Solia S - Lead, pacemaker, implantable, endocardial Avstralija - angleščina - Department of Health (Therapeutic Goods Administration)

solia s - lead, pacemaker, implantable, endocardial

biotronik australia pty ltd - 35223 - lead, pacemaker, implantable, endocardial - an extendable/retractable electrically active tip electrode (distal pole) fixation screw fixating the lead in the myocardium. pacing and sensing occur between the distal pole and ring electrode. a polyurethane tube improves gliding properties. a steroid (dexamethasone acetate) at the lead tip reduces inflammation and threshold increase after implantation. available in 45, 53 and 60 cm, the leads coils and cables are embedded in silicone insulation. the device is mr conditional (1.5t and 3t). solia s is for permanent transvenous implantable in the right ventricle or right atrium. for use with a suitable implantable pacemaker or icd with pacemaker functionality constituting an integrated system for permanent cardiac pacing. the electrically active screw especially suitable for positioning in the atrium and patients with deteriorating ventricular trabeculae for whom passive fixation is not possible.

Surgical screwdriver, single-use, sterile Avstralija - angleščina - Department of Health (Therapeutic Goods Administration)

surgical screwdriver, single-use, sterile

biotronik australia pty ltd - 58776 - surgical screwdriver, single-use, sterile - biotronik's fixation tool allows the user to apply rotation either retracting or extending the fixation screw of biotronik's active fixation leads. it has a spanner head which extends the screw when turning clockwise and retracts the screw when turning anti-clockwise.an accessory which is a sterile single-use device, with resterilisation and reuse prohibited.

Solia JT - Lead, pacemaker, implantable, endocardial Avstralija - angleščina - Department of Health (Therapeutic Goods Administration)

solia jt - lead, pacemaker, implantable, endocardial

biotronik australia pty ltd - 35223 - lead, pacemaker, implantable, endocardial - the lead tip has tines (polyurethane) for passive fixation in the trabeculae of the right atrium. the lead body has a j shape and consists of two coaxial coils making conduction paths for pacing and sensing between the distal pole and ring electrodes. the coils are embedded in silicone insulation. a polyurethane tube improves gliding properties. dexamethasone acetate at the lead tip reduces inflammation and threshold increase after implantation. the device is mr conditional (1.5t and 3t). solia jt is for permanent transvenous implantation in the right atrium as integrated system for long term heart pacing, when together with a suitable implantable pacemaker or icd with pacemaker functionality.

Intica Neo 7 HF-T QP - Biventricular pacemaker/defibrillator Avstralija - angleščina - Department of Health (Therapeutic Goods Administration)

intica neo 7 hf-t qp - biventricular pacemaker/defibrillator

biotronik australia pty ltd - 47270 - biventricular pacemaker/defibrillator - a triple chamber rate adaptive icd with is4 port connecting a quadripolar lv lead, home monitoring functions, max. shock of 40j and is-1/df-1/is4 connector. biocompatible titanium housing is hermetically sealed and serves as a potential antipole during shock delivery or in the case of unipolar lead configuration. ellipsoid shape facilitates implanting in the pectoral muscle area. connections for bipolar pacing, sensing, unipolar connections and shock delivery are in the header. mr conditional. intica neo 7 hf-t qp belongs to a family of implantable cardioverter-defibrillators (icds). the primary objective of the therapy is to prevent sudden cardiac death. furthermore, the device is capable of treating bradycardia arrhythmias and cardiac resynchronization therapy with multisite ventricular pacing. the implantation of an icd is a symptomatic therapy with the following objectives: ?termination of spontaneous ventricular fibrillation (vf) through shock delivery ?termination of spontaneous ventricular tachycardia

Rivacor 7 HF-T QP - Biventricular pacemaker/defibrillator Avstralija - angleščina - Department of Health (Therapeutic Goods Administration)

rivacor 7 hf-t qp - biventricular pacemaker/defibrillator

biotronik australia pty ltd - 47270 - biventricular pacemaker/defibrillator - a triple chamber rate adaptive icd, with is4 port connecting a quadripolar lv lead, home monitoring functions, max. shock of 40j and df4/is4/is-1 connector. biocompatible titanium housing is hermetically sealed and serves as a potential antipole during shock delivery or in the case of unipolar lead configuration. ellipsoid shape facilitates implanting in the pectoral muscle area. connections for bipolar pacing, sensing, unipolar connections and shock delivery are in the header. mr conditional. rivacor 7 hf-t qp belongs to a family of implantable cardioverter-defibrillators (icds). the primary objective of the therapy is to prevent sudden cardiac death. furthermore, the device is capable of treating bradycardia arrhythmias and cardiac resynchronization therapy with multisite ventricular pacing. the implantation of an icd is a symptomatic therapy with the following objectives: ?termination of spontaneous ventricular fibrillation (vf) through shock delivery ?termination of spontaneous ventricular tachycardia (vt

Intica Neo 7 HF-T - Biventricular pacemaker/defibrillator Avstralija - angleščina - Department of Health (Therapeutic Goods Administration)

intica neo 7 hf-t - biventricular pacemaker/defibrillator

biotronik australia pty ltd - 47270 - biventricular pacemaker/defibrillator - a triple chamber, rate adaptive icd with home monitoring functions, max. shock energy 40j and is-1/df-1 connector. biocompatible titanium housing is hermetically sealed and serves as a potential antipole during shock delivery or in the case of unipolar lead configuration. the ellipsoid shape facilitates implantation in the pectoral muscle area. the connections for bipolar pacing, sensing, unipolar connections and shock delivery are found in the device header. mr conditional. intica neo 7 hf-t belongs to a family of implantable cardioverter-defibrillators (icds). the primary objective of the therapy is to prevent sudden cardiac death. furthermore, the device is capable of treating bradycardia arrhythmias and cardiac resynchronization therapy with multisite ventricular pacing. the implantation of an icd is a symptomatic therapy with the following objectives: ?termination of spontaneous ventricular fibrillation (vf) through shock delivery ?termination of spontaneous ventricular tachycardia (vt) through antitachy

Intica Neo 7 DR-T - Defibrillator, implantable, automatic, dual-chamber Avstralija - angleščina - Department of Health (Therapeutic Goods Administration)

intica neo 7 dr-t - defibrillator, implantable, automatic, dual-chamber

biotronik australia pty ltd - 37265 - defibrillator, implantable, automatic, dual-chamber - a dual chamber, rate adaptive icd with home monitoring functions, max. shock energy 40j and is-1/df-1 connector. biocompatible titanium housing is hermetically sealed and serves as a potential antipole during shock delivery or in the case of unipolar lead configuration. ellipsoid shape facilitates implantation in the pectoral muscle area. the connections for bipolar pacing, sensing and shock delivery are found in the header. mr conditional. intica neo 7 dr-t belongs to a family of implantable cardioverter-defibrillators (icds). the primary objective of the therapy is to prevent sudden cardiac death. furthermore, the device is capable of treating bradycardia arrhythmias. the implantation of an icd is a symptomatic therapy with the following objectives: ?termination of spontaneous ventricular fibrillation (vf) through shock delivery ?termination of spontaneous ventricular tachycardia (vt) through antitachycardia pacing (atp); in case of ineffective atp or hemodynamically not tolerated vts, with shock delivery ?

Intica Neo 7 VR-T DX - Defibrillator, implantable, automatic Avstralija - angleščina - Department of Health (Therapeutic Goods Administration)

intica neo 7 vr-t dx - defibrillator, implantable, automatic

biotronik australia pty ltd - 35852 - defibrillator, implantable, automatic - a single chamber, rate adaptive icd with home monitoring functions, max. shock energy 40j and is-1/df-1 connector. biocompatible titanium housing is hermetically sealed and serves as a potential antipole during shock delivery or in the case of unipolar lead configuration. ellipsoid shape facilitates implantation in the pectoral muscle area. the connections for bipolar pacing, sensing and shock delivery are in the header. dx functionality also senses in the right atrium. mr conditional. intica neo 7 vr-t dx belongs to a family of implantable cardioverter-defibrillators (icd). the primary objective of the therapy is to prevent sudden cardiac death. furthermore, the device is capable of treating bradycardia arrhythmias with ventricular pacing. the implantation of an icd is a symptomatic therapy with the following objectives: ?termination of spontaneous ventricular fibrillation (vf) through shock delivery ?termination of spontaneous ventricular tachycardia (vt) through antitachycardia pacing (atp); in case of ine

Intica Neo 7 VR-T - Defibrillator, implantable, automatic Avstralija - angleščina - Department of Health (Therapeutic Goods Administration)

intica neo 7 vr-t - defibrillator, implantable, automatic

biotronik australia pty ltd - 35852 - defibrillator, implantable, automatic - a single chamber, rate adaptive icd with home monitoring functions, max. shock energy 40j and is-1/df-1 connector. biocompatible titanium housing is hermetically sealed and serves as a potential antipole during shock delivery or in the case of unipolar lead configuration. the ellipsoid shape facilitates implantation in the pectoral muscle area. the connections for bipolar pacing, sensing and shock delivery are found in the device header. mr conditional. intica neo 7 vr-t belongs to a family of implantable cardioverter-defibrillators (icds). the primary objective of the therapy is to prevent sudden cardiac death. furthermore, the device is capable of treating bradycardia arrhythmias with ventricular pacing. the implantation of an icd is a symptomatic therapy with the following objectives: ?termination of spontaneous ventricular fibrillation (vf) through shock delivery ?termination of spontaneous ventricular tachycardia (vt) through antitachycardia pacing (atp); in case of ineffective atp or hemodynamically not

Sentus ProMRI OTW QP L-xx/49 - Coronary venous pacing lead Avstralija - angleščina - Department of Health (Therapeutic Goods Administration)

sentus promri otw qp l-xx/49 - coronary venous pacing lead

biotronik australia pty ltd - 60910 - coronary venous pacing lead - implantable, steroid eluting, quadripolar, coronary sinus lead, is4 connector. the lead body consists of a coil made up of several parallel wires. the insulation is composed of silicone and is covered by a polyurethane tube which improves gliding properties. atraumatic fixation with a pre-shaped two-dimensional s-curve of the distal area. suitable for coronary vessels with an internal diameter that is larger than the lead diameter. mr conditional. in combination with a compatible implantable triple chamber pacemaker or icd, this lead is indicated for the following: ? permanent, transvenous implantation in the coronary venous system via the coronary sinus of the left side of the heart ? permanent sensing and pacing of the left ventricle