Octrode Lead Kit 3186 - Implantable lumbar neuromuscular electrical stimulation system lead Australia - inglese - Department of Health (Therapeutic Goods Administration)

octrode lead kit 3186 - implantable lumbar neuromuscular electrical stimulation system lead

abbott medical australia pty ltd - 62423 - implantable lumbar neuromuscular electrical stimulation system lead - scs uses low-intensity electrical impulses to stimulate nerve fibres within the spinal cord, often inhibiting chronic pain messages from reaching the brain. the leads are designed for introduction into the epidural space. the lead assembly consists of 8 cylindrical electrodes spaced at precise intervals. kit contains a guide wire, tunnelling tool, lead anchor, epidural needle, lead introducer and stylet. the percutaneous leads are intended to be used with abbott medical neurostimulation systems by connecting to a compatible pulse generator, either directly or with a compatible lead extension. indications for use: this neurostimulation system is indicated as an aid in the management of chronic, intractable pain of the trunk and/or limbs, including unilateral or bilateral pain associated with the following: failed back surgery syndrome and intractable low back and leg pain.

Octrode Lead Kits - Implantable lumbar neuromuscular electrical stimulation system lead Australia - inglese - Department of Health (Therapeutic Goods Administration)

octrode lead kits - implantable lumbar neuromuscular electrical stimulation system lead

abbott medical australia pty ltd - 62423 - implantable lumbar neuromuscular electrical stimulation system lead - scs uses low-intensity electrical impulses to stimulate nerve fibres within the spinal cord, often inhibiting chronic pain messages from reaching the brain. the leads are designed for introduction into the epidural space. the lead assembly consists of 8 cylindrical electrodes spaced at precise intervals. kit contains a guide wire, tunnelling tool, lead anchor, epidural needle, lead introducer and stylet. the percutaneous leads are intended to be used with abbott medical neurostimulation systems by connecting to a compatible pulse generator, either directly or with a compatible lead extension. indications for use: this neurostimulation system is indicated as an aid in the management of chronic, intractable pain of the trunk and/or limbs, including unilateral or bilateral pain associated with the following: failed back surgery syndrome and intractable low back and leg pain.

Quadra Assura CD3367-40QC - Defibrillator, implantable, automatic Australia - inglese - Department of Health (Therapeutic Goods Administration)

quadra assura cd3367-40qc - defibrillator, implantable, automatic

abbott medical australia pty ltd - 35852 - defibrillator, implantable, automatic - the quadra assura cd3367-40qc is a cardiac resynchronisation therapy device with rf telemetry and it monitors and regulates the patient?s heart rate by providing ventricular tachyarrhythmia therapy and quadripolar pacing with single site pacing. it features a df4 device header and parylene coating. the quadra assura cd3367-40qc is intended to provide ventricular antitachycardia pacing and ventricular defibrillation for automated treatment of life-threatening ventricular arrhythmias. cardiac resynchronization therapy devices (crt-ds) are also intended to resynchronize the right and left ventricles in patients with congestive heart failure. also at/af detection algorithm is indicated for detecting atrial tachyarrhythmias which have been found to be associated with an increased risk of stroke in elderly, hypertensive, pacemaker patients without prior history of af. this device is mr conditional.

Unify Assura CD3361-40 - Defibrillator, implantable, automatic Australia - inglese - Department of Health (Therapeutic Goods Administration)

unify assura cd3361-40 - defibrillator, implantable, automatic

abbott medical australia pty ltd - 35852 - defibrillator, implantable, automatic - the unify assura cd3361-40 is a cardiac resynchronisation therapy device with rf telemetry and it monitors and regulates the patient?s heart rate by providing ventricular tachyarrhythmia therapy and single site pacing. it features an is-1/df-1 device header. the unify assura cd3361-40 is intended to provide ventricular antitachycardia pacing and ventricular defibrillation for automated treatment of life-threatening ventricular arrhythmias. cardiac resynchronization therapy devices (crt-ds) are also intended to resynchronize the right and left ventricles in patients with congestive heart failure. also at/af detection algorithm is indicated for detecting atrial tachyarrhythmias which have been found to be associated with an increased risk of stroke in elderly, hypertensive, pacemaker patients without prior history of af.

Unify Assura CD3361-40Q - Defibrillator, implantable, automatic Australia - inglese - Department of Health (Therapeutic Goods Administration)

unify assura cd3361-40q - defibrillator, implantable, automatic

abbott medical australia pty ltd - 35852 - defibrillator, implantable, automatic - unify assura cd3361-40q is a cardiac resynchronisation therapy device with rf telemetry and it monitors and regulates the patient?s heart rate by providing ventricular tachyarrhythmia therapy and single site pacing. it features a df4 device header. the unify assura cd3361-40q is intended to provide ventricular antitachycardia pacing and ventricular defibrillation for automated treatment of life-threatening ventricular arrhythmias. cardiac resynchronization therapy devices (crt-ds) are also intended to resynchronize the right and left ventricles in patients with congestive heart failure. also at/af detection algorithm is indicated for detecting atrial tachyarrhythmias which have been found to be associated with an increased risk of stroke in elderly, hypertensive, pacemaker patients without prior history of af.

IsoFlex Lead Model 1944 - Lead, pacemaker, implantable, endocardial Australia - inglese - Department of Health (Therapeutic Goods Administration)

isoflex lead model 1944 - lead, pacemaker, implantable, endocardial

abbott medical australia pty ltd - 35223 - lead, pacemaker, implantable, endocardial - isoflex leads are bipolar, steroid-eluting, passive-fixation implantable pacing leads with optim insulation. isoflex model 1944t leads can be placed in the right atrium. isoflex leads are designed for use in combination with a compatible pulse generator to provide permanent pacing and sensing in either the atrium (model 1944t) or ventricle (model 1948t).

IsoFlex Lead Model 1948 - Lead, pacemaker, implantable, endocardial Australia - inglese - Department of Health (Therapeutic Goods Administration)

isoflex lead model 1948 - lead, pacemaker, implantable, endocardial

abbott medical australia pty ltd - 35223 - lead, pacemaker, implantable, endocardial - isoflex leads are bipolar, steroid-eluting, passive-fixation implantable pacing leads with optim insulation. isoflex model 1948t leads can be placed in either the right atrium or the right ventricle. isoflex? optim? leads are designed for use in combination with a compatible pulse generator to provide permanent pacing and sensing in either the atrium (model 1944t) or ventricle (model 1948t).

St Jude Medical Infinity DBS System 8CH Directional Lead - Brain electrical stimulation system, antitremor Australia - inglese - Department of Health (Therapeutic Goods Administration)

st jude medical infinity dbs system 8ch directional lead - brain electrical stimulation system, antitremor

abbott medical australia pty ltd - 37307 - brain electrical stimulation system, antitremor - leads are designed for introduction into the brain using standard stereotactic neurosurgical techniques & feature electrodes on a stiff distal end with an inactive lead tip. the proximal end contains contact bands that correspond with each of the distal electrodes & an inactive band that functions as a contact for a set screw when connecting to a compatible extension. the leads contain segmented electrodes that can be activated independently to focus stimulation in one direction. st. jude medical deep brain stimulation leads are intended to deliver stimulation to target areas in the brain. the device is mr conditional.

Cardiac mapping system reference patch Australia - inglese - Department of Health (Therapeutic Goods Administration)

cardiac mapping system reference patch

abbott medical australia pty ltd - 46007 - cardiac mapping system reference patch - for use with a cardiac mapping system in order to provide a fixed reference point for the tip of an electrophysiology catheter.