rivacor 7 vr-t - defibrillator, implantable, automatic
biotronik australia pty ltd - 35852 - defibrillator, implantable, automatic - a single chamber, rate adaptive icd with home monitoring functions, max. shock energy 40j and df4 connector. biocompatible titanium housing is hermetically sealed and serves as a potential antipole during shock delivery or in the case of unipolar lead configuration. the ellipsoid shape facilitates implantation in the pectoral muscle area. the connections for bipolar pacing, sensing and shock delivery are found in the device header. mr conditional. rivacor 7 vr-t belongs to a family of implantable cardioverter-defibrillators (icds). the primary objective of the therapy is to prevent sudden cardiac death. furthermore, the device is capable of treating bradycardia arrhythmias with ventricular pacing. the implantation of an icd is a symptomatic therapy with the following objectives: ?termination of spontaneous ventricular fibrillation (vf) through shock delivery ?termination of spontaneous ventricular tachycardia (vt) through antitachycardia pacing (atp); in case of ineffective atp or hemodynamically not tolerate
rivacor 5 vr-t - defibrillator, implantable, automatic
biotronik australia pty ltd - 35852 - defibrillator, implantable, automatic - a single chamber, rate adaptive icd with home monitoring functions, max. shock energy 40j and df4 connector. biocompatible titanium housing is hermetically sealed and serves as a potential antipole during shock delivery or in the case of unipolar lead configuration. the ellipsoid shape facilitates implantation in the pectoral muscle area. the connections for bipolar pacing, sensing and shock delivery are found in the device header. mr conditional. rivacor 5 vr-t belongs to a family of implantable cardioverter-defibrillators (icds). the primary objective of the therapy is to prevent sudden cardiac death. furthermore, the device is capable of treating bradycardia arrhythmias with ventricular pacing. the implantation of an icd is a symptomatic therapy with the following objectives: ?termination of spontaneous ventricular fibrillation (vf) through shock delivery ?termination of spontaneous ventricular tachycardia (vt) through antitachycardia pacing (atp); in case of ineffective atp or hemodynamically not tolerate
psw xxxx.y - cardiac output unit, software
biotronik australia pty ltd - 38141 - cardiac output unit, software - the software is for use with the biotronik renamic. the testing parameters include threshold; sensing (p/r measurement); retrograde conduction; intracardiac electrogram (iegm); ecg; and non-invasive programmed stimulation (nips). the programmer software is used during implantation and follow-up procedures on biotronik pacemakers, cardiac monitors and icds to carry out intraoperative tests; interrogate and program biotronik implantable cardiac monitors, pacemakers and icds.
screwdriver, surgical
biotronik australia pty ltd - 33968 - screwdriver, surgical - the torque wrench with torque control is intended for connecting biotronik leads and accessories to the is-1 and df-1 connectors of biotronik's implantable active devices (e.g. cardiac pacemakers, icds).
pacemaker /defibrillator repair kit
biotronik australia pty ltd - 33500 - pacemaker /defibrillator repair kit - the biotronik is4/df4 adapter is used to temporarily connect a lead with an is4 or df4 connector to the alligator clips on a biotronik patient cable. the adapter facilitates the correct positioning of the alligator clips and protects the is4 or df4 connector when connecting or disconnecting the patient cable.
bs df-1 - pacemaker/defibrillator port safety plug
biotronik australia pty ltd - 44900 - pacemaker/defibrillator port safety plug - the bs df-1 blind plug securely closes and seals unused df-1 connector ports in the header of active devices from biotronik. blind plug parts may have body contact. the device is mr conditional. the bs df-1 blind plug securely closes and seals unused df-1 connector ports in the header of active devices from biotronik.
bs is-1 - pacemaker/defibrillator port safety plug
biotronik australia pty ltd - 44900 - pacemaker/defibrillator port safety plug - the bs is-1 blind plug securely closes and seals unused is-1 connector ports in the header of active devices from biotronik. blind plug parts may have body contact. the device is mr conditional. the bs is-1 blind plug securely closes and seals unused is-1 connector ports in the header of active devices from biotronik.
renamic psa module - pacemaker system analyser, invasive
biotronik australia pty ltd - 36106 - pacemaker system analyser, invasive - the psa module is an expansion module for the renamic programmer and is used during implantation and follow-up of implantable pacemakers and icds (implantable cardioverter-defibrillators). renamic is equipped with a slot for insertion of the module. psa module for the renamic programmer evaluates the position and integrity of leads,& determination of appropriate pacing parameters for appropriate biotronik implanted devices (pacemaker/ icd).
stylet
biotronik australia pty ltd -
13833 - stylet,
biomonitor iii - implantable cardiac monitor
biotronik australia pty ltd - 47804 - implantable cardiac monitor - it continuously and automatically records and monitors the heart rhythm. depending on the preset parameters, subcutaneous ecgs, and other data may be recorded. the patient can also trigger the recording of subcutaneous ecgs using the remote assistant iii accessory if subjectively symptomatic episodes occur. the recordings can be transmitted to the biotronik home monitoring service center. this enables physicians to perform complete diagnosis management. mr conditional. biomonitor iii is the product name of an implantable cardiac rhythm monitoring system that records subcutaneous ecgs. recording is activated both automatically and by the patient.