ACUITY Whisper View Guide Wire - Catheter guide wire Australia - engelsk - Department of Health (Therapeutic Goods Administration)

acuity whisper view guide wire - catheter guide wire

boston scientific pty ltd - 35094 - catheter guide wire - acuity whisper view? is available in 3 different support profiles (es-extra support, ds-distal support and eds-extra distal support). the distal tip is shapeable or a preshaped ?j? tip is available. after flushing to activate the hydrophilic coating, the distal end of the guide wire is inserted through the terminal pin of the lead and is advanced until the tip is just proximal to the lead tip. the guide wire/lead assembly is then advanced through a guide catheter to the desired location. boston scientific acuity whisper view guide wires with hydrophilic coating are intended to facilitate the placement of boston scientific or guidant left ventricular (lv) leads within the coronary venous vasculature

POLARx Cryoablation Balloon Catheter - Cardiac cryosurgical system catheter Australia - engelsk - Department of Health (Therapeutic Goods Administration)

polarx cryoablation balloon catheter - cardiac cryosurgical system catheter

boston scientific pty ltd - 60720 - cardiac cryosurgical system catheter - single use, sterile, flexible, uncoated over-the-wire balloon catheter designed to be positioned at the ostium of the target pulmonary vein, occlude the vessel, and deliver cryo energy to ablate cardiac tissue and interrupt electrical conduction. this catheter has a 28mm balloon of 5mm and 12mm tipped variants. cryoablation temperatures are created by a refrigerant injected from a cryo-console to the interior distal surface of the balloon segment the boston scientific cardiac cryoablation system is intended for cryoablation and electrical mapping of the pulmonary veins for pulmonary vein isolation (pvi) in the ablation treatment of paroxysmal atrial fibrillation (af). the polarx cryoablation balloon catheter is a single use, flexible, over-the-wire balloon catheter intended to ablate cardiac tissue. the boston scientific cardiac cryoablation system using the polarx cryoablation balloon catheter is indicated for the treatment of patients with drug refractory paroxysmal atrial fibrillation (paf).

POLARx FIT Cryoablation Balloon Catheter - Cardiac cryosurgical system catheter Australia - engelsk - Department of Health (Therapeutic Goods Administration)

polarx fit cryoablation balloon catheter - cardiac cryosurgical system catheter

boston scientific pty ltd - 60720 - cardiac cryosurgical system catheter - single use, sterile, flexible, over-the-wire balloon catheter designed to be positioned at the ostium of the target pulmonary vein, occlude the vessel, and deliver cryo energy to ablate cardiac tissue and interrupt electrical conduction. the balloon diameter is adjustable to either 28 or 31 mm to support treatment of a wide range of pvs. cryoablation temperatures are created by a refrigerant injected from a cryo-console to the interior distal surface of the balloon segment the boston scientific cardiac cryoablation system is intended for cryoablation and electrical mapping of the pulmonary veins for pulmonary vein isolation (pvi) in the ablation treatment of paroxysmal atrial fibrillation. the polarx fit cryoablation balloon catheter is a single use, flexible, over-the wire balloon catheter intended to ablate cardiac tissue. the boston scientific cardiac cryoablation system using the polarx fit cryoablation balloon catheter is indicated for the treatment of patients with drug refractory paroxysmal atrial fibrillation (paf).

Catheter slitter Australia - engelsk - Department of Health (Therapeutic Goods Administration)

catheter slitter

boston scientific pty ltd - 45608 - catheter slitter - universal cutter is a handheld device intended to facilitate guide catheter removal after the boston scientific or guidant coronary venous lead is positioned.

Hornet?14 Guidewire - Straight Tip - Catheter guide wire Australia - engelsk - Department of Health (Therapeutic Goods Administration)

hornet?14 guidewire - straight tip - catheter guide wire

boston scientific pty ltd - 35094 - catheter guide wire - hornet 14 guidewires with hydrophilic coating are steerable guidewires with a nominal diameter of ?0.37mm & nominal lengths of 190cm or 300cm. guidewires have a ptfe coating in proximal section; a hydrophilic coating length of 15 cm and a radiopaque length of 3.5 cm. 190cm guidewires have a 2.1cm friction fit extension section for exchange of over-the-wire systems by using stretch extension wire. 300cm guidewires allows exchange of devices without the use of an extension wire or exchange system. boston scientific hornet 14 guidewires are intended to facilitate the placement of balloon dilatation catheters or other interventional therapeutic devices during percutaneous transluminal coronary angioplasty (ptca) or other intravascular interventional procedures. these guidewires are not intended for use in the cerebral vasculature.

Hornet?10 Guidewire - Straight Tip - Catheter guide wire Australia - engelsk - Department of Health (Therapeutic Goods Administration)

hornet?10 guidewire - straight tip - catheter guide wire

boston scientific pty ltd - 35094 - catheter guide wire - hornet 10 guidewires with hydrophilic coating are steerable guidewires with a nominal diameter of ?0.37mm & nominal lengths of 190cm or 300cm. guidewires have a ptfe coating in proximal section; a hydrophilic coating length of 15 cm and a radiopaque length of 3.5 cm. 190cm guidewires have a 2.1cm friction fit extension section for exchange of over-the-wire systems by using stretch extension wire. 300cm guidewires allows exchange of devices without the use of an extension wire or exchange system. boston scientific hornet 10 guidewires are intended to facilitate the placement of balloon dilatation catheters or other interventional therapeutic devices during percutaneous transluminal coronary angioplasty (ptca)or other intravascular interventional procedures. these guidewires are not intended for use in the cerebral vasculature.

Hornet? Guidewire ? Straight Tip - Catheter guide wire Australia - engelsk - Department of Health (Therapeutic Goods Administration)

hornet? guidewire ? straight tip - catheter guide wire

boston scientific pty ltd - 35094 - catheter guide wire - hornet guidewires with hydrophilic coating are steerable guidewires with a nominal diameter of ?0.37mm & nominal lengths of 190cm or 300cm. guidewires have a ptfe coating in proximal section; a hydrophilic coating length of 15 cm and a radiopaque length of 3.5 cm. 190cm guidewires have a 2.1cm friction fit extension section for exchange of over-the-wire systems by using stretch extension wire. 300cm guidewires allows exchange of devices without the use of an extension wire or exchange system. boston scientific hornet guidewires are intended to facilitate the placement of balloon dilatation catheters or other interventional therapeutic devices during percutaneous transluminal coronary angioplasty (ptca) or other intravascular interventional procedures. these guidewires are not intended for use in the cerebral vasculature.

Samurai? RC Guidewire ? Straight Tip - Catheter guide wire Australia - engelsk - Department of Health (Therapeutic Goods Administration)

samurai? rc guidewire ? straight tip - catheter guide wire

boston scientific pty ltd - 35094 - catheter guide wire - samurai rc guidewires with hydrophilic coating are steerable guidewires available with a nominal diameter of 0.014in (?0.37mm) & in nominal lengths of 190cm or 300cm. the proximal section of the guidewires is ptfe coated. the 190cm guidewires are designed with a 2.1cm friction fit extension section for exchange of over-the-wire systems by using the stretch extension wire. the 300cm guidewire allows exchange of devices without the use of an extension wire or exchange system boston scientific samurai? rc guidewires are intended to facilitate the placement of balloon dilatation catheters or other interventional therapeutic devices during percutaneous transluminal coronary angioplasty (ptca) or other intravascular interventional procedures. these guidewires are not intended for use in the cerebral vasculature.

Samurai? Guidewire - Catheter guide wire Australia - engelsk - Department of Health (Therapeutic Goods Administration)

samurai? guidewire - catheter guide wire

boston scientific pty ltd - 35094 - catheter guide wire - samurai guidewires with hydrophilic coating are steerable guidewires available with a nominal diameter of 0.014in (?0.37mm) & in nominal lengths of 190cm or 300cm. the proximal section of the guidewires is ptfe coated. the 190cm guidewires are designed with a 2.1cm friction fit extension section for exchange of over-the-wire systems by using the stretch extension wire. the 300cm guidewire allows exchange of devices without the use of an extension wire or exchange system boston scientific samurai guidewires are intended to facilitate the placement of balloon dilatation catheters or other interventional therapeutic devices during percutaneous transluminal coronary angioplasty (ptca) or other intravascular interventional procedures. these guidewires are not intended for use in the cerebral vasculature.

Marvel? Guidewire - Catheter guide wire Australia - engelsk - Department of Health (Therapeutic Goods Administration)

marvel? guidewire - catheter guide wire

boston scientific pty ltd - 35094 - catheter guide wire - marvel guidewires with hydrophilic coating are steerable guidewires available with a nominal diameter of 0.014in (?0.37mm) & in nominal lengths of 190cm or 300cm. the proximal section of the guidewires is ptfe coated. the 190cm guidewires are designed with a 2.1cm friction fit extension section for exchange of over-the-wire systems by using the stretch extension wire. the 300cm guidewire allows exchange of devices without the use of an extension wire or exchange system boston scientific marvel? guidewires are intended to facilitate the placement of balloon dilatation catheters or other interventional therapeutic devices during percutaneous transluminal coronary angioplasty (ptca) or other intravascular interventional procedures. these guidewires are not intended for use in the cerebral vasculature.