rondo audio processor - stimulator, electrical, auditory, cochlea
med-el implant systems australasia pty ltd - 35643 - stimulator, electrical, auditory, cochlea - an external component of the med-el cochlear implant (ci) system, includes the rondo audio processor and the audio processor accessories. in its basic configuration, the rondo audio processor consists of the control unit & battery pack. the finetuner facilitates access to various audio processor functions. the rondo is held in place by magnetic attraction over the implant. the rondo is an audio processor and an external part of the med-el cochlear implant system. the med-el cochlear implant system is intended to evoke auditory sensation via electrical stimulation of the auditory pathways for severely to profoundly hearing impaired individuals who obtain little or no benefit from acoustic amplification in the best aided condition. additionally, the med-el cochlear implant system used in combination with the flex24 electrode is intended to evoke auditory sensations via electrical stimulation or via combined electric-acoustic stimulation (eas) of the auditory pathways for partially deaf individuals, who obtain benefit from acoustic amplification in the lower frequencies only. the med-el cochlear implant system is also intended to evoke auditory sensations via electrical stimulation of the auditory pathways for individuals with single?sided deafness, which is defined as severe to profound hearing impairment in one ear and normal hearing or mild to moderate hearing impairment in the other ear.
boov-el gum scented hand sanitizer- benzalkonium chloride gel
townley, inc. - benzalkonium chloride (unii: f5um2km3w7) (benzalkonium - unii:7n6jud5x6y) - benzalkonium chloride 1 g in 59 g - use to decrease bacteria on the skin that could cause disease. home boov-el gum scented hand sanitizer 2 fl oz (59 ml)
boov-el gum scented hand sanitizer- benzalkonium chloride gel
foshan nanhai jinxiong toys c o., ltd - benzalkonium chloride (unii: f5um2km3w7) (benzalkonium - unii:7n6jud5x6y) - benzalkonium chloride 1 g in 59 g - use to decrease bacteria on the skin that could cause disease. home boov-el gum scented hand sanitizer 2 fl oz (59 ml)
stimulator, electrical, auditory, cochlea
med-el implant systems australasia pty ltd - 35643 - stimulator, electrical, auditory, cochlea - optional accessory tools used with med-el audio processors. the tools can assist with the troubleshooting of the audio processor or in the removal/unlocking of a securing mechanism of the audio processor.
rondo 2 audio processor - cochlear implant system sound processor
med-el implant systems australasia pty ltd - 47374 - cochlear implant system sound processor - the rondo 2 ap, an external component of the med-el ci system converts acoustic signals into electric signals. the hermetically sealed ap contains the electronics and rechargeable battery which powers the external and the implanted electronics. magnetic attraction holds the ap in place over the implant. the finetuner facilitates access to various ap functions. accessories assist with programming, alternate power source, troubleshooting & customisation. the rondo 2 is an audio processor and an external part of the med - el cochlear implant system. the med - el cochlear implant system is intended to evoke auditory sensation via electrical stimulation of the auditory pathways for severely to profoundly hearing impaired individuals who obtain little or no benefit from acoustic amplification in the best aided condition. additionally, the med - el cochlear implant system used in combination with the flex24 or flex20 electrode is intended to evoke auditory sensations via electrical stimulation or via combined electric-acoustic stimulation (eas) of the auditory pathways for partially deaf individuals, who obtain benefit from acoustic amplification in the lower frequencies only. the med - el cochlear implant system is also intended to evoke auditory sensations via electrical stimulation of the auditory pathways for individuals with single-sided deafness, which is defined as severe to profound hearing impairment in one ear and normal hearing or mild to moderate hearing impairment in the other ear. the auditory brainstem implant (abi) is used for electrical stimulation of the cochlear nucleus (cn) via an implanted stimulator and a specially designed electrode array to evoke auditory sensations in patients with non-functional cochlear nerves.
surgical procedure kit, ent, <specify>
med-el implant systems australasia pty ltd -
44066 - surgical procedure kit, ent,
surgical procedure kit, ent, <specify>
med-el implant systems australasia pty ltd -
44066 - surgical procedure kit, ent,
momentum el icd dr - d121 - defibrillator, implantable, automatic, dual-chamber
boston scientific pty ltd - 37265 - defibrillator, implantable, automatic, dual-chamber - momentum el dual chamber icd combines ventricular tachyarrhythmia therapy with ventricular and atrial pacing and sensing. cardioversion or defibrillation therapies include a range of low- and high- energy shocks using a biphasic waveform; and a choice of multiple shock vectors. this device is intended to provide ventricular antitachycardia pacing (atp) and ventricular defibrillation for automated treatment of life-threatening ventricular arrhythmias.
resonate el icd dr - d433 - defibrillator, implantable, automatic, dual-chamber
boston scientific pty ltd - 37265 - defibrillator, implantable, automatic, dual-chamber - resonate el dual chamber icd combines ventricular tachyarrhythmia therapy with ventricular and atrial pacing and sensing. cardioversion or defibrillation therapies include a range of low- and high- energy shocks using a biphasic waveform; and a choice of multiple shock vectors. this device is intended to provide ventricular antitachycardia pacing (atp) and ventricular defibrillation for automated treatment of life-threatening ventricular arrhythmias
momentum el icd vr - d120 - defibrillator, implantable, automatic
boston scientific pty ltd - 35852 - defibrillator, implantable, automatic - momentum el single-chamber icd combines ventricular tachyarrhythmia therapy with ventricular pacing and sensing. cardioversion or defibrillation therapies include a range of low- and high- energy shocks using a biphasic waveform; and a choice of multiple shock vectors. this device is intended to provide ventricular antitachycardia pacing (atp) and ventricular defibrillation for automated treatment of life-threatening ventricular arrhythmias.