Link MP Reconstruction Prosthesis Stem, with Microporous surface, Cementless  - Press-fit hip femur prosthesis, modular Australia - Inggris - Department of Health (Therapeutic Goods Administration)

link mp reconstruction prosthesis stem, with microporous surface, cementless - press-fit hip femur prosthesis, modular

link orthopaedics australia pty ltd - 55833 - press-fit hip femur prosthesis, modular - a porous coated modular cementless femoral stem made from tilastan titanium alloy is designed for the revision of failed hip stems in case of extensive proximal bone loss provides distal fixation without impending bone remodelling in proximal femur. tapered fluted stems offer less stiffness. modular stem component of the mp reconstruction prosthesis is indicated for use in treatment of mobility-limiting diseases, fractures or defects of the hip joint and the proximal femur which cannot be treated by conservative or osteosynthetic procedures ? revision arthroplasty due to juxta-articular bone defects ? revision of loosened femoral prosthesis components involving extensive bone resorption of the proximal femur and widening of the medullary cavity or marked thinning of proximal femoral cortical bone ? revision of loosened femoral prosthesis components by peri-/ subprosthetic fracture ? deformed proximal femur due to fractures or osteotomies ? correction of bone deficiencies, e.g. due to tumors ? large post-revision and post-trauma segmental bone defects

Link IP UHMWPE Acetabular Cup - Polyethylene acetabulum prosthesis Australia - Inggris - Department of Health (Therapeutic Goods Administration)

link ip uhmwpe acetabular cup - polyethylene acetabulum prosthesis

link orthopaedics australia pty ltd - 34076 - polyethylene acetabulum prosthesis - functional description to: the polyethylene acetabular cup implant for cementable fixation in the acetabulum used in primary hip arthroplasty. polyethylene acetabular cups are supplied with x-ray markers for easy location on the x-ray and are suitable for use with ceramic or cocrmo heads with integrated spacers on external profile to give homogeneous cement mantle. the edge of the acetabular cup is bevelled towards the inside to improve the range of movement of the prosthesis in the cup. polyethylene acetabular cup system indicated for cementable fixation in the acetabulum in the treatment of mobility-limiting diseases, fractures or defects which cannot be treated by conservative or osteosynthetic procedures ? primary and secondary coxarthrosis ? osteoarthritis ? necrosis of the femoral head ? femoral neck fractures ? revision after implant loosening

Link Megasystem C Neck Segment, massive - Uncoated hip femur prosthesis, modular Australia - Inggris - Department of Health (Therapeutic Goods Administration)

link megasystem c neck segment, massive - uncoated hip femur prosthesis, modular

link orthopaedics australia pty ltd - 34190 - uncoated hip femur prosthesis, modular - the neck segment massive with 12/14 taper is proximal component of the assembly made from tilastan titanium alloy. the neck segment is the proximal component of the modular bone and joint revision system indicated for tumor and revision surgery as an artificial substitute for the knee stem intended to be used for mobility-limiting diseases, fractures or defects of the hip joint, the proximal and distal femur through the proximal tibia (only in combination with endo-model rotational and hinge knee sl or modular) which cannot be treated by conservative or osteosynthetic procedures. ? revision arthroplasty due to juxta-articular bone defects ? revision of loosened femoral prosthesis components involving extensive bone resorption of the proximal femur and widening of the medullary cavity or marked thinning of proximal femoral cortical bone ? revision of loosened femoral prosthesis components by peri-/ subprosthetic fracture ? deformed proximal femur due to fractures or osteotomies ? correction of bone deficiencies, e.g. due to tumors ? large post-revision and post-trauma segmental bone defects

Link Connection Component Rotational Version Rotational SL - Uncoated knee tibia prosthesis, metallic Australia - Inggris - Department of Health (Therapeutic Goods Administration)

link connection component rotational version rotational sl - uncoated knee tibia prosthesis, metallic

link orthopaedics australia pty ltd - 32832 - uncoated knee tibia prosthesis, metallic - a rotational connection component of the modular bone and joint revision system designed to articulate with an insert and the femoral prosthetic component of the knee joint. made from cocrmo and uhmwpe and is used cementless. the rotational connection component of the modular bone and joint revision system indicated for use in tumor and revision surgery for mobility-limiting diseases, fractures or defects of the hip joint, the proximal and distal femur through the proximal tibia (only in combination with endo-model rotational and hinge knee sl or modular) which cannot be treated by conservative or osteosynthetic procedures, intended to articulate with an insert and the femoral prosthetic component of the knee joint.

Link Lubinus UHMWPE Acetabular Cup Eccentric without snap fit - Polyethylene acetabulum prosthesis Australia - Inggris - Department of Health (Therapeutic Goods Administration)

link lubinus uhmwpe acetabular cup eccentric without snap fit - polyethylene acetabulum prosthesis

link orthopaedics australia pty ltd - 34076 - polyethylene acetabulum prosthesis - the polyethylene acetabular cup implant without snap fit for cementable fixation in the acetabulum used in primary hip arthroplasty. polyethylene acetabular cups are supplied with x-ray markers for easy location on the x-ray and are suitable for use with ceramic or cocrmo heads with integrated spacers on external profile to give homogeneous cement mantle polyethylene acetabular cup indicated for cementable fixation in the acetabulum in the treatment of mobility-limiting diseases, fractures or defects which cannot be treated by conservative or osteosynthetic procedures ? primary and secondary coxarthrosis ? osteoarthritis ? necrosis of the femoral head ? femoral neck fractures ? revision after implant loosening

Link Lubinus UHMWPE Acetabular Cup Eccentric with snap fit - Polyethylene acetabulum prosthesis Australia - Inggris - Department of Health (Therapeutic Goods Administration)

link lubinus uhmwpe acetabular cup eccentric with snap fit - polyethylene acetabulum prosthesis

link orthopaedics australia pty ltd - 34076 - polyethylene acetabulum prosthesis - the polyethylene acetabular cup implant with snap fit for cementable fixation in the acetabulum used in primary hip arthroplasty. polyethylene acetabular cups are supplied with x-ray markers for easy location on the x-ray and are suitable for use with ceramic or cocrmo heads with integrated spacers on external profile to give homogeneous cement mantle polyethylene acetabular cup indicated for cementable fixation in the acetabulum in the treatment of mobility-limiting diseases, fractures or defects which cannot be treated by conservative or osteosynthetic procedures ? primary and secondary coxarthrosis ? osteoarthritis ? necrosis of the femoral head ? femoral neck fractures ? revision after implant loosening

Link Coupling Component for Proximal Femur Replacement Cementless Megasystem C  - Revision uncoated hip femur prosthesis Australia - Inggris - Department of Health (Therapeutic Goods Administration)

link coupling component for proximal femur replacement cementless megasystem c - revision uncoated hip femur prosthesis

link orthopaedics australia pty ltd - 33178 - revision uncoated hip femur prosthesis - 'the cocrmo coupling component with an inner 12/14 taper is part of a modular system that is part of the proximal femur replacement. the neck is then attached to the coupling. it is made from cocrmo and uhmwpe for cementless application the modular stem segment component of the modular bone and joint revision system indicated for tumor and revision surgery for coupling proximal femur replacement mobility limiting diseases, fractures or defects of the hip joint, the proximal femur through the proximal tibia (only in combination with endo-model rotational and hinge knee sl or modular) which cannot be treated by conservative or osteosynthetic procedures.

Link Modular Stem Cementless Megasystem C  - Knee stem Australia - Inggris - Department of Health (Therapeutic Goods Administration)

link modular stem cementless megasystem c - knee stem

link orthopaedics australia pty ltd - 48066 - knee stem - the modular stem component with 12/14 taper of the modular bone and joint revision system allows partial bone replacements in the proximal and distal femur and total replacement of the femur * intraoperative flexibility using highly modular implant components * system-integrated components compatible with standard implant systems * coupling mechanics * cementless stem components made from tilastan tti6al4v. the modular stem component of the modular bone and joint revision system indicated for tumor and revision surgery as an artificial substitute for the knee stem intended to be used for mobility-limiting diseases, fractures or defects of the hip joint, the proximal and distal femur through the proximal tibia (only in combination with endo-model rotational and hinge knee sl or modular) which cannot be treated by conservative or osteosynthetic procedures. * revision arthroplasty due to juxta-articular bone defects * revision of loosened femoral prosthesis components involving extensive bone resorption of the proximal femur and widening of the medullary cavity * revision of loosened femoral prosthesis components by peri-/subprosthetic fracture * deformed proximal femur due to fractures or osteotomies * correction of bone deficiencies, e.g., due to tumors * large post-revision and post-trauma segmental bone defects oncological and revision surgery from tibial to hip area (in conjunction with rotational and hinge knee prostheses)

Link MP Reconstruction Neck Segment, without collar, Cementless, HX coated   - Coated hip femur prosthesis, modular Australia - Inggris - Department of Health (Therapeutic Goods Administration)

link mp reconstruction neck segment, without collar, cementless, hx coated - coated hip femur prosthesis, modular

link orthopaedics australia pty ltd - 33581 - coated hip femur prosthesis, modular - the neck segment is proximal component of the assembly, made from tilastan titanium alloy. neck segment body is cementless with hx that promotes bone ongrowth. proximal neck segment can be positioned for optimal ante-version. teeth at proximal stem end and inside neck segment together with fixation screw securely connect modular components. fixation mechanism allows individual ante-version for patient, regardless of position of stem within femoral canal. neck segment has 12/14 taper. the neck segment is the proximal component of the mp reconstruction prosthesis indicated for use in treatment of mobility-limiting diseases, fractures or defects of the hip joint and the proximal femur which cannot be treated by conservative or osteosynthetic procedures ? revision arthroplasty due to juxta-articular bone defects ? revision of loosened femoral prosthesis components involving extensive bone resorption of the proximal femur and widening of the medullary cavity or marked thinning of proximal femoral cortical bone ? revision of loosened femoral prosthesis components by peri-/ subprosthetic fracture ? deformed proximal femur due to fractures or osteotomies ? correction of bone deficiencies, e.g. due to tumors ? large post-revision and post-trauma segmental bone defects

Link Femoral component Intracondylar with patellar flange Modular Cementable Rotational Knee SL  - Revision uncoated hip femur prosthesis Australia - Inggris - Department of Health (Therapeutic Goods Administration)

link femoral component intracondylar with patellar flange modular cementable rotational knee sl - revision uncoated hip femur prosthesis

link orthopaedics australia pty ltd - 33178 - revision uncoated hip femur prosthesis - the femoral intracondylar component with patellar flange of the modular bone and joint revision system allows partial bone replacements in the proximal and distal femur in small increments and total replacement of the femur. made from cocrmo uhmwpe and is cementable. the femoral component of the modular bone and joint revision system indicated for use in tumor and revision surgery intended to be used for mobility-limiting diseases, fractures or defects of the hip joint, the proximal and distal femur through the proximal tibia (only in combination with endo-model rotational and hinge knee sl or modular) which cannot be treated by conservative or osteosynthetic procedures. * revision arthroplasty due to juxta-articular bone defects * revision of loosened femoral prosthesis components involving extensive bone resorption of the proximal femur and widening of the medullary cavity * revision of loosened femoral prosthesis components by peri-/subprosthetic fracture * deformed proximal femur due to fractures or osteotomies * correction of bone deficiencies, e.g. due to tumors * large post-revision and post-trauma segmental bone defects oncological and revision surgery from tibial to hip area (in conjunction with rotational and hinge knee prostheses)