integra flowable wound matrix - wound matrix solution
integra neurosciences pty ltd -
integra valve systems (known formerly as hakim) - valve, hydrocephalic
integra neurosciences pty ltd -
integra camino flex ventricular intracranial pressure monitoring kit, vtun - catheter, neurological, ventricular
integra neurosciences pty ltd -
integra csf catheters 951 - catheter, cerebrospinal
integra neurosciences pty ltd -
pudenz flushing valve with integral connectors, with burr hole - valve, hydrocephalic
integra neurosciences pty ltd -
osv ii low pro valve - valve, hydrocephalic
integra neurosciences pty ltd - 35965 - valve, hydrocephalic - the osv ii low pro valve is a variable resistance valve which maintains a drainage rate close to the csf secretion rate. it is supplied with integral connectors. the osv ii low pro valve is a low profile implantable valve intended for controlled cerebrospinal fluid drainage from the ventricles to the peritoneal cavity or other drainage site such as the heart's right atrium; it is indicated for the treatment of patients with hydrocephalus.
licox complete brain tunneling probe kit, it2 - surgical procedure kit, neurosurgical, single-use, non-medicated
integra neurosciences pty ltd - 44063 - surgical procedure kit, neurosurgical, single-use, non-medicated - the kit consists of a parenteral probe guide with integral trocar ref vk5.2 and combined oxygen and temperature probe ref cc1.p1. the parenteral probe guide, a small diameter plastic tube with attached trocar, is designed to be ?tunneled? under the scalp and provides fixation for the cc1.p1 probe. the probe may be implanted after craniotomy through a burr or drill hole at the margin of an existing bone flap. the system is designed for no more than five days of continuous monitoring. the licox brain oxygen monitoring system measures intracranial oxygen and temperature and is intended as an adjunct monitor of trends of these parameters, indicating the perfusion status of cerebral tissue local to sensor placement. licox system values are relative within an individual, and should not be used as the sole basis for decisions as to diagnosis or therapy. it is intended to provide data additional to that obtained by current clinical practice in cases where hypoxia or ischemia are a concern
lumbar catheter accessory kit - lumbar puncture kit
integra neurosciences pty ltd - 12404 - lumbar puncture kit - the closed tip catheter is placed into the lumbar region and with a separately supplied external drainage system is used to collect cerebrospinal fluid. for external drainage of cerebrospinal fluid. for use with an integra external drainage system.
battery charger
integra neurosciences pty ltd - 17115 - battery charger - battery charger to recharge lithium batteries used with integra led headlights
battery, secondary
integra neurosciences pty ltd - 34158 - battery, secondary - rechargeable lithium batteries to be used with integra led headlight systems