GENUS MOBILE cementless tibial tray Co-Por - Coated knee tibia prosthesis Austrālija - angļu - Department of Health (Therapeutic Goods Administration)

genus mobile cementless tibial tray co-por - coated knee tibia prosthesis

adler ortho australia pty ltd - 34198 - coated knee tibia prosthesis - constructed from cocrmo-powder manufactured alloy with porous surface for osseointegration. features a non-anatomical shape and a posterior recess to allow retention of the pcl. contains a central hole designed to receive the central pivot of the mobile bearing platform, allowing rotational motion to occur. to ensure stability the genus tibial plate is designed with a delta-shaped tapered keel with the possibility of connecting endomedullary stems of different diameters and sizes. a tibial component of a tricompartmental rotating platform prosthesis to be used in pcl (posterior cruciate ligament) retaining/sacrificing tkr (total knee replacement) for primary and revision surgery. main indications: - primary and secondary arthrosis - rheumatoid arthritis - bone necrosis - revisions, where other devices or treatments have failed

GENUS MOBILE cemented CoCrMo tibial tray - Uncoated knee tibia prosthesis, metallic Austrālija - angļu - Department of Health (Therapeutic Goods Administration)

genus mobile cemented cocrmo tibial tray - uncoated knee tibia prosthesis, metallic

adler ortho australia pty ltd - 32832 - uncoated knee tibia prosthesis, metallic - constructed from cocrmo-casting alloy. features a non-anatomical shape and a posterior recess to allow retention of the pcl. contains a central hole designed to receive the central pivot of the mobile bearing platform, allowing rotational motion to occur. to ensure stability the genus tibial plate is designed with a delta-shaped tapered keel with the possibility of connecting endomedullary stems of different diameters and sizes. a tibial component of a tricompartmental rotating platform prosthesis to be used in pcl (posterior cruciate ligament) retaining/sacrificing tkr (total knee replacement) for primary and revision surgery. main indications: - primary and secondary arthrosis - rheumatoid arthritis - bone necrosis - revisions, where other devices or treatments have failed

GENUS cementless femoral component beads coated - Coated knee femur prosthesis Austrālija - angļu - Department of Health (Therapeutic Goods Administration)

genus cementless femoral component beads coated - coated knee femur prosthesis

adler ortho australia pty ltd - 33745 - coated knee femur prosthesis - constructed from cocrmo-casting alloy with beads coating. the genus femoral component features an anatomical shape and a constant condyle radius in the range from -70 to +90 degrees. in the last portion, the radius of the condyles reduces to increase the range of flexion. posterior condyles have a posterior inclination of 3 degrees. a femoral component of a tricompartmental rotating platform prosthesis to be used in pcl (posterior cruciate ligament) retaining/sacrificing tkr (total knee replacement) for primary and revision surgery. main indications: - primary and secondary arthrosis - rheumatoid arthritis - bone necrosis - revisions, where other devices or treatments have failed.

GENUS cemented femoral component - Uncoated knee femur prosthesis Austrālija - angļu - Department of Health (Therapeutic Goods Administration)

genus cemented femoral component - uncoated knee femur prosthesis

adler ortho australia pty ltd - 32831 - uncoated knee femur prosthesis - constructed from cocrmo-casting alloy. the genus femoral component features an anatomical shape and a constant condyle radius in the range from -70 to +90 degrees. in the last portion, the radius of the condyles reduces to increase the range of flexion. posterior condyles have a posterior inclination of 3 degrees. a femoral component of a tricompartmental rotating platform prosthesis to be used in pcl (posterior cruciate ligament)retaining/sacrificing tkr (total knee replacement) for primary and revision surgery. main indications: - primary and secondary arthrosis - rheumatoid arthritis - bone necrosis - revisions, where other devices or treatments have failed.

Parva Cementless Stem - Press-fit hip femur prosthesis, modular Austrālija - angļu - Department of Health (Therapeutic Goods Administration)

parva cementless stem - press-fit hip femur prosthesis, modular

adler ortho australia pty ltd - 55833 - press-fit hip femur prosthesis, modular - the parva stem is made of titanium alloy and features the modular neck technology which is used to optimise joint bio-mechanical joint reconstruction and stability. it has ti-por surface that maximises bone in-growth after the primary mechanical fixation. for uncemented fixation and is designed to achieve primary stability at the isthmic as well as intertrocanteric area. the parva stem is an uncemented stem that is designed to be used in hip arthroplasty for the following indications: primary and secondary coxarthrosis, avascular and post-traumatic necrosis of the femoral head, mild cdh cases and subcapital fractures of the femoral head.

CORAE Cementless HA Coated Monobloc Stem Neck - Coated hip femur prosthesis, modular Austrālija - angļu - Department of Health (Therapeutic Goods Administration)

corae cementless ha coated monobloc stem neck - coated hip femur prosthesis, modular

adler ortho australia pty ltd - 33581 - coated hip femur prosthesis, modular - forged titanium alloy implants. surface is ha coated at 80 microns +/- 20m?. available in 10 sizes with progressive dimensional growth. the first 8 sizes feature 2 offset options, to allow accurate hip biomechanics restoration. proximally the stem has several transversal parallel grooves, while distally it has longitudinal ridges. this feature maximizes bone implant contact area and improves prosthesis secondary fixation. all corae stems feature a proximal; threaded hole for axial impaction. the corae stem is a straight-tapered monoblock femoral component intended for use in primary hip replacement procedures. it is designed to connect to a suitable femoral head implant and together replace the femoral head and neck and function as part of a total hip replacement prosthesis. indicated for use in; - primary and secondary arthrosis - rheumatoid and degenerative arthritis - deformities, such as dysplasia - fractures and necrosis of bone - revisions, where other devices or treatments have failed - metastatic

Hydra Cementless Stem - HA coated - Coated hip femur prosthesis, modular Austrālija - angļu - Department of Health (Therapeutic Goods Administration)

hydra cementless stem - ha coated - coated hip femur prosthesis, modular

adler ortho australia pty ltd - 33581 - coated hip femur prosthesis, modular - part of a modular system and couples with a separate modular neck component which connects to an appropriate femoral head prosthesis. inserted into and replaces the top part of the femur as part of a hip replacement. has a double-taper profile of the metaphyseal portion to avoid risk of sinking, a quadrangular cross-section for increasing the resistance to twisting. contains horizontal grooves in the metaphyseal region and vertical grooves in the distal region to improve fixation. the hydra cementless stem which is a is a component of the modular hydra prosthesis system indicated for primary and secondary arthrosis; rheumatoid and degenerative arthritis; deformities such as dysplasia; fractures and necrosis of bone; revisions where other devices or treatments have failed and metastatic diseases.

MODULAR SLEEVE 12/14 for revision head - Femoral head/stem prosthesis adaptor Austrālija - angļu - Department of Health (Therapeutic Goods Administration)

modular sleeve 12/14 for revision head - femoral head/stem prosthesis adaptor

adler ortho australia pty ltd - 59688 - femoral head/stem prosthesis adaptor - a titanium metal adaptor sleeve with a 12/14 inner taper for use with ceramic revision femoral heads to attach the head to the trunnion of a femoral stem (or trunnion of a modular neck). a modular adaptor sleeve component combined with a ceramic revision femoral head designed to be used in total hip arthroplasty (tha)revisions. indications for use are; - primary and secondary arthrosis - rheumatoid and degenerative arthritis - deformities, such as dysplasia - fractures and necrosis of bone - revisions, where other devices or treatments have failed - metastatic diseases

MODULAR DELTA ALUMINA Ceramic Revision Head - Ceramic femoral head prosthesis Austrālija - angļu - Department of Health (Therapeutic Goods Administration)

modular delta alumina ceramic revision head - ceramic femoral head prosthesis

adler ortho australia pty ltd - 38156 - ceramic femoral head prosthesis - the modular delta alumina ceramic revision femoral head is attached to the trunnion of a femoral stem (or trunnion of a modular neck) using a modular sleeve through a 12/14 morse taper. the femoral head is ball-shaped and it is available in different diameters. once coupled with the insert the femoral head permits to restore the physiological motion of the hip joint. the modular ceramic revision femoral head is designed to be used in total hip arthroplasty (tha) revisions and to articulate with an acetabulum prosthesis. it can articulate with a ceramic inserts, polyethylene inserts and polyethylene cups. indicated for primary and secondary arthrosis, rheumatoid and degenerative arthritis, deformities, such as dysplasia, fractures and necrosis of bone, revisions, where other devices or treatments have failed and metastatic diseases.

FIXA DUPLEX Dual Mobility Cemented Cup - Acetabular shell Austrālija - angļu - Department of Health (Therapeutic Goods Administration)

fixa duplex dual mobility cemented cup - acetabular shell

adler ortho australia pty ltd - 43167 - acetabular shell - the metal cup is manufactured from m30nw stainless steel; the exterior surface is designed to maximise contact with the cement. compatible with cocrmo or ceramic heads with diameters of 22.2 mm (all sizes) or 28 mm (from size 48 upwards). hemispherical with an additional cylindrical 3 mm band. the interior of the fixa duplex cup has a mirror finish to minimise any wear to the mobile polyethylene insert. a sterile implantable acetabular component of a total hip prosthesis designed to replace the articulating surfaces of the hip in conjunction with a bipolar insert. to be used with bone cement. indicated for; - primary and secondary arthrosis - rheumatoid and degenerative arthritis - deformities, such as dysplasia - fractures and necrosis of bone - revisions, where other devices or treatments have failed - metastatic diseases