NexGen? Complete Knee Solution, Trabecular Metal? Augmentation Patella - Metal-backed patella prosthesis Australie - anglais - Department of Health (Therapeutic Goods Administration)

nexgen? complete knee solution, trabecular metal? augmentation patella - metal-backed patella prosthesis

zimmer biomet pty ltd - 34192 - metal-backed patella prosthesis - the nexgen augmentation patella consists of a polyethylene patella and an augmentation base made from trabecular metal with a titanium alloy suture ring for additional fixation to the patellar tendon and remaining bone stock. both these components have an oval geometry and are indicated for cemented and cementless use. the nexgen augmentation patella is indicated for use in procedures involving: - revision total knee arthroplasty with inadequate patellar bone stock for standard patellar revision - patellar fracture after total knee arthroplasty.

NexGen? Complete Knee Solution, Stemmed Tibial Component, Precoat - Coated knee tibia prosthesis Australie - anglais - Department of Health (Therapeutic Goods Administration)

nexgen? complete knee solution, stemmed tibial component, precoat - coated knee tibia prosthesis

zimmer biomet pty ltd - 34198 - coated knee tibia prosthesis - the device is a stemmed tibial component of the nexgen? semiconstrained, nonlinked condylar knee system. the nexgen stem base is designed to resist base plate lift-off due to tilting that can result from poor bone stock. it is manufactured from tivanium? ti?6al?4v alloy with a pmma precoat. for use with or without a stem extension. in the absence of a stem extension, the distal stem taper is capped with a preassembled modular uhmwpe plug. indicated for cemented use only. the nexgen stemmed tibial component, precoat is a semiconstrained, nonlinked condylar knee prosthesis indicated for patients with severe knee pain and disability due to rheumatoid arthritis, osteoarthritis, traumatic arthritis, polyarthritis; collagen disorders, and/or avascular necrosis of the femoral condyle; post-traumatic loss of joint configuration, particularly when there is patellofemoral erosion, dysfunction or prior patellectomy; moderate valgus, varus, or flexion deformities; the salvage of previously failed surgical attempts or for a knee in which satisfactory stability in flexion cannot be obtained at the time of surgery.

NexGen? Complete Knee Solution, Fluted Stem Mobile Tibial Component, Precoat Stemmable - Uncoated knee tibia prosthesis, metalli Australie - anglais - Department of Health (Therapeutic Goods Administration)

nexgen? complete knee solution, fluted stem mobile tibial component, precoat stemmable - uncoated knee tibia prosthesis, metalli

zimmer biomet pty ltd - 32832 - uncoated knee tibia prosthesis, metallic - fluted stem mobile tibial baseplate component of the nexgen lps mobile semiconstrained, nonlinked condylar mobile bearing knee prostheses system designed to allow ?25 degrees of rotational movement. it is manufactured from zimaloy? cobalt-chromium-molybdenum alloy, and consists of a tivanium substrate with pmma precoating on the bone interface surfaces. intended for cemented use only. the fluted stem mobile tibial baseplate a component of the nexgen cr-flex mobile bearing knee system is indicated for patients with severe knee pain and disability due to: rheumatoid arthritis, osteoarthritis, traumatic arthritis, polyarthritis. collagen disorders, and/or avascular necrosis of the femoral condyle, post-traumatic loss of joint configuration, particularly when there is patellofemoral erosion, dysfunction or prior patellectomy. moderate valgus, varus, or flexion deformities. the salvage of previously failed surgical attempts or for a knee in which satisfactory stability in flexion cannot be obtained at the time of

NexGen? Complete Knee Solution Prolong Highly Crosslinked Polyethylene UC-Flex Mobile Bearing Articular Surface - Prosthesis, kn Australie - anglais - Department of Health (Therapeutic Goods Administration)

nexgen? complete knee solution prolong highly crosslinked polyethylene uc-flex mobile bearing articular surface - prosthesis, kn

zimmer biomet pty ltd - 46585 - prosthesis, knee, internal, insert component - ultracongruent mobile bearing articular surface component of the nexgen? cr mobile semiconstrained, nonlinked condylar mobile bearing knee prostheses system. it is manufactured from ultra-high molecular weight polyethylene and intended for use with an absent or deficient posterior cruciate ligament to increase anterior constraint. the device is compatible with femoral components from the nexgen cr, cra and cr-flex systems. the articular surface component of the nexgen cr-flex mobile bearing knee system is indicated for use in patients with severe knee pain and disability due to: rheumatoid arthritis, osteoarthritis, traumatic arthritis, polyarthritis. collagen disorders, and/or avascular necrosis of the femoral condyle, post-traumatic loss of joint configuration, particularly when there is patellofemoral erosion, dysfunction or prior patellectomy. moderate valgus, varus, or flexion deformities. the salvage of previously failed surgical attempts or for a knee in which satisfactory stability in flexion cannot

NexGen? Complete Knee Solution Prolong? (HXLPE) CR-Flex Mobile Bearing Articular Surface, Regular Constraint - Prosthesis, knee, internal, insert component Australie - anglais - Department of Health (Therapeutic Goods Administration)

nexgen? complete knee solution prolong? (hxlpe) cr-flex mobile bearing articular surface, regular constraint - prosthesis, knee, internal, insert component

zimmer biomet pty ltd - 46585 - prosthesis, knee, internal, insert component - articular surface component of the nexgen? cr mobile semiconstrained, nonlinked condylar mobile bearing knee prostheses system.? they are available in multiple thicknesses to facilitate soft tissue tensioning and joint line restoration and intended for use with a functional posterior cruciate ligament (pcl). manufactured from prolong highly crosslinked polyethylene. the device is compatible with femoral components from the nexgen cr, cra and cr-flex systems. the articular surface component of the nexgen cr-flex mobile bearing knee system is indicated for patients with severe knee pain and disability due to: rheumatoid arthritis, osteoarthritis, traumatic arthritis, polyarthritis. collagen disorders, and/or avascular necrosis of the femoral condyle, post-traumatic loss of joint configuration, particularly when there is patellofemoral erosion, dysfunction or prior patellectomy. moderate valgus, varus, or flexion deformities. the salvage of previously failed surgical attempts or for a knee in which satisfactory stability in flexion cannot be obtained at the time of surgery.

NexGen? CKS PROLONG? LPS-Mobile Articular Surface with Locking Screw - Prosthesis, knee, internal, insert component Australie - anglais - Department of Health (Therapeutic Goods Administration)

nexgen? cks prolong? lps-mobile articular surface with locking screw - prosthesis, knee, internal, insert component

zimmer biomet pty ltd - 46585 - prosthesis, knee, internal, insert component - posterior ligament stabilising articular surface component of the nexgen lps mobile semiconstrained, nonlinked condylar mobile bearing knee prostheses system. it rotates on a highly polished trunnion on the fluted stem tibial baseplate and is available in multiple thicknesses to facilitate soft tissue tensioning and joint line restoration. manufactured from prolong™ ultra high molecular-weight polyethylene(uhmwpe). the locking screw is made of zimaloy cobalt-chromium-molybdenum alloy. the articular surface, a component of the nexgen lps mobile bearing knee, is indicated for patients with severe knee pain and disability due to: rheumatoid arthritis, osteoarthritis, traumatic arthritis, polyarthritis. collagen disorders, and/or avascular necrosis of the femoral condyle. post-traumatic loss of joint configuration, particularly when there is patellofemoral erosion, dysfunction or prior patellectomy. moderate valgus, varus, or flexion deformities. the salvage of previously failed surgical attempts or for a knee in which satisfactory stability in flexion cannot be obtained at the time of surgery.

NexGen? Complete Knee Solution Legacy? Knee Posterior Stablized PROLONG? Highly XLP LPS-Mobile Articular Surface - Prosthesis, inter - Prosthesis, knee, internal, insert component Australie - anglais - Department of Health (Therapeutic Goods Administration)

nexgen? complete knee solution legacy? knee posterior stablized prolong? highly xlp lps-mobile articular surface - prosthesis, inter - prosthesis, knee, internal, insert component

zimmer biomet pty ltd - 46585 - prosthesis, knee, internal, insert component - posterior ligament stabilising articular surface component of the nexgen lps mobile semiconstrained, nonlinked condylar mobile bearing knee prostheses system. it rotates on a highly polished trunnion on the fluted stem tibial baseplate and is available in multiple thicknesses to facilitate soft tissue tensioning and joint line restoration. manufactured from prolong? ultra high molecular-weight polyethylene(uhmwpe). posterior ligament stabilising articular surface component of the nexgen lps mobile semiconstrained, nonlinked condylar mobile bearing knee prostheses system used to articulate the femoral and the tibial components of a knee joint prosthesis, for patients with severe knee pain and disability due to: rheumatoid arthritis, osteoarthritis, traumatic arthritis, polyarthritis. collagen disorders, and/or avascular necrosis of the femoral condyle. post-traumatic loss of joint configuration, particularly when there is patellofemoral erosion, dysfunction or prior patellectomy. moderate valgus, varus, or flexion deformities. the salvage of previously failed surgical attempts or for a knee in which satisfactory stability in flexion cannot be obtained at the time of surgery.

NexGen? CKS Legacy? Knee LPS-Mobile Articular Surface with Locking Screw - Prosthesis, inter - Prosthesis, knee, internal, insert component Australie - anglais - Department of Health (Therapeutic Goods Administration)

nexgen? cks legacy? knee lps-mobile articular surface with locking screw - prosthesis, inter - prosthesis, knee, internal, insert component

zimmer biomet pty ltd - 46585 - prosthesis, knee, internal, insert component - posterior stabilised mobile articular surface component of the nexgen lps mobile semiconstrained, nonlinked condylar mobile bearing knee prostheses system. it rotates on a highly polished trunnion on the fluted stem tibial baseplate and is manufactured from ultra-high molecular weight polyethylene (uhmwpe). it is available in multiple thicknesses to facilitate soft tissue tensioning and joint line restoration and contains locking screw made from cocomo alloy. posterior stabilised mobile articular surface with locking screw component of the nexgen lps mobile semiconstrained, nonlinked condylar mobile bearing knee prostheses system indicated for use in patients with severe knee pain and disability due to: rheumatoid arthritis, osteoarthritis, traumatic arthritis, polyarthritis. collagen disorders, and/or avascular necrosis of the femoral condyle. post-traumatic loss of joint configuration, particularly when there is patellofemoral erosion, dysfunction or prior patellectomy. moderate valgus, varus, or flexion deformities. the salvage of previously failed surgical attempts or for a knee in which satisfactory stability in flexion cannot be obtained at the time of surgery.

NexGen? Complete Knee Solution, Cruciate Retaining (CR) Stemmed Tibial Component - All Poly Cemented - Prosthesis, knee, internal, insert component Australie - anglais - Department of Health (Therapeutic Goods Administration)

nexgen? complete knee solution, cruciate retaining (cr) stemmed tibial component - all poly cemented - prosthesis, knee, internal, insert component

zimmer biomet pty ltd - 46585 - prosthesis, knee, internal, insert component - cruciate ligament retaining(cr) stemmed tibial component of the nexgen semiconstrained, nonlinked condylar knee system. it is made from ultra-high molecular weight polyethylene and indicated for cemented use only. cruciate ligament retaining(cr) stemmed tibial component of the nexgen semiconstrained, nonlinked condylar knee prosthesis system indicated for patients with severe knee pain and disability due to: ? rheumatoid arthritis, osteoarthritis, traumatic arthritis, polyarthritis. ? collagen disorders, and/or avascular necrosis of the femoral condyle. ? post-traumatic loss of joint configuration, particularly when there is patellofemoral erosion, dysfunction or prior patellectomy. ? moderate valgus, varus, or flexion deformities. ? the salvage of previously failed surgical attempts or for a knee in which satisfactory stability in flexion cannot be obtained at the at the time of surgery.

NexGen? Complete Knee Solution Legacy?-Knee LPS-Mobile Articular Surface - Prosthesis, inter - Prosthesis, knee, internal, insert component Australie - anglais - Department of Health (Therapeutic Goods Administration)

nexgen? complete knee solution legacy?-knee lps-mobile articular surface - prosthesis, inter - prosthesis, knee, internal, insert component

zimmer biomet pty ltd - 46585 - prosthesis, knee, internal, insert component - posterior stabilised mobile articular surface component of the nexgen lps mobile semiconstrained, nonlinked condylar mobile bearing knee prostheses system. it rotates on a highly polished trunnion on the fluted stem tibial baseplate and is manufactured from ultra-high molecular weight polyethylene (uhmwpe). it is available in multiple thicknesses to facilitate soft tissue tensioning and joint line restoration. posterior stabilised mobile articular surface component of the nexgen lps mobile semiconstrained, nonlinked condylar mobile bearing knee prostheses system indicated for use in patients with severe knee pain and disability due to: rheumatoid arthritis, osteoarthritis, traumatic arthritis, polyarthritis. collagen disorders, and/or avascular necrosis of the femoral condyle. post-traumatic loss of joint configuration, particularly when there is patellofemoral erosion, dysfunction or prior patellectomy. moderate valgus, varus, or flexion deformities. the salvage of previously failed surgical attempts or for a knee in which satisfactory stability in flexion cannot be obtained at the time of surgery.