Pinnacle 100 Acetabular Shell with Duofix - Acetabular shell Australia - engelsk - Department of Health (Therapeutic Goods Administration)

pinnacle 100 acetabular shell with duofix - acetabular shell

johnson & johnson medical pty ltd t/a depuy synthes - 43167 - acetabular shell - the pinnacle 100 acetabular shells with duofix are titanium shells coated in duofix (combination of sintered titanium metal beads and hydroxyapatite) to enable biological fixation into the prepared acetabulum. an appropriate liner is then placed into the implanted shell. the pinnacle 100 acetabular shell with duofix is an acetabular shell used during primary or revision total hip arthoplasty and is intended to provide increased patient mobility and reduce pain by replacing the damaged hip joint articulation in patients where there is evidence of sufficient sound bone to seat and support the components. total hip replacement is indicated in the following conditions: 1. a severely painful and/or disabled joint from osteoarthritis, traumatic arthritis, rheumatoid arthritis, or congenital hip dysplasia. 2. avascular necrosis of the femoral head. 3. acute traumatic fracture of the femoral head or neck. 4. failed previous hip surgery including joint reconstruction, internal fixation, arthrodesis, hemiarthroplasty, surface replacement arthroplasty, or total hip replacement. 5. certain cases of ankylosis.

Pinnacle 100 Acetabular Shell with Gription - Acetabular shell Australia - engelsk - Department of Health (Therapeutic Goods Administration)

pinnacle 100 acetabular shell with gription - acetabular shell

johnson & johnson medical pty ltd t/a depuy synthes - 43167 - acetabular shell - the pinnacle 100 acetabular shells with gription are titanium shells coated in gription to enable biological, cementless fixation into the prepared acetabulum. an appropriate liner is placed into the shell. the pinnacle 100 acetabular shell with gription is the acetabular shell component used during primary or revision total hip arthroplasty and is intended to provide increased patient mobility and reduce pain by replacing the damaged hip joint articulation in patients where there is evidence of sufficient sound bone to seat and support the components. total hip replacement is indicated in the following conditions: 1. a severely painful and/or disabled joint from osteoarthritis, traumatic arthritis, rheumatoid arthritis, or congenital hip dysplasia. 2. avascular necrosis of the femoral head. 3. acute traumatic fracture of the femoral head or neck. 4. failed previous hip surgery including joint reconstruction, internal fixation, arthrodesis, hemiarthroplasty, surface replacement arthroplasty, or total hip replacement. 5. certain cases of ankylosis.

Pinnacle 100 Acetabular Shell with Porocoat - Acetabular shell Australia - engelsk - Department of Health (Therapeutic Goods Administration)

pinnacle 100 acetabular shell with porocoat - acetabular shell

johnson & johnson medical pty ltd t/a depuy synthes - 43167 - acetabular shell - the pinnacle acetabular 100 shells with porocoat are titanium shells coated in porocoat (titanium sintered beads) to enable biological fixation into the prepared acetabulum. an appropriate liner is then placed into the implanted shell. the pinnacle 100 acetabular shell with porocoat is an acetabular shell used during primary or revision total hip arthroplasty and is intended to provide increased patient mobility and reduce pain by replacing the damaged hip joint articulation in patients where there is evidence of sufficient sound bone to seat and support the components. total hip replacement is indicated in the following conditions: 1. a severely painful and/or disabled joint from osteoarthritis, traumatic arthritis, rheumatoid arthritis, or congenital hip dysplasia. 2. avascular necrosis of the femoral head. 3. acute traumatic fracture of the femoral head or neck. 4. failed previous hip surgery including joint reconstruction, internal fixation, arthrodesis, hemiarthroplasty, surface replacement arthroplasty, or total hip replacement. 5. certain cases of ankylosis.

Pinnacle 100 Acetabular Shell with Duofix - Acetabular shell Australia - engelsk - Department of Health (Therapeutic Goods Administration)

pinnacle 100 acetabular shell with duofix - acetabular shell

johnson & johnson medical pty ltd t/a depuy synthes - 43167 - acetabular shell - the pinnacle 100 acetabular shells with duofix are titanium shells coated in duofix (combination of sintered titanium metal beads and hydroxyapatite) to enable biological fixation into the prepared acetabulum. an appropriate liner is then placed into the implanted shell. the pinnacle 100 acetabular shell with duofix is an acetabular shell used during primary or revision total hip arthoplasty and is intended to provide increased patient mobility and reduce pain by replacing the damaged hip joint articulation in patients where there is evidence of sufficient sound bone to seat and support the components. total hip replacement is indicated in the following conditions: 1. a severely painful and/or disabled joint from osteoarthritis, traumatic arthritis, rheumatoid arthritis, or congenital hip dysplasia. 2. avascular necrosis of the femoral head. 3. acute traumatic fracture of the femoral head or neck. 4. failed previous hip surgery including joint reconstruction, internal fixation, arthrodesis, hemiarthroplasty, surface replacement arthroplasty, or total hip replacement. 5. certain cases of ankylosis.

Pinnacle Deep Profile Revision Acetabular Shell with Gription - Acetabular shell Australia - engelsk - Department of Health (Therapeutic Goods Administration)

pinnacle deep profile revision acetabular shell with gription - acetabular shell

johnson & johnson medical pty ltd t/a depuy synthes - 43167 - acetabular shell - the pinnacle deep profile revision acetabular shells with gription are titanium shells coated in gription (titanium sintered particles on a titanium sintered beads substrate) to enable biological (cementless) fixation into the prepared acetabulum. an appropriate liner is then placed into the implanted shell. the deep profile option allows the surgeon to address soft tissue laxity. the device has dome holes and 8 peripheral screw holes. the pinnacle deep profile revision acetabular shell with gription is used in cases of revision of total hip arthroplasty and is intended to provide increased patient mobility and reduce pain by replacing the damaged hip joint articulation in patients where there is evidence of sufficient sound bone to seat and support the components. total hip replacement is indicated in the following conditions: 1. a severely painful and/or disabled joint from osteoarthritis, traumatic arthritis, rheumatoid arthritis, or congenital hip dysplasia. 2. avascular necrosis of the femoral head. 3. acute traumatic fracture of the femoral head or neck. 4. failed previous hip surgery including joint reconstruction, internal fixation, arthrodesis, hemiarthroplasty, surface replacement arthroplasty, or total hip replacement. 5. certain cases of ankylosis.

Pinnacle Deep Profile Revision Acetabular Shell with Gription - Acetabular shell Australia - engelsk - Department of Health (Therapeutic Goods Administration)

pinnacle deep profile revision acetabular shell with gription - acetabular shell

johnson & johnson medical pty ltd t/a depuy synthes - 43167 - acetabular shell - the pinnacle deep profile revision acetabular shells with gription are titanium shells coated in gription (titanium sintered particles on a titanium sintered beads substrate) to enable biological (cementless) fixation into the prepared acetabulum. an appropriate liner is then placed into the implanted shell. the deep profile option allows the surgeon to address soft tissue laxity. the device has dome holes and 8 peripheral screw holes. the pinnacle deep profile revision acetabular shell with gription is used in cases of revision of total hip arthroplasty and is intended to provide increased patient mobility and reduce pain by replacing the damaged hip joint articulation in patients where there is evidence of sufficient sound bone to seat and support the components. total hip replacement is indicated in the following conditions: 1. a severely painful and/or disabled joint from osteoarthritis, traumatic arthritis, rheumatoid arthritis, or congenital hip dysplasia. 2. avascular necrosis of the femoral head. 3. acute traumatic fracture of the femoral head or neck. 4. failed previous hip surgery including joint reconstruction, internal fixation, arthrodesis, hemiarthroplasty, surface replacement arthroplasty, or total hip replacement. 5. certain cases of ankylosis.

Trilogy? Acetabular System Shells with CalciCoat? Ceramic Coating - Acetabular shell Australia - engelsk - Department of Health (Therapeutic Goods Administration)

trilogy? acetabular system shells with calcicoat? ceramic coating - acetabular shell

zimmer biomet pty ltd - 43167 - acetabular shell - used with an appropriate polyethylene liner to complete the acetabular component. once the metal shell has been secured in the acetabulum, the liner is locked into the shell component. the shells with screw holes permit the use of screws to provide additional fixation and security, particularly where acetabular bone stock is deficient. they are made from tivanium® ti-6al-4v alloy and is coated with calcicoat? hydroxyapatite/tricalcium phosphate (ha/tcp. the trilogy acetabular system is indicated for either cemented or uncemented use in skeletally mature individuals undergoing primary or revision surgery for rehabilitating hips damaged as a result of noninflammatory degenerative joint disease (nidjd) or its composite diagnoses of osteoarthritis, avascular necrosis, protrusio acetabuli, traumatic arthritis, slipped capital epiphysis, fused hip, fracture of the pelvis, and diastrophic variant.

Continuum? Acetabular System Trabecular Metal? Shell, with Uni-hole Porous - Acetabular shell Australia - engelsk - Department of Health (Therapeutic Goods Administration)

continuum? acetabular system trabecular metal? shell, with uni-hole porous - acetabular shell

zimmer biomet pty ltd - 43167 - acetabular shell - the tm shell is a component of the modular continuum acetabular system. the shells are made from tivanium? ti-6al-4v alloy with trabecular metal? material (tantalum) that is metallurgically bonded to the exterior of the shell. the uni-hole shell is designed for applications where no screws are desired, with a single polar dome hole to aid in shell placement and to provide visual confirmation that the shell is fully seated into the acetabulum. intended for use either with or without bone cement. the continuum tm shell is indicated for primary or revision surgery in skeletally mature individuals for rehabilitating hips damaged as a result of noninflammatory degenerative joint disease (nidjd) or its composite diagnoses of osteoarthritis, avascular necrosis, protrusion acetabuli, traumatic arthritis, slipped capital epiphysis, fused hip, fracture of the pelvis, and diastrophic variant.

G7 porous plasma Bonemaster HA cementless acetabular shell  - Acetabular shell Australia - engelsk - Department of Health (Therapeutic Goods Administration)

g7 porous plasma bonemaster ha cementless acetabular shell - acetabular shell

zimmer biomet pty ltd - 43167 - acetabular shell - titanium alloy shell with titanium alloy porous plasma spray and bonemaster hydroxyapetite coating. the bonemaster ha coating creates a favourable environment for osteoblast adhesion. the shells are available in either solid shell or limited hold design, with apical plugs. the shell is packaged without a liner and requires selection of the correct liner to complete the g7 acetabular component. titanium alloy solid or limited hole acetabular shell to be used as part of the g7 acetabular system for both primary and revision applications. the titanium porous with bonemaster hydroxyapetite coating is intended for uncemented biological fixation.

G7 porous plasma cementless acetabular shell - Acetabular shell Australia - engelsk - Department of Health (Therapeutic Goods Administration)

g7 porous plasma cementless acetabular shell - acetabular shell

zimmer biomet pty ltd - 43167 - acetabular shell - titanium alloy shell with titanium alloy porous plasma spray. the shells are available in either solid shell or limited hold design, with apical plugs. the shell is packaged without a liner and requires selection of the correct liner to complete the g7 acetabular component titanium alloy solid or limited hole acetabular shell to be used as part of the g7 acetabular system for both primary and revision total hip arthroplasty applications. the titanium porous coating is intended for uncemented biological fixation.