Medacta Shoulder System Glenoid Baseplate Pegged - Reverse shoulder prosthesis base plate Ավստրալիա - անգլերեն - Department of Health (Therapeutic Goods Administration)

medacta shoulder system glenoid baseplate pegged - reverse shoulder prosthesis base plate

medacta australia pty ltd - 48091 - reverse shoulder prosthesis base plate - the glenoid baseplate is intended to be fixed on the glenoid bone by means of a central press-fit and with the help of glenoid polyaxial screws (locking or non-locking). the glenosphere is intended to be assembled with the glenoid baseplate by means of a taper morse connection and secured by the glenosphere screw. the ?22 and ?24.5 baseplates have 2 spherical holes for the glenoid polyaxial locking screws, while the ?27 has 4 spherical seats, and the central post is available in three lengths. device indicated for treatment of humeral fractures and for primary or revision total shoulder replacement in patients with a grossly rotator cuff deficient shoulder joint with severe arthropathy or a previously failed joint replacement. the patient?s joint must be anatomically and structurally suited to receive the selected implant(s), and a functional deltoid muscle is necessary to use the device. the glenoid baseplate is intended for cementless application with the addition of screws for fixation.

Medacta Shoulder System Glenoid Polyaxial Screw - Shoulder prosthesis screw Ավստրալիա - անգլերեն - Department of Health (Therapeutic Goods Administration)

medacta shoulder system glenoid polyaxial screw - shoulder prosthesis screw

medacta australia pty ltd - 48094 - shoulder prosthesis screw - device manufactured from titanium alloy and enhanced with type-ii anodization. they are designed to aid fixation of the glenoid baseplate to bone. device intended for use as a hemi or total shoulder replacement. it is a single-use device for the reconstruction of the gleno-humeral joint in case of osteoarthritis, rheumatoid arthritis, traumatic arthritis, avascular necrosis as well as complex fractures, post-traumatic malunion and revision of failed arthroplasty in patients with an intact or reparable rotator cuff shoulder joint. the humeral components are for cemented and cementless use.

Medacta Shoulder System Glenosphere - Reverse shoulder prosthesis head Ավստրալիա - անգլերեն - Department of Health (Therapeutic Goods Administration)

medacta shoulder system glenosphere - reverse shoulder prosthesis head

medacta australia pty ltd - 48093 - reverse shoulder prosthesis head - the glenosphere is attached to the glenoid baseplate and secured by a taper connection and a fastening screw. the centre of the glenosphere is located at 4 or 9mm lateral to the deepest point of the reamed glenoid vault, while the inferior eccentricity is fixed at 2mm throughout the whole glenosphere range. the inferior offset reduces the risk of scapular notching, while the two options of lateralization allow the surgeon to select the desired level of rom and joint tension. device indicated for treatment of humeral fractures and for primary or revision total shoulder replacement in patients with a grossly rotator cuff deficient shoulder joint with severe arthropathy or a previously failed joint replacement. the patient?s joint must be anatomically and structurally suited to receive the selected implant(s), and a functional deltoid muscle is necessary to use the device. the glenoid baseplate is intended for cementless application with the addition of screws for fixation.

Medacta Shoulder System Humeral Diaphysis Cementless - Coated shoulder humeral stem prosthesis Ավստրալիա - անգլերեն - Department of Health (Therapeutic Goods Administration)

medacta shoulder system humeral diaphysis cementless - coated shoulder humeral stem prosthesis

medacta australia pty ltd - 39702 - coated shoulder humeral stem prosthesis - the device is manufactured from titianium. the shape of the humeral diaphysis devices was developed to be anatomical and provide a stable positioning in the canal, especially in the calcar region. fixation is achieved without the use of cement; stability is fostered by a titanium plasma spray and hydroxyapatite coating in the metaphyseal region. the devices can be used in anatomic and reverse configurations using either the anatomic metaphysis or the reverse metaphysis. device intended for use as a hemi or total shoulder replacement. it is a single-use device for the reconstruction of the gleno-humeral joint in case of osteoarthritis, rheumatoid arthritis, traumatic arthritis, avascular necrosis as well as complex fractures, post-traumatic malunion and revision of failed arthroplasty in patients with an intact or reparable rotator cuff shoulder joint.

Medacta Shoulder System Humeral Reverse HIghcross PE Liner - Reverse shoulder prosthesis cup Ավստրալիա - անգլերեն - Department of Health (Therapeutic Goods Administration)

medacta shoulder system humeral reverse highcross pe liner - reverse shoulder prosthesis cup

medacta australia pty ltd - 48092 - reverse shoulder prosthesis cup - the humeral reverse hc liner has a 5? wedged shape and can be coupled with the humeral reverse metaphysis in two orientations: depending on the joint?s stability of the single patient, the surgeon can intraoperatively decide between an inclination of 145?, which allows for a wider range of motion at the cost of a reduced stability in total adduction, or 155?, which is associated to a higher stability and reduced range of motion. device indicated for treatment of humeral fractures and for primary or revision total shoulder replacement in patients with a grossly rotator cuff deficient shoulder joint with severe arthropathy or a previously failed joint replacement. the patient?s joint must be anatomically and structurally suited to receive the selected implant(s), and a functional deltoid muscle is necessary to use the device. the glenoid baseplate is intended for cementless application with the addition of screws for fixation.

Medacta Shoulder System Humeral Reverse Metaphysis - Reverse shoulder prosthesis body Ավստրալիա - անգլերեն - Department of Health (Therapeutic Goods Administration)

medacta shoulder system humeral reverse metaphysis - reverse shoulder prosthesis body

medacta australia pty ltd - 60511 - reverse shoulder prosthesis body - the device is manufactured from titanium is used with the humeral diaphysis cementless implant. it is designed as an inset adapter to prevent excessive distalisation of the humerus and over-tensioning of the deltoid, and to reduce the lever arm during shoulder abduction. the device is fixed to the humeral diaphysis cementless implant with a locking screw. device indicated for treatment of humeral fractures and for primary or revision total shoulder replacement in patients with a grossly rotator cuff deficient shoulder joint with severe arthropathy or a previously failed joint replacement. the patient?s joint must be anatomically and structurally suited to receive the selected implant(s), and a functional deltoid muscle is necessary to use the device.

KALCIPOS-D FORTE 500mg/800 International Unit Film Coated Tablet Իռլանդիա - անգլերեն - HPRA (Health Products Regulatory Authority)

kalcipos-d forte 500mg/800 international unit film coated tablet

meda ab - calcium carbonate, colecalciferol - film coated tablet - 500mg/800 international unit - calcium, combinations with other drugs

KALCIPOS-D FORTE 500/800 mg/IU Tablets Chewable Իռլանդիա - անգլերեն - HPRA (Health Products Regulatory Authority)

kalcipos-d forte 500/800 mg/iu tablets chewable

meda ab - calcium, colecalciferol - tablets chewable - 500/800 mg/iu - calcium, combinations with other drugs

Kalcipos-D 500mg/800 IU chewable Tablets Մալթա - անգլերեն - Medicines Authority

kalcipos-d 500mg/800 iu chewable tablets

meda ab box 906, se-170 09 solna, sweden - calcium carbonate, colecalciferol - chewable tablet - calcium carbonate 500 mg colecalciferol 800 iu - mineral supplements

RELIFEX 500 Milligram Film Coated Tablet Իռլանդիա - անգլերեն - HPRA (Health Products Regulatory Authority)

relifex 500 milligram film coated tablet

meda ab - nabumetone - film coated tablet - 500 milligram - other antiinflammatory and antirheumatic agents, non-steroids