OXYGEN- oxygen gas

País: Estados Unidos

Língua: inglês

Origem: NLM (National Library of Medicine)

Compre agora

Ingredientes ativos:

Oxygen (UNII: S88TT14065) (Oxygen - UNII:S88TT14065)

Disponível em:

Linde Gas & Equipment Inc.

DCI (Denominação Comum Internacional):

Oxygen

Composição:

Oxygen 99 L in 100 L

Via de administração:

RESPIRATORY (INHALATION)

Tipo de prescrição:

PRESCRIPTION DRUG

Status de autorização:

unapproved medical gas

Características técnicas

                                OXYGEN - OXYGEN GAS
LINDE GAS & EQUIPMENT INC.
_Disclaimer: This drug has not been found by FDA to be safe and
effective, and this_
_labeling has not been approved by FDA. For further information about
unapproved_
_drugs, click here._
----------
OXYGEN, COMPRESSED
WARNINGS SECTION
WARNING: For emergency use only when administered by properly trained
personnel
for oxygen deficiency and resuscitation. For all other medical
applications, RX ONLY.
Uninterrupted use of high concentrations of oxygen over a long
duration, without
monitoring its effect on oxygen content of arterial blood, may be
harmful. Do not
attempt to use on patients who have stopped breathing unless used in
conjunction with
resuscitative equipment. Patient monitoring is recommended for patient
receiving
supplemental oxygen. Flow rates for this product are approximate.
Federal law restricts
this device to sale by or on the order of a physician.
Keep out of reach and sight of children.
Federal law requires that this container be refilled with Oxygen USP
only by
establishments registered as a drug manufacturer in accordance with
the Federal _Food,_
_Drug, and Cosmetic Act._
NOTE: Keep valve minimum 12 inches (30cm) away from magnet opening. Do
not move
the package during MRI scan, as the MR data quality may be degraded.
UN-CODED SECTION
MR
MR CONDITIONAL
STATIC FIELD STRENGTH 3.0T
STATIC FIELD GRADIENT 375 GAUSS/CM
INSTRUCTIONS FOR USE
-Operating temperature -4°F to 113°F (-20°C to +45°C)
-Only use with devices intended for the product administration.
-Prepare to change the cylinder when the pointer on the gauge enters
the red area.
-to ensure the correct, prescribed flow rate, always make sure that
the flow selector is
positioned on a numbered flow setting, not between flow settings.
1) Pressure outlet (if provided)
2) Shut-off valve
3) Gauge
4) Flow outlet
5) Flow selector
BEFORE USE:
>Check gauge (3) for content.
>Check flow selector (5) is set at zero.
>Connect equipment to outlet (1 or 4).
>Slowly open shut off valve (2) fully by turning count
                                
                                Leia o documento completo
                                
                            

Pesquisar alertas relacionados a este produto