FINELINE II STEROX EZ Atrial/ventricular active fixation silicone lead - Lead, pacemaker, implantable, endocardial Australia - inglese - Department of Health (Therapeutic Goods Administration)

fineline ii sterox ez atrial/ventricular active fixation silicone lead - lead, pacemaker, implantable, endocardial

boston scientific pty ltd - 35223 - lead, pacemaker, implantable, endocardial - the fineline ii sterox leads are bipolar endocardial pacing leads designed for use with implantable pulse generators for long-term cardiac pacing. a silicone rubber collar at the distal tip contains 0.75mg of dexamethasone acetate. each lead is composed of two coated conductor wires wound together to form a single conductor coil. the lead includes a silicone rubber outer insulation, irox titanium tip electrode and platinum iridium anode. the lead is intended for chronic pacing and sensing of the atrium or ventricle when used with a compatible pulse generator.

FINELINE II STEROX Ventricular passive fixation silicone lead  - Lead, pacemaker, implantable, endocardial Australia - inglese - Department of Health (Therapeutic Goods Administration)

fineline ii sterox ventricular passive fixation silicone lead - lead, pacemaker, implantable, endocardial

boston scientific pty ltd - 35223 - lead, pacemaker, implantable, endocardial - the fineline ii sterox leads are bipolar endocardial pacing leads designed for use with implantable pulse generators for long-term cardiac pacing. a silicone rubber collar at the distal tip contains 0.75mg of dexamethasone acetate. each lead is composed of two coated conductor wires wound together to form a single conductor coil. the lead includes a silicone outer insulation and fixation is achieved by silicone rubber tines. the lead is intended for chronic pacing and sensing of the ventricle when used with a compatible pulse generator.

FINELINE II STEROX EZ Atrial/ventricular active fixation polyurethane lead  - Lead, pacemaker, implantable, endocardial Australia - inglese - Department of Health (Therapeutic Goods Administration)

fineline ii sterox ez atrial/ventricular active fixation polyurethane lead - lead, pacemaker, implantable, endocardial

boston scientific pty ltd - 35223 - lead, pacemaker, implantable, endocardial - the fineline ii sterox leads are bipolar endocardial pacing leads designed for use with implantable pulse generators for long-term cardiac pacing. a silicone rubber collar at the distal tip contains 0.75mg of dexamethasone acetate. each lead is composed of two coated conductor wires wound together to form a single conductor coil. the lead includes a polyurethane outer insulation, irox titanium tip electrode and platinum iridium anode. the lead is intended for chronic pacing and sensing of the atrium or ventricle when used with a compatible pulse generator.

FINELINE II STEROX Ventricular passive fixation polyurethane lead - Lead, pacemaker, implantable, endocardial Australia - inglese - Department of Health (Therapeutic Goods Administration)

fineline ii sterox ventricular passive fixation polyurethane lead - lead, pacemaker, implantable, endocardial

boston scientific pty ltd - 35223 - lead, pacemaker, implantable, endocardial - the fineline ii sterox leads are bipolar endocardial pacing leads designed for use with implantable pulse generators for long-term cardiac pacing. a silicone rubber collar at the distal tip contains 0.75mg of dexamethasone acetate. each lead is composed of two coated conductor wires wound together to form a single conductor coil. the lead includes a polyurethane outer insulation and fixation is achieved by silicone rubber tines. the fineline ii sterox ventricular passive fixation polyurethane leads are intended for chronic pacing and sensing of the ventricle when used with a compatible generator.

FINELINE II STEROX Atrial passive fixation polyurethane lead - Lead, pacemaker, implantable, endocardial Australia - inglese - Department of Health (Therapeutic Goods Administration)

fineline ii sterox atrial passive fixation polyurethane lead - lead, pacemaker, implantable, endocardial

boston scientific pty ltd - 35223 - lead, pacemaker, implantable, endocardial - the fineline ii sterox leads are bipolar endocardial pacing leads designed for use with implantable pulse generators for long-term cardiac pacing. a silicone rubber collar at the distal tip contains 0.75mg of dexamethasone acetate. each lead is composed of two coated conductor wires wound together to form a single conductor coil. the lead includes a polyurethane outer insulation and fixation is achieved by silicone rubber tines. the lead is intended for chronic pacing and sensing of the atrium when used with a compatible pulse generator.

Cubicin Unione Europea - inglese - EMA (European Medicines Agency)

cubicin

merck sharp & dohme b.v. - daptomycin - gram-positive bacterial infections; bacteremia; soft tissue infections; endocarditis, bacterial - antibacterials for systemic use, - cubicin is indicated for the treatment of the following infections.adult and paediatric (1 to 17 years of age) patients with complicated skin and soft-tissue infections (cssti).adult patients with right-sided infective endocarditis (rie) due to staphylococcus aureus.it is recommended that the decision to use daptomycin should take into account the antibacterial susceptibility of the organism and should be based on expert advice.adult and paediatric (1 to 17 years of age) patients with staphylococcus aureus bacteraemia (sab). in adults, use in bacteraemia should be associated with rie or with cssti, while in paediatric patients, use in bacteraemia should be associated with cssti.daptomycin is active against gram positive bacteria only. in mixed infections where gram negative and/or certain types of anaerobic bacteria are suspected, cubicin should be co-administered with appropriate antibacterial agent(s). consideration should be given to official guidance on the appropriate use of antibacterial agents.

SelectSecure Model 3830 - Lead, pacemaker, implantable, endocardial Australia - inglese - Department of Health (Therapeutic Goods Administration)

selectsecure model 3830 - lead, pacemaker, implantable, endocardial

medtronic australasia pty ltd - 35223 - lead, pacemaker, implantable, endocardial - the medtronic selectsecure model 3830 steroid eluting, bipolar, implantable, non-retractable screw-in, atrial/ventricular, catheter delivered, transvenous lead is designed for pacing and sensing in the atrium or ventricle. the medtronic selectsecure model 3830 is intended for pacing and sensing in the atrium or ventricle via a cardiac vein.

Acuity X4 Straight  - Lead, pacemaker, implantable, endocardial Australia - inglese - Department of Health (Therapeutic Goods Administration)

acuity x4 straight - lead, pacemaker, implantable, endocardial

boston scientific pty ltd - 35223 - lead, pacemaker, implantable, endocardial - the acuity x4 quadripolar coronary venous leads are intended for chronic left ventricular pacing and sensing. these steroid-eluting leads have an over-the-wire design and an is41 fourpole connector. a variety of pace/sense configurations are possible with the four distal,irox-coated electrodes that can function as cathodes (all four electrodes) or anodes (all except e1, the most distal electrode) when used with a compatible pulse generator intended for chronic, left-ventricular pacing and sensing via the coronary venous system when used in conjunction with a compatible pulse generator

CapSure Sense MRI SureScan Model 4074 - Lead, pacemaker, implantable, endocardial Australia - inglese - Department of Health (Therapeutic Goods Administration)

capsure sense mri surescan model 4074 - lead, pacemaker, implantable, endocardial

medtronic australasia pty ltd - 35223 - lead, pacemaker, implantable, endocardial - steroid eluting, bipolar, implantable, tined, ventricular, transvenous lead. the model 4074 lead is intended for use in the right ventricle to monitor and regulate the patient?s heart rate by delivery of pacing therapies for the treatment of bradyarrhythmias.

CapSure Sense MRI SureScan Model 4574 - Lead, pacemaker, implantable, endocardial Australia - inglese - Department of Health (Therapeutic Goods Administration)

capsure sense mri surescan model 4574 - lead, pacemaker, implantable, endocardial

medtronic australasia pty ltd - 35223 - lead, pacemaker, implantable, endocardial - steroid eluting, bipolar, implantable, tined atrial, transvenous lead. the model 4574 lead is intended for use in the right atrium to monitor and regulate the patient?s heart rate by delivery of pacing therapies for the treatment of bradyarrhythmias