Pinnacle 300 Acetabular Shell with Porocoat  - Acetabular shell Australia - engelsk - Department of Health (Therapeutic Goods Administration)

pinnacle 300 acetabular shell with porocoat - acetabular shell

johnson & johnson medical pty ltd t/a depuy synthes - 43167 - acetabular shell - the pinnacle 300 acetabular shell with porocoat are titanium shells coated in porocoat (titanium sintered beads) to enable biological fixation into the prepared acetabulum. three coated spikes located on the radius support for additional fixation. an appropriate liner is then placed into the implanted shell. the pinnacle 300 acetabular shell with porocoat is an acetabular shell used during primary or revision total hip arthroplasty and is intended to provide increased patient mobility and reduce pain by replacing the damaged hip joint articulation in patients where there is evidence of sufficient sound bone to seat and support the components. total hip replacement is indicated in the following conditions: 1. a severely painful and/or disabled joint from osteoarthritis, traumatic arthritis, rheumatoid arthritis, or congenital hip dysplasia. 2. avascular necrosis of the femoral head. 3. acute traumatic fracture of the femoral head or neck. 4. failed previous hip surgery including joint reconstruction, internal

Pinnacle 300 Acetabular Shell with Porocoat - Acetabular shell Australia - engelsk - Department of Health (Therapeutic Goods Administration)

pinnacle 300 acetabular shell with porocoat - acetabular shell

johnson & johnson medical pty ltd t/a depuy synthes - 43167 - acetabular shell - the pinnacle 300 acetabular shell with porocoat are titanium shells coated in porocoat (titanium sintered beads) to enable biological fixation into the prepared acetabulum. three coated spikes located on the radius support for additional fixation. an appropriate liner is then placed into the implanted shell. the pinnacle 300 acetabular shell with porocoat is an acetabular shell used during primary or revision total hip arthroplasty and is intended to provide increased patient mobility and reduce pain by replacing the damaged hip joint articulation in patients where there is evidence of sufficient sound bone to seat and support the components. total hip replacement is indicated in the following conditions: 1. a severely painful and/or disabled joint from osteoarthritis, traumatic arthritis, rheumatoid arthritis, or congenital hip dysplasia. 2. avascular necrosis of the femoral head. 3. acute traumatic fracture of the femoral head or neck. 4. failed previous hip surgery including joint reconstruction, internal fixation, arthrodesis, hemiarthroplasty, surface replacement arthroplasty, or total hip replacement. 5. certain cases of ankylosis. the pinnacle 300 acetabular shell with porocoat is indicated for cementless applications.

R3 Multi-hole Hemispherical Stiktite Coated Shell - Acetabular shell Australia - engelsk - Department of Health (Therapeutic Goods Administration)

r3 multi-hole hemispherical stiktite coated shell - acetabular shell

smith & nephew pty ltd - 43167 - acetabular shell - a titanium alloy (ti-6al-4v) hemispherical porous coated acetabular shell. the outer surface is coated with stiktite?, a sintered three-dimensional asymmetric titanium powder for enhanced scratch-fit feel and enhanced initial fixation. the shell has a polished inner surface to minimize backside wear. following reaming of the acetabulum, the shell is impacted into place and has multiple holes for additional screw fixation if required. the r3 multi-hole hemispherical shell is an acetabular shell component of the cementless r3 acetabular system. hip components are indicated for individuals undergoing primary and revision surgery where other treatments or devices have failed in rehabilitating hips damaged as a result of trauma or noninflammatory degenerative joint disease (nidjd) or any of its composite diagnoses of osteoarthritis, avascular necrosis, traumatic arthritis, slipped capital epiphysis, fused hip, fracture of the pelvis, and diastrophic variant. hip components are also indicated for inflammatory degenerative joint disease including rheumatoid arthritis, arthritis secondary to a variety of diseases and anomalies, and congenital dysplasia; treatments of nonunion, femoral neck fracture, and trochanteric fractures of the proximal femur with head involvement that are unmanageable using other techniques; endoprosthesis, femoral osteotomy, or girdlestone resection; fracture-dislocation of the hip; and correction of deformity.

seleXys PC shell uncemented - Acetabular shell Australia - engelsk - Department of Health (Therapeutic Goods Administration)

selexys pc shell uncemented - acetabular shell

mathys orthopaedics pty ltd - 43167 - acetabular shell - the selexys pc uncemented shell is an acetabular shell. the flattened pole area of the cup ensures load transmission near the rim of the cup. the 2mm oversizing of the cup equator enables optimum primary fixation of the implant in the acetabulum. the pure titanium pellets are sintered onto the titanium shell, creating a porous surface for osteointegration. the selexys hip system shell pc is an uncemented acetabular shell that forms part of the selexys hip system that is designed for treating diseased hip joints for primary and revision surgery.

Restoration Anatomic Shell - Acetabular shell Australia - engelsk - Department of Health (Therapeutic Goods Administration)

restoration anatomic shell - acetabular shell

stryker australia pty ltd - 43167 - acetabular shell - metal acetabular shell manufactured from titanium alloy (ti-6al-4v eli), a porous coating made of pure titanium. multiple screw hole options located in the superior and inferior regions to allow for screw fixation.an offset center of rotation ranging from 3.5mm - 8mm designed to help manage a high hip center and reproduce normal joint biomechanics. a dome hole plug is available to seal the shell. the superior area of the shell, outside of the locking mechanism, has a recessed or beveled surface. an acetabular cup intended for use in primary and revision total hip arthroplasty and are intended for cementless fixation. indicated for ;? painful, disabling joint disease of the hip resulting from: degenerative arthritis, rheumatoid arthritis, posttraumaticarthritis or late stage avascular necrosis. ? revision of previous unsuccessful femoral head replacement, cup arthroplasty or other procedure. ? clinical management problems where arthrodesis or alternative reconstructive techniques are less likely to achieve satisfactory results. ? where bone stock is of poor quality or is inadequate for other reconstructive techniques as indicated by deficiencies of the acetabulum. when used with mdm liners ? treatment of nonunion, femoral neck and trochanteric fractures of the proximal femur with head involvement that are unmanageable using other techniques. ? dislocation risks when used with constrained liners ? the trident constrained acetabular insert is indicated for use in primary and revision patients at high risk of hip dislocation due to a history of prior dislocation, bone loss, joint or soft tissue laxity, neuromuscular disease, or intraoperative instability.

Fitmore? Shells w Screw Cones - Acetabular shell Australia - engelsk - Department of Health (Therapeutic Goods Administration)

fitmore? shells w screw cones - acetabular shell

zimmer biomet pty ltd - 43167 - acetabular shell - an acetabular shell component intended to provide an articulating surface in conjuction with a liner component as part of an acetabular hip system for the treatment of degenerative diseases or trauma of the hip. it is a a cup with sharp-edged screw cones, through which insertion of cancellous screws is possible for maximising mechanical stability. the basic raw material used for manufacturing of the fitmore shells is cpti (sulmesh?-ti, protasul?-ti) fitmore shells used together with a compatible insert are indicated for uncemented use as the acetabular component in total or hemi hip arthroplasty for replacing the hip joint of patients suffering severe pain or disability (patient conditions of noninflammatory degenerative joint disease (nidjd), e.g., avascular necrosis, osteoarthritis, and inflammatory joint disease (ijd), e.g., rheumatoid arthritis; patients with failed previous surgery where pain, deformity, or dysfunction persists; revision of previously failed hip arthroplasty) provided there is an adequate bone stock to support the cementless fixation of the acetabular shell.

Trident II Tritanium Acetabular Shell - Acetabular shell Australia - engelsk - Department of Health (Therapeutic Goods Administration)

trident ii tritanium acetabular shell - acetabular shell

stryker australia pty ltd - 43167 - acetabular shell - a metal acetabular shell intended to connect with a trident acetabular bearing liner. the shells are intended for cementless fixation within the prepared acetabulum. the hex dome hole plug is an optional device which is available to help seal the trident ii shell. material: ti 6al-4v intended for cementless fixation into a prepared acetabulum for either primary or revision total hip arthroplasty. indications for use - painful, disabling joint disease of the hip resulting from: degenerative arthritis, rheumatoid arthritis, post-traumatic arthritis or late stage avascular necrosis. - revision of previous unsuccessful femoral head replacement, cup arthroplasty or other procedure. - clinical management problems where arthrodesis or alternative reconstructive techniques are less likely to achieve satisfactory results. - where bone stock is of poor quality or is inadequate for other reconstructive techniques as indicated by deficiencies of the acetabulum. when used with mdm liners - treatment of nonunion, femoral neck and trochanteric fractures of the proximal femur with head involvement that are unmanageable using other techniques. - dislocation risks when used with constrained liner - the trident constrained acetabular insert is indicated for use in primary and revision patients at high risk of hip dislocation due to a history of prior dislocation, bone loss, joint or soft tissue laxity, neuromuscular disease, or intraoperative instability.

TRINITY? PLUS ACETABULAR SHELL (CaP) - Acetabular shell Australia - engelsk - Department of Health (Therapeutic Goods Administration)

trinity? plus acetabular shell (cap) - acetabular shell

corin australia pty ltd - 43167 - acetabular shell - the trinity? plus acetabular device is a hemispherical press fit titanium alloy shell for use with ceramic, cobalt chrome alloy or polyethylene liners and a dedicated range of ceramic and cobalt chrome alloy modular 12/14 taper femoral heads. the trinity? plus acetabular system is intended for use in primary and revision tha in skeletally mature patients, to provide increased mobility and reduce pain by replacing the damaged hip joint articulation when there is evidence of sufficient sound bone to seat and support the components.

SHELLFISH AND SEAFOOD ALLERGY RELIEF- adrenalinum, belladonna, bromium, carbo animalis, colchicum autumnale, colocynthis, histam USA - engelsk - NLM (National Library of Medicine)

shellfish and seafood allergy relief- adrenalinum, belladonna, bromium, carbo animalis, colchicum autumnale, colocynthis, histam

king bio inc. - official hpus: adrenalinum, belladonna, bromium, carbo animalis, colchicum autumnale, colocynthis, histaminum hydrochloricum, hydrastis canadensis, kali carbonicum, lycopodium clavatum, mercurius solubilis, pulsatilla, urtica urens., reference image shellfishandseafoodallergyrelief.jpg - uses for temporary relief of symptoms from shellfish and seafood: - indigestion - diarrhea - nausea - sinus congestion - headaches - skin irritations - abdominal cramps uses for temporary relief of symptoms from shellfish and seafood: indigestion, diarrhea, nausea, sinus congestion, headaches, skin irritations, abdominal cramps.

DISINFECTANT DEODORANT (WATERFOS)- oystershell, nano silver liquid USA - engelsk - NLM (National Library of Medicine)

disinfectant deodorant (waterfos)- oystershell, nano silver liquid

world sung ri co., ltd - ostrea edulis shell (unii: 49oy13be7z) (ostrea edulis shell - unii:49oy13be7z), silver (unii: 3m4g523w1g) (silver - unii:3m4g523w1g) - ostrea edulis shell 20 g in 100 ml - -for indoors and air: spray the product evenly over the odor causing area, and be careful not to slip -for clothes: from a distance of 20-40cm, spray evenly on the desired area -for wallpaper: from a distance of 30cm, spray evenly to prevent crumpling