Non-constrained polyethylene acetabular liner Австралия - английский - Department of Health (Therapeutic Goods Administration)

non-constrained polyethylene acetabular liner

zimmer biomet pty ltd - 43168 - non-constrained polyethylene acetabular liner - longevity cross-linked polyethylene liners are part of the trilogy acetabular system that is indicated for either cemented or uncemented use in skeletally mature individuals undergoing primary or revision surgery for rehabilitating hips damaged as a result of non-inflammatory degenerative joint disease (nidjd) or its composite diagnoses of osteoarthritis, avascular necrosis, protrusio acetabuli, traumatic arthritis, slipped capital epiphysis, fused hip, fracture of the pelvis, and diastrophic variant.

Continuum?, Trilogy? IT, Allofit? IT Acetabular Systems Longevity? Highly Crosslinked Polyethylene Liner, 7mm Offset  - Non-constrained polyethylene acetabular liner Австралия - английский - Department of Health (Therapeutic Goods Administration)

continuum?, trilogy? it, allofit? it acetabular systems longevity? highly crosslinked polyethylene liner, 7mm offset - non-constrained polyethylene acetabular liner

zimmer biomet pty ltd - 43168 - non-constrained polyethylene acetabular liner - the longevity? it 7mm offset liner is a component of the continuum?, trilogy? it, allofit? it acetabular systems. designed to lateralize the center of rotation of the acetabular cup. each liner is identified with a two letter code that corresponds to the mating acetabular shell. manufactured from longevity?, a highly crosslinked ultra-high molecular weight polyethylene (hxpe). intended for uncemented use. the longevity? it 7mm offset liner is indicated for primary or revision surgery in skeletally mature individuals for rehabilitating hips damaged as a result of noninflammatory degenerative joint disease (nidjd) or its composite diagnoses of osteoarthritis, avascular necrosis, protrusio acetabuli, traumatic arthritis, slipped capital epiphysis, fused hip, fracture of the pelvis, and diastrophic variant.

R3 XLPE Acetabular Liners - Non-constrained polyethylene acetabular liner Австралия - английский - Department of Health (Therapeutic Goods Administration)

r3 xlpe acetabular liners - non-constrained polyethylene acetabular liner

smith & nephew pty ltd - 43168 - non-constrained polyethylene acetabular liner - the sterile, cross-linked polyethylene liner is placed into an acetabular shell and seated with an impactor and mallet. it provides coverage to allow adequate joint function. hip components are indicated for individuals undergoing primary and revision surgery where other treatments or devices have failed in rehabilitating hips damaged as a result of degenerative joint disease or any of its composite diagnoses of osteoarthritis, avascular necrosis, and traumatic arthritis. hip components are also indicated for inflammatory degenerative joint disease including rheumatoid arthritis, congenital dysplasia, femoral neck fracture, and trochanteric fractures of the proximal femur with head involvement that are unmanageable using other techniques, and fracture-dislocation of the hip.

Trabecular Metal? Acetabular Revision System Longevity? Highly XLPE Revision Shell Liner, 10 Degree, Oblique  - Non-constrained polyethylene acetabular liner Австралия - английский - Department of Health (Therapeutic Goods Administration)

trabecular metal? acetabular revision system longevity? highly xlpe revision shell liner, 10 degree, oblique - non-constrained polyethylene acetabular liner

zimmer biomet pty ltd - 43168 - non-constrained polyethylene acetabular liner - the tm longevity revision shell 10 degree liner comes in an oblique configuration to provide increased lateralization and additional anteversion for stability. the liner is affixed to the tm revision shell through a 2-3mm cement mantle. contains a grooved backside which decreases stresses in cement mantle and provides rotational stability. manufactured from longevity highly crosslinked polyethylene. intended for cemented use. the trabecular metal? longevity revision shell liner is indicated for cemented use in the trabecular metal revision shell for initial placement or as an in situ replacement polyethylene bearing surface for joint instability, wear and/or damage.

Jump System Ceramic Insert Biolox Delta - Ceramic acetabular liner Австралия - английский - Department of Health (Therapeutic Goods Administration)

jump system ceramic insert biolox delta - ceramic acetabular liner

permedica australia pty ltd - 48055 - ceramic acetabular liner - biolox delta liner with an external conical shape congruent with the inner surface of the cup; fixation to the cup by means of morse-type taper. manufactured from a mix of alumina and zirconia oxide (al2o3 + zro2) and to articulate with a biolox ceramic ball head intended for ceramic on ceramic coupling. biolox delta ceramic insert to be used in primary or revision total hip replacement procedures coupled with a biolox ceramic ball head intended for ceramic on ceramic coupling. indications for use are advanced wear of the joint due to dysplasia, degenerative, post-traumatic, or rheumatic diseases, fractures or avascular necrosis, negative outcome of precedent surgeries such as joint reconstruction, osteotomies, arthrodesis, hemi-arthroplasty or total hip prosthesis.

Biolox Delta Ceramic Liner  - Ceramic acetabular liner Австралия - английский - Department of Health (Therapeutic Goods Administration)

biolox delta ceramic liner - ceramic acetabular liner

medacta australia pty ltd - 48055 - ceramic acetabular liner - the biolox delta insert is manufactured from high-purity alumina ceramic compound. the insert is fitted directly into a metal acetabular shell. the external diameter of the liner will be the same as the internal diameter of the acetabular shell implanted following the letter code; the internal diameter of the liner will be the same as the head chosen. the biolox delta insert can be used together with any biolox delta or biolox forte femoral head of suitable head diameter. the biolox delta insert is fitted directly into a metal acetabular shell in total hip joint replacement surgery. indications for use include, severly painful and/or disabled joint as a result of arthrosis, traumatic arthritis, rheumatoid polyarthritis, or congenial hip dysplasia; avascular necrosis of the femoral head; acute traumatic fracture of the femoral head or neck; failure of previous hip surgery; joint reconstruction, internal fixation, arthrodesis, partial hip arthroplasty, hip resurfacing replacement, or total hip arthroplasty.

RinglocX E1 +3MM acetabular liner  - Non-constrained polyethylene acetabular liner Австралия - английский - Department of Health (Therapeutic Goods Administration)

ringlocx e1 +3mm acetabular liner - non-constrained polyethylene acetabular liner

zimmer biomet pty ltd - 43168 - non-constrained polyethylene acetabular liner - vitamin e infused highly cross linked uhmwpe ringloc-x acetabular liner for use with an exceed ringloc-x acetabular shell. a groove around the outer liner periphery engages with a floating metal ring located in the periphery of the metal shell component, providing a liner locking mechanism. antioxidant infusion prevents oxidative polyethylene degradation. the +3mm liner lateralises the femoral head by 3mm as an alternative to a modular femoral head with longer neck. alpha-tocopherol infused highly cross linked ultra high molecular weight polyethylene acetabular liner, for use as one component of a total hip joint replacement system. the +3mm liner lateralises the femoral head by 3mm. the indications for use of acetabular liners as part of a joint replacement system include: non-inflammatory degenerative joint disease including osteoarthritis, avascular necrosis and post-traumatic arthritis; rheumatoid arthritis; correction of functional deformity; revision of failed joint reconstruction or treatment; treatment of femoral neck and trochanteric fractures of the proximal femur with femoral head involvement and which are unmanageable using other techniques.

Ringloc-X  E1 acetabular liner   - Acetabulum prosthesis - Non-constrained polyethylene acetabular liner Австралия - английский - Department of Health (Therapeutic Goods Administration)

ringloc-x e1 acetabular liner - acetabulum prosthesis - non-constrained polyethylene acetabular liner

zimmer biomet pty ltd - 43168 - non-constrained polyethylene acetabular liner - vitamin e infused highly cross linked uhmwpe ringloc-x acetabular liner for use with an exceed ringloc-x acetabular shell. a groove around the other periphery of the liner is intended to engage with a floating metal ring located in the periphery of the metal shell component, providing a liner locking mechanism. antioxidant infusion is intended to prevent oxidative degradation of the polyethylene. alpha-tocopherol infused highly cross linked ultra high molecular weight polyethylene acetabular liner, for use as one component of a total hip joint replacement system. the indications for use of acetabular liners as part of a joint replacement system include: non-inflammatory degenerative joint disease including osteoarthritis, avascular necrosis and post-traumatic arthritis; rheumatoid arthritis; correction of functional deformity; revision of failed joint reconstruction or treatment; treatment of femoral neck and trochanteric fractures of the proximal femur with femoral head involvement and which are unmanageable using other techniques.

Continuum?, Trilogy? IT, Allofit? IT Acetabular Systems Longevity? Highly Crosslinked Polyethylene Constrained Liner  - Constrained polyethylene acetabular liner Австралия - английский - Department of Health (Therapeutic Goods Administration)

continuum?, trilogy? it, allofit? it acetabular systems longevity? highly crosslinked polyethylene constrained liner - constrained polyethylene acetabular liner

zimmer biomet pty ltd - 44362 - constrained polyethylene acetabular liner - the longevity? it constrained liner, a component of the continuum?, trilogy? it and allofit? it acetabular systems, consists of a highly crosslinked ultra-high molecular weight polyethylene (uhmwpe) liner & tivanium? ti-6al-4v alloy constraining ring. it features two fingers, extending beyond the equator of the shell to mechanically capture the femoral head. the constraining ring snaps onto the liner to reinforce capture of the femoral head within the liner. indicated for uncemented use. the longevity it constrained liner is indicated as a component of a total hip prosthesis in primary or revision total hip arthroplasties where there is a high risk of hip dislocation due to a history of instability, bone loss, joint, muscle or tissue laxity, or disease condition. this device is intended for patients for whom all other options to constrained acetabular components have been considered.

Avantage E1 Acetabular liner size 66  - Non-constrained polyethylene acetabular liner Австралия - английский - Department of Health (Therapeutic Goods Administration)

avantage e1 acetabular liner size 66 - non-constrained polyethylene acetabular liner

zimmer biomet pty ltd - 43168 - non-constrained polyethylene acetabular liner - highly cross linked polyethylene acetabular insert infused with antioxidant vitamin e to neutralise residual free radicals present after irradiation process, and therefore provide resistance to oxidation. double mobility system with secondary motion occurring between insert and acetabular cup designed to help minimise risk of dislocation. vitamin e infused highly cross linked polyethylene insert intended to act as a large diameter rotating liner within the acetabular cup, providing high range of motion and decreased risk of dislocation. particularly recommended for patients of any age with high dislocation risk; pathology exposing patient to dislocation risk, e.g. neck fracture, tumour surgery, neuromuscular disorder; hip prosthesis revision especially for recurring dislocation.