multibic potassium-free, solution for haemofiltration
fresenius medical care australia pty ltd - magnesium chloride hexahydrate, quantity: 0.1017 g/l; sodium bicarbonate, quantity: 2.94 g/l; sodium chloride, quantity: 6.136 g/l; glucose monohydrate, quantity: 1.1 g/l (equivalent: glucose, qty 1 g/l); calcium chloride dihydrate, quantity: 0.2205 g/l - solution, dialysis - excipient ingredients: carbon dioxide; water for injections; hydrochloric acid; monobasic sodium phosphate dihydrate - replacement fluid, which is administered intravenously in patients with acute renal failure in intensive care units.
multibic 4 mmol/l potassium, solution for haemofiltration
fresenius medical care australia pty ltd - glucose monohydrate, quantity: 1.1 g/l (equivalent: glucose, qty 1 g/l); sodium bicarbonate, quantity: 2.94 g/l; magnesium chloride hexahydrate, quantity: 0.1017 g/l; calcium chloride dihydrate, quantity: 0.2205 g/l; sodium chloride, quantity: 6.136 g/l; potassium chloride, quantity: 0.2982 g/l - solution, dialysis - excipient ingredients: water for injections; hydrochloric acid; carbon dioxide; monobasic sodium phosphate dihydrate - replacement fluid, which is administered intravenously in patients with acute renal failure in intensive care units.
cyclogest progesterone 400 mg pessary strip pack
gedeon richter australia pty ltd - progesterone, quantity: 400 mg - pessary - excipient ingredients: hard fat - cyclogest is indicated for luteal phase support as part of an assisted reproductive technology (art) treatment for women.
equivac tat 1500iu/ml tetanus antitoxin
zoetis australia pty ltd - clostridium tetani - antitoxin; phenol - misc. vaccines or anti sera - clostridium tetani - antitoxin vaccine-toxoid active 1500.0 iu/ml; phenol phenol other 2.2 mg/ml - immunotherapy - calf | cattle | dog | goat | horse | horse foal | lamb | pig - piglet | pigs | sheep | beef | beef calf | billy | bitch | boar | - tetanus | tetanus vaccination
pulse oximeter, battery-powered
rapp australia pty ltd - 45607 - pulse oximeter, battery-powered - this device is applied to a body site, eg finger, ear, bridge of nose or foot of paediatric or adult patient, in order to transmit light through the skin to be absorbed by the oxyhaemoglobin and deoxyhaemoglobin, in the arterial tissue blood. signals are received by the parent device which displays the results. this device is reusable.
stretcher, orthopaedic
rapp australia pty ltd - 35570 - stretcher, orthopaedic - device designed to assist in picking up a patient by using a rigid stretcher that can divide into to parts or hinge at either end to facilitate placing the stretcher under the patient whilst causing minimal movement
tubing, <specify>
rapp australia pty ltd -
14238 - tubing,
inflator, tracheal tube cuff
rapp australia pty ltd - 35401 - inflator, tracheal tube cuff - this device is used to inflate cuffs of tracheal tubes, supragloticc/laryngeal airways or similar cuffed devices when they are in situ. it has a pressure manometer that shows the pressure to the user in order to prevent excessive amounts of air in the cuff which will cause trauma. it is a multi use product.
suction unit, gas powered
rapp australia pty ltd - 36607 - suction unit, gas powered - used in the removal of fluids and/or particulate matter from a patient airway, via aspiration. the device produces negative pressure and is powered by pressurized gases, air or oxygen, being forced through a venturi. it is typically used bedside, in operating theatres, on anaesthesia units or in out of hospital emergency resuscitation.
oxygen cylinder regulator
rapp australia pty ltd - 43438 - oxygen cylinder regulator - a reduction valve designed to be attached via a pin indexed gastight connector to the valve stem of a cylinder filled with oxygen, to reduce the cylinders high variable gas pressure (e.g., 50 - 250 bar) to a lower, constant working pressure, typically 3 - 5 bar. it can be a single or a dual stage regulator, of a piston or diaphragm design. it has a safety relief valve to avoid excessive pressure, it has a manometer to display the available gas reserve of a gas cylinder, some models have an integrated flow control device to provide controlled gas flow generally in the ranges of 0.25 lpm to 25 lpm to allow administration of oxygen therapy or connection to a resuscitation bag (bvm). some models also have a low pressure outlet/s, typically 4 bar, to allow the connection of gas driven devices such as, for example, a suction unit and/or ventilator.