Surgical procedure kit, neurosurgical, single-use, non-medicated Australia - Inggris - Department of Health (Therapeutic Goods Administration)

surgical procedure kit, neurosurgical, single-use, non-medicated

abbott medical australia pty ltd - 44063 - surgical procedure kit, neurosurgical, single-use, non-medicated - the intended purpose is to provide a conduit for the trial lead to the trial stimulator, the implant lead or lead extension to the pulse generator, or away from the midline of the spine.

Surgical procedure kit, neurosurgical, single-use, non-medicated Australia - Inggris - Department of Health (Therapeutic Goods Administration)

surgical procedure kit, neurosurgical, single-use, non-medicated

abbott medical australia pty ltd - 44063 - surgical procedure kit, neurosurgical, single-use, non-medicated - the intended purpose is to allow the lead to be inserted percutaneously into the epidural space.

Surgical procedure kit, neurosurgical, single-use, non-medicated Australia - Inggris - Department of Health (Therapeutic Goods Administration)

surgical procedure kit, neurosurgical, single-use, non-medicated

abbott medical australia pty ltd - 44063 - surgical procedure kit, neurosurgical, single-use, non-medicated - the intended purpose is to allow the lead to be inserted percutaneously into the epidural space.

Holder, cable/lead Australia - Inggris - Department of Health (Therapeutic Goods Administration)

holder, cable/lead

abbott medical australia pty ltd - 42410 - holder, cable/lead - the header connects to external pulse generator (epg) and enables connection of trial cable(s) to the epg.

Electrosurgical diathermy system cable, single-use Australia - Inggris - Department of Health (Therapeutic Goods Administration)

electrosurgical diathermy system cable, single-use

abbott medical australia pty ltd - 47143 - electrosurgical diathermy system cable, single-use - the connector cable connects the lead or lead extension to the trial neurostimulator which is external to the body. the connector cable is external to the patient.

FlexAbility Ablation Catheter with Uni-Directional Handle, Sensor Enabled - Cardiac radio-frequency ablation system catheter Australia - Inggris - Department of Health (Therapeutic Goods Administration)

flexability ablation catheter with uni-directional handle, sensor enabled - cardiac radio-frequency ablation system catheter

abbott medical australia pty ltd - 61785 - cardiac radio-frequency ablation system catheter - catheter is made of thermoplastic elastomer material and noble metal electrodes, has a flexible tip electrode and magnetic sensor. a fluid lumen connects to open conduits at the flexible tip electrode for saline irrigation during the ablation procedure. the tip curvature is manipulated by the control mechanism located on the handle at the catheter's proximal end. to adjust the curve of the distal tip on the uni-directional catheter, push or pull the thumb control located on the handle. the flexability ablation catheter, sensor enabled is intended for use with the compatible irrigation pump and a compatible rf cardiac ablation generator. the catheter is intended for creating focal lesions during cardiac ablation procedures (mapping, stimulation, and ablation) for the treatment of arrhythmias. sensor enabled? ablation catheters are used with compatible magnetic tracking systems to enable catheter positioning and navigation. epicardial ablation should be limited to appropriately selected patients with ventricular tachycardia.

FlexAbility Ablation Catheter with Bi-Directional Handle, Sensor Enabled - Cardiac radio-frequency ablation system catheter Australia - Inggris - Department of Health (Therapeutic Goods Administration)

flexability ablation catheter with bi-directional handle, sensor enabled - cardiac radio-frequency ablation system catheter

abbott medical australia pty ltd - 61785 - cardiac radio-frequency ablation system catheter - catheter is made of thermoplastic elastomer material and noble metal electrodes, has a flexible tip electrode and magnetic sensor. a fluid lumen connects to open conduits at the flexible tip electrode for saline irrigation during the ablation procedure. the tip curvature is manipulated by the control mechanism located on the handle at the catheter's proximal end. to adjust the curve of the distal tip on the bi-directional catheter, use the actuator to deflect the catheter in either direction. the flexability ablation catheter, sensor enabled is intended for use with the compatible irrigation pump and a compatible rf cardiac ablation generator. the catheter is intended for creating focal lesions during cardiac ablation procedures (mapping, stimulation, and ablation) for the treatment of arrhythmias. sensor enabled? ablation catheters are used with compatible magnetic tracking systems to enable catheter positioning and navigation. epicardial ablation should be limited to appropriately selected patients with ventricular tachycardia.

FlexAbility Ablation Catheter with Bi-Directional Handle - Cardiac radio-frequency ablation system catheter Australia - Inggris - Department of Health (Therapeutic Goods Administration)

flexability ablation catheter with bi-directional handle - cardiac radio-frequency ablation system catheter

abbott medical australia pty ltd - 61785 - cardiac radio-frequency ablation system catheter - catheter is constructed of thermoplastic elastomer material and noble metal electrodes with a flexible tip electrode. it has fluid lumen connected to open conduits at the flexible tip electrode for saline irrigation during the ablation procedure. the tip curvature is manipulated by the control mechanism located on the handle at the catheter?s proximal end. to adjust the curve of the distal tip on the bi-directional catheter, use the actuator to deflect the catheter in either direction. the flexability ablation catheter is intended for use with the compatible irrigation pump and a compatible rf cardiac ablation generator. the catheter is intended for creating focal lesions during cardiac ablation procedures (mapping, stimulation, and ablation) for the treatment of arrhythmias. epicardial ablation should be limited to appropriately selected patients with ventricular tachycardia.

FlexAbility Ablation Catheter with Uni-Directional Handle - Cardiac radio-frequency ablation system catheter Australia - Inggris - Department of Health (Therapeutic Goods Administration)

flexability ablation catheter with uni-directional handle - cardiac radio-frequency ablation system catheter

abbott medical australia pty ltd - 61785 - cardiac radio-frequency ablation system catheter - catheter is constructed of thermoplastic elastomer material and noble metal electrodes with a flexible tip electrode. it has fluid lumen connected to open conduits at the flexible tip electrode for saline irrigation during the ablation procedure. the tip curvature is manipulated by the control mechanism located on the handle at the catheter?s proximal end. to adjust the curve of the distal tip on the catheter, push or pull the thumb control located on the handle. the flexability ablation catheter is intended for use with the compatible irrigation pump and a compatible rf cardiac ablation generator. the catheter is intended for creating focal lesions during cardiac ablation procedures (mapping, stimulation, and ablation) for the treatment of arrhythmias. epicardial ablation should be limited to appropriately selected patients with ventricular tachycardia.

Advisor HD Grid Mapping Catheter, Sensor Enabled - Electrophysiology cardiac catheter, single-use Australia - Inggris - Department of Health (Therapeutic Goods Administration)

advisor hd grid mapping catheter, sensor enabled - electrophysiology cardiac catheter, single-use

abbott medical australia pty ltd - 46355 - electrophysiology cardiac catheter, single-use - advisor hd grid mapping catheter, sensor enabled is a steerable, flexible, insulated electrophysiology catheter constructed of thermoplastic elastomer material and noble metal electrodes. the shaft curvature is manipulated by the control mechanism located on the handle at the catheter?s proximal end. to adjust the curve on the catheter, use the actuator to deflect the catheter in either direction. the advisor hd grid mapping catheter, sensor enabled, is indicated for multiple electrode electrophysiological mapping of cardiac structures in the heart, i.e., recording or stimulation only. this catheter is intended to obtain electrograms in the atrial and ventricular regions of the heart.