Dextrose Monohydrate (UNII: LX22YL083G) (ANHYDROUS DEXTROSE - UNII:5SL0G7R0OK), Trisodium Citrate Dihydrate (UNII: B22547B95K) (Anhydrous Citric Acid - UNII:XF417D3PSL), Anhydrous Citric Acid (UNII: XF417D3PSL) (Anhydrous Citric Acid - UNII:XF417D3PSL), Sodium Phosphate, Monobasic, Monohydrate (UNII: 593YOG76RN) (PHOSPHATE ION - UNII:NK08V8K8HR), Adenine (UNII: JAC85A2161) (Adenine - UNII:JAC85A2161)

Доступно од:

Fenwal, Inc.

Пут администрације:

INTRAVENOUS

Тип рецептора:

PRESCRIPTION DRUG

Статус ауторизације:

New Drug Application

Карактеристике производа

                                CPDA-1 - ANTICOAGULANT CITRATE PHOSPHATE DEXTROSE ADENINE SOLUTION
FENWAL, INC.
----------
ANTICOAGULANT CITRATE PHOSPHATE DEXTROSE ADENINE SOLUTION, USP
(CPDA-1)
BLOOD-PACK™ UNIT
INSTRUCTIONS FOR BLOOD COLLECTION USING ANTICOAGULANT CITRATE
PHOSPHATE
DEXTROSE ADENINE SOLUTION, USP (CPDA-1) BLOOD-PACK™ UNITS
4R3622, 4R3626
FRESENIUS KABI
FENWAL BLOOD-PACK UNITS
RX ONLY
USING ANTICOAGULANT CITRATE PHOSPHATE DEXTROSE ADENINE SOLUTION, USP
(CPDA-1) AND FENWAL HIGHFLO NEEDLE
INSTRUCTIONS FOR USE
COLLECTION PROCEDURE:
USE ASEPTIC TECHNIQUE
NOTE: Nominal tubing dimensions of product are 0.118” inner diameter
x 0.025” wall
thickness.
NOTE: If the Y-Sampling Site is not used, donor samples may be
collected using an
alternate method following standard procedures.
PRECAUTIONS:
• DO NOT USE UNLESS THE SOLUTION IS CLEAR.
• BEFORE BEGINNING PROCEDURE, OBTAIN ONE ACCESS DEVICE FOR EACH
BLOOD-PACK
UNIT WITH Y-SAMPLING SITE TO BE PROCESSED.
1. Identify Blood-Pack unit using appropriate donor identification
system.
2. Adjust donor scale to desired collection weight and position
primary container on the
donor scale as far as possible below donor arm.
3. Clamp donor tubing between Fenwal HighFlo1 needle and primary
container. This step
may be performed prior to step 1 or 2.
4. Following blood center procedures, apply pressure to donor’s arm
and disinfect site
of venipuncture.
5. Remove needle cover per instructions below:
a) Holding the hub and cover near the tamper-evident seal, twist cover
and hub in
opposite directions to break seal.
b) Remove needle cover, being careful not to drag the cover across the
needle point.
6. Following blood center procedures, perform venipuncture,
appropriately secure
donor needle and/or tubing and release clamp on donor tubing.
7. When good blood flow is established, stabilize the front of the
needle guard to arm
with tape. (see Figure 1)
8. MIX BLOOD AND ANTICOAGULANT IN PRIMARY CONTAINER AT SEVERAL
INTERVALS DURING
COLLECTION AND IMMEDIATELY AFTER COLLECTION.
9. Collect the appropria
                                