Kraj: Australia
Język: angielski
Źródło: APVMA (Australian Pesticides and Veterinary Medicines Authority)
SOYAL PHOSPHOLIPIDS; PROPIONIC ACID
NUTRIEN AG SOLUTIONS LIMITED
soyal phospholipids(350g/L)+propionic acid(350g/L)
DISPERSIBLE CONCENTRATE
SOYAL PHOSPHOLIPIDS UNGROUPED Active 350.0 g/L; PROPIONIC ACID ACID-GENERAL Active 350.0 g/L
1000L; 10L; 110L; 1L; 200L; 20L; 5L
A - Agricultural
LANDMARK OPERATIONS
HERBICIDE ADDITIVE | WETTING AGENT | ACTIVATOR | PENETRANT | POST EMERGENT HERBICIDE | SPREADER | SPREADING ADJUVANT | SURFACTAN
SURFACTANT
IMPROVE DRIFT CONTROL | IMPROVE PESTICIDE DEPOSITION | SPREADING AGENT | WETTING AGENT (USE AS DIRECTED) | IMPROVE PENETRATING PROPERTIES | IMPROVES CHEMICAL UPTAKE | IMPROVES DROPLET DEPOSITION
Poison schedule: 5; Withholding period: WITHOLDING PERIOD: N/A; Host/pest details: HERBICIDE ADDITIVE: [IMPROVE DRIFT CONTROL, IMPROVE PESTICIDE DEPOSITION, SPREADING AGENT, WETTING AGENT (USE AS DIRECTED)]; WETTING AGENT: [WETTING AGENT (USE AS DIRECTED)]; An acidifying and penetrating surfactant; reduces alkaline hydrolysis of dimethoate; assists uptake of foliar fertilisers and management of spray droplet size.
Registered
2023-07-01
GENFARM SP700 SURFACTANT Product Name: APVMA Approval No: Label Name: GENFARM SP700 SURFACTANT Signal Headings: CAUTION KEEP OUT OF REACH OF CHILDREN READ SAFETY DIRECTIONS BEFORE OPENING OR USING Constituent Statements: ACTIVE CONSTITUENTS: 350 g/L SOYAL PHOSPHOLIPIDS 350 g/L PROPIONIC ACID Mode of Action: Statement of Claims: An acidifying and penetrating surfactant Reduces Alkaline Hydrolysis of Dimethoate Assists in Uptake of Foliar Fertilisers Assists in Management of Spray Droplet Size Net Contents: 1000L 10L 110L 1L 200L 20L 5L Restraints: DO NOT use with copper products. Directions for Use: This section contains file attachment. Other Limitations: 64455 / 138580 RLP APPROVED Withholding Periods: Trade Advice: General Instructions: GENERAL INSTRUCTIONS Genfarm SP700 Surfactant can be used in general situations where the addition of a wetter/spreader or self emulsifying oil is required or recommended on the agricultural chemical label. Penetration and Wetter: Genfarm SP700 is a multi-purpose adjuvant composed of natural surfactants and penetrants derived from soybeans oils. These are combined with propionic acid to produce a penetrant, surfactant, acidifier for use with herbicides, insecticides, fungicides, foliar fertilizers and plant growth regulators. The unique properties of Genfarm SP700 enhance the uptake of many systemic herbicides, allowing them to effectively penetrate into leaves, without causing damage to non-target crop plants. Acidification: Genfarm SP700 also acts as an acidifier which will reduce pH in most cases to between 4 and 5. This reduces losses due to alkaline hydrolysis and also assists with the uptake of weak acid herbicides. Droplet size management: Genfarm SP700 will reduce the number of fine droplets (< 150 micron) produced by flat fan nozzles, without increasing the number of large spray droplets (> 400 micron). Genfarm SP700 will reduce the fine droplets associated with, but not eliminate, off target movement of the pesticide being used. This is contingent upon good agricultura Przeczytaj cały dokument
MATERIAL SAFETY DATA SHEET PRODUCT NAME: GENFARM SP700 SURFACTANT THIS REVISION ISSUED: SEPTEMBER, 2010 PAGE: 1 OF 5 Issued by: Landmark Operations Limited’ Phone: (02) 9889 5400 (business hours) POISONS INFORMATION CENTRE: 13 1126 FROM ANYWHERE IN AUSTRALIA, (0800 764 766 IN NEW ZEALAND) SECTION 1 - IDENTIFICATION OF THE MATERIAL AND SUPPLIER LANDMARK OPERATIONS LIMITED PHONE: (02) 9889 5400 SUITE 2, LEVEL 3, 64 TALAVERA ROAD FAX: (02) 9889 5411 MACQUARIE PARK, NSW, 2113 CHEMICAL NATURE: Blend of soyal phospholipids and propionic acid. TRADE NAME: GENFARM SP700 SURFACTANT PRODUCT USE: An acidifying and penetrating surfactant that reduces alkaline hydrolysis of dimethoate. CREATION DATE: DECEMBER, 2009 THIS VERSION ISSUED: SEPTEMBER, 2010 and is valid for 5 years from this date. SECTION 2 - HAZARDS IDENTIFICATION STATEMENT OF HAZARDOUS NATURE This product is classified as: C, Corrosive. Hazardous according to the criteria of SWA. Dangerous according to the Australian Dangerous Goods (ADG) Code. RISK PHRASES: R34, R37. Causes burns. Irritating to respiratory system. SAFETY PHRASES: S20, S23, S26, S28, S36, S38, S46, S24/25. When using, do not eat or drink. Do not breathe vapours or mists. In case of contact with eyes, rinse immediately with plenty of water and contact a doctor or Poisons Information Centre. After contact with skin, wash immediately with plenty of soap and water. Wear suitable protective clothing. In case of insufficient ventilation, wear suitable respiratory equipment. If swallowed, contact a doctor or Poisons Information Centre immediately and show this MSDS or label. Avoid contact with skin and eyes. SUSMP CLASSIFICATION: S5 ADG CLASSIFICATION: Class 8: Corrosive Substances. UN NUMBER: 3265, CORROSIVE LIQUID, ACIDIC, ORGANIC, N.O.S. EMERGENCY OVERVIEW PHYSICAL DESCRIPTION & COLOUR: Dark brown liquid. ODOUR: Vinegar-like odour. MAJOR HEALTH HAZARDS: causes b Przeczytaj cały dokument