Ország: Kanada
Nyelv: angol
Forrás: Health Canada
HYDROGEN PEROXIDE
VIROX TECHNOLOGIES INC
V07AV
TECHNICAL DISINFECTANTS
2%
LIQUID
HYDROGEN PEROXIDE 2%
DISINFECTANT (Medical Instruments)
4L
OTC
DISINFECTANTS (FOR AGENTS USED ON OBJECT)
Active ingredient group (AIG) number: 0106899018; AHFS:
CANCELLED POST MARKET
2008-09-10
INFECTION PREVENTION WITH CONFIDENCE! In the war against microbes, Accel® Disinfectants are the first _ACCEL _ _HLD5_ line of defense for Infection Prevention. Accel® provides comfort and confidence that commonly touched surfaces and instruments are rendered safe to use. Accel HLD5 is designed for use in instrument and device reprocessing of semi‐critical and critical devices where a high level disinfection and rapid contact time are required PREVention carries a 5 minute high level disinfection claim against bacteria, viruses, fungi , mycobacteria and spores. _5_ EFFICACY OF ACCEL HLD5 SPORICIDAL (6 HOURS AT 20°C): _Bacillus subtilis, Clostridium sporogenes_ TUBERCULOCIDAL (5 MIN AT 20°C): _Mycobacterium terrae_ FUNGICIDAL (5 MIN AT 20°C): _Trychophyton mentagrophytes_ BACTERICIDAL (5 MIN) AT 20°C : _Pseudomonas aeruginosa, Staphylococcus aureus, Salmonella choleraesuis_ VIRUCIDAL (5 MIN AT 20°C): Poliovirus, Sabin strain type 1, which allows for a General Virucide claim against most enveloped and non‐ enveloped viruses enveloped viruses. DIRECTIONS FOR USE _(HEAVILY SOILED SURFACES REQUIRE CLEANING PRIOR TO DISINFECTION)_ CRITICAL ITEMS: Chemosterilization for instruments and devices that come in contact with sterile tissue, the blood stream & recirculating body fluids – such as surgical instruments and foot care instruments. Place pre‐cleaned, rinsed and dried instruments into a container of undiluted Accel HLD5. Allow the instruments to soak for at least 6 hours. Remove and rinse with sterile water. (See Notice To User) SEMI‐CRITICAL ITEMS: High‐Level Disinfection for instruments and devices that come in contact with non‐intact skin or mucous membranes that are not normally considered sterile such as respiratory equipment, surgical mirrors etc. Place pre‐cleaned, rinsed and dried instruments into a container of undiluted Accel HLD5. Allow the instruments to soak for at least 5 minutes. Remove and rinse with sterile or potable water. (See Notice To User) 14 DAY RE‐USE CLAIM: This solut Olvassa el a teljes dokumentumot
MATERIAL SAFETY DATA SHEET 1. PRODUCT AND COMPANY IDENTIFICATION PRODUCT NAME Accel HLD5 MSDS NO. 001022 MANUFACTURER / Virox Technologies Inc., 2770 Coventry Rd., Oakville, ON, L6H 6R1, 905-813-0110 SUPPLIER EMERGENCY CONTACT Virox Technologies Inc., 1-800-387-7578 INFORMATION USE Chemosterilant and high level disinfectant 2. HAZARDS IDENTIFICATION EMERGENCY OVERVIEW Mildly irritaing to eyes. Avoid contact with eyes. POTENTIAL HEALTH EFFECTS ROUTE OF EXPOSURE Eye contact; skin contact; inhalation; ingestion. INHALATION None known. SKIN CONTACT May cause mild irritation. EYE CONTACT Mildly irritating to eyes. INGESTION May cause stomach distress if ingested in large quantities. 3. COMPOSITION/INFORMATION ON INGREDIENTS CHEMICAL NAME OTHER IDENTIFIERS Hydrogen peroxide 4. FIRST AID MEASURES FIRST AID PROCEDURES INHALATION Not a normal route of exposure. SKIN CONTACT Flush with cool water. Wash with soap and water. Obtain medical attention if irritation develops or persists. EYE CONTACT Immediately flush the contaminated eye(s) with cool, gently flowing water for 15-20 minutes, while holding the eyelid(s) open. Remove contact lenses, if applicable, and continue washing. If irritation or pain persists, see a doctor. INGESTION Have victim rinse mouth with water. Have victim drink one or two glasses of water if able to. NEVER give anything by mouth if victim is rapidly losing consciousness, or is unconscious or convulsing. DO NOT INDUCE VOMITING. 5. FIRE FIGHTING MEASURES FLAMMABLE PROPERTIES Not flammable by WHMIS/OSHA criteria. SUITABLE EXTINGUISHING Not combustible. Use extinguishing agent suitable for surrounding fire. MEDIA SPECIFIC HAZARDS Decomposition releases oxygen which may intensify fire. ARISING FROM THE CHEMICAL PROTECTIVE EQUIPMENT As in any fire, wear self-contained breathing apparatus pressure-demand, MSHA/NIOSH AND PRECAUTIONS FOR (approved or equivalent) and full protective gear. FIREFIGHTERS MSDS Name: Accel HLD5 MSDS No.: 001022 Page 01 of 04 Date of Preparation: May 30, 2014 ACCEL HLD5 CAS NO. 77 Olvassa el a teljes dokumentumot