Department of Health (Therapeutic Goods Administration)

8 contact extension kit - electrode/lead, stimulator, implantable, neurological

boston scientific pty ltd - 44040 - neural-tissue electrical stimulation lead - the 8 contact extension kit is used to connect the dbs lead implanted in the skull to the vercise ipg implanted under the clavicle. for use in: unilateral or bilateral stimulation of the subthalamic nucleus (stn) or internal globus pallidus (gpi) for treatment of levodopa-responsive parkinson's disease which is not adequately controlled with medication; unilateral or bilateral stimulation of the internal globus pallidus (gpi) or the subthalamic nucleus (stn) for treatment of intractable primary and secondary dystonia, for persons 7 years of age and older; thalamic stimulation for the suppression of tremor not adequately controlled by medications in patients diagnosed with essential tremor. the 8 contact extension kit includes a dbs extension, torque wrench, tunneling tool shaft & tunneling tool handle.

Adhesive, <specify> Аустралија - Енглески - Department of Health (Therapeutic Goods Administration)

adhesive, <specify>

boston scientific pty ltd - 10034 - adhesive, - used to adhere the charger for an implantable pulse generator to the skin

Artisan 2 x 8 Surgical Lead - Electrode/lead, stimulator, implantable, neurological Аустралија - Енглески - Department of Health (Therapeutic Goods Administration)

artisan 2 x 8 surgical lead - electrode/lead, stimulator, implantable, neurological

boston scientific pty ltd - 44040 - neural-tissue electrical stimulation lead - the distal (paddle) end of the lead has two columns of 8 platinum electrodes which are used to deliver electrical stimulation to nerve structures within the spinal cord once the lead is implanted. the lead has two tails-each of which has 8 platinum/iridium ring contacts which enable the lead to be connected to the ipg the artisan 2 x 8 surgical lead functions as a component of the precision spinal cord stimulation system (scs) which is used in the management of chronic intractable pain. this lead delivers electrical stimulation to the nerve structures in the dorsal aspect of the spinal cord which results in inhibition of pain sensation

Cable/lead, <specify> Аустралија - Енглески - Department of Health (Therapeutic Goods Administration)

cable/lead, <specify>

boston scientific pty ltd - 35748 - cable/lead, - device used to connect two devices to each other

Cable/lead, electrosurgical unit Аустралија - Енглески - Department of Health (Therapeutic Goods Administration)

cable/lead, electrosurgical unit

boston scientific pty ltd - 35042 - cable/lead, electrosurgical unit - the or cable is used to connect the implanted leads to the external trial stimulator for intraoperative testing. the or cable transmits electrical energy from the external stimulator to the implanted lead/electrode which in turn uses this electrical energy to stimulate nerves. it works like an extension lead used to connect the sterile leads to the non-sterile stimulator. once testing is completed and the leads are performing correctly, the or cable is removed and the leads are connected to the permanently implanted pulse generator (ipg).

Catheter introducing sheath Аустралија - Енглески - Department of Health (Therapeutic Goods Administration)

catheter introducing sheath

boston scientific pty ltd - 10678 - catheter introducing sheath - the introducer is intended for the percutaneous introduction and placement of spinal cord stimulation leads.

Charger - Battery charger Аустралија - Енглески - Department of Health (Therapeutic Goods Administration)

charger - battery charger

boston scientific pty ltd - 17115 - battery charger - the charger is placed in a charging collar that is placed round the patients neck so that the charger is positioned over the stimulator implanted under the clavicle. the charger is then able to charge the rechargeable battery within the ipg to charge an implantable pulse generator which provides: unilateral or bilateral stimulation of the subthalamic nucleus (stn) or internal globus pallidus (gpi) for treatment of levodopa-responsive parkinson's disease which is not adequately controlled with medication; and/or unilateral or bilateral stimulation of the internal globus pallidus (gpi) or the subthalamic nucleus (stn) for treatment of intractable primary and secondary dystonia, for persons 7 years of age and older; and/or thalamic stimulation for the suppression of tremor not adequately controlled by medications in patients diagnosed with essential tremor.