Clinician Programmer Model NM-7153-11A - Multi-purpose electrical stimulation system programmer Australie - anglais - Department of Health (Therapeutic Goods Administration)

clinician programmer model nm-7153-11a - multi-purpose electrical stimulation system programmer

boston scientific pty ltd - 61393 - multi-purpose electrical stimulation system programmer - clinician programmer allows the set-up and adjustment of stimulation parameters for the precision spectra spinal cord stimulator system via a programming wand. the programming wand uses radio frequency link to communicate with the stimulator. the clinician programmer is packaged with the programming wand and a usb cable the clinician programmer is intended to allow setting and adjustment of stimulation parameters for your spinal cord stimulation system.

Clinician Programmer NM-7153-30 - Computer, laptop Australie - anglais - Department of Health (Therapeutic Goods Administration)

clinician programmer nm-7153-30 - computer, laptop

boston scientific pty ltd - 38453 - computer, laptop - clinician programmer allows the set-up and adjustment of stimulation parameters for the precision & precision spectra spinal cord stimulator system via a programming wand. the programming wand uses radio frequency link to communicate with the stimulator. the clinician programmer (cp) uses software that allows the set-up and adjustment of stimulation parameters for the stimulator (implantable pulse generator or external trial stimulator).

Dental cement, composite, temporary Australie - anglais - Department of Health (Therapeutic Goods Administration)

dental cement, composite, temporary

sdi ltd - 46939 - dental cement, composite, temporary - temporary dental cement

Clinician Programmer with Bionic Navigator Software (SC-7150-4) - Computer interface Australie - anglais - Department of Health (Therapeutic Goods Administration)

clinician programmer with bionic navigator software (sc-7150-4) - computer interface

boston scientific pty ltd - 16902 - computer interface - the clinician programmer with bionic navigator software communicates with the stimulator using an infrared link to the remote control. programs can be loaded to the programmer for previewing, activating and changing stimulation patterns. it is also used to identify both pain and paresthesia areas using a visual representation of anatomical coverage areas in relation to the patient the clinician programmer with bionic navigator software is used to program an implantable pulse generator which is indicated as an aid in the management of chronic intractable pain of the trunk and/or limbs, including unilateral or bilateral pain associated with the following: failed back surgery syndrome, intractable low back pain and leg pain.

Clinician programmer - Multi-purpose electrical stimulation system programmer Australie - anglais - Department of Health (Therapeutic Goods Administration)

clinician programmer - multi-purpose electrical stimulation system programmer

boston scientific pty ltd - 61393 - multi-purpose electrical stimulation system programmer - the clinician programmer (cp) is a commercial off-the-shelf computer customised by programming software. the device communicates with the stimulator via a programming wand. the programming wand uses a radio frequency (rf) link to communicate with the stimulator. programs can be created and downloaded to the cp for previewing, activating, and changing stimulation parameters. stimulation programs can also be saved to the stimulator. the clinician programmer (cp) is a computer installed with programming software. it is used to set and adjust stimulation parameters of stimulators by communicating wirelessly via a radio frequency link.

Precision Spectra Clinician Programmer NM-7151-30 - Computer, laptop Australie - anglais - Department of Health (Therapeutic Goods Administration)

precision spectra clinician programmer nm-7151-30 - computer, laptop

boston scientific pty ltd - 38453 - computer, laptop - clinician programmer allows the set-up and adjustment of stimulation parameters for the precision spectra spinal cord stimulator system via a programming wand. the programming wand uses radio frequency link to communicate with the stimulator. the precision spectra clinician programmer is part of the precision spectra system that is intended to aid in the management of chronic intractable pain.

Clinician Programmer App, Model 3874 - Multi-purpose electrical stimulation system programmer Australie - anglais - Department of Health (Therapeutic Goods Administration)

clinician programmer app, model 3874 - multi-purpose electrical stimulation system programmer

abbott medical australia pty ltd - 61393 - multi-purpose electrical stimulation system programmer - the clinician programmer app is installed onto a compatible apple device and interfaces wirelessly with compatible neurostimulation systems to non-invasively program and control device parameters. the device is intended to help clinicians program stimulation parameters for st. jude medical? neurostimulation systems and create customized therapy for patients.

Clinician Programmer ? PSM1001 - Multi-purpose electrical stimulation system programmer Australie - anglais - Department of Health (Therapeutic Goods Administration)

clinician programmer ? psm1001 - multi-purpose electrical stimulation system programmer

lmt surgical pty ltd - 61393 - multi-purpose electrical stimulation system programmer - the clinician programmer consists of a tablet pc and a programming wand. pins programming and control firmware is installed in the tablet pc. the tablet pc sends commands or receives data to/from the programming wand via bluetooth, and the wand then sends/receives the information to/from the ipg via the inductive telemetry. the clinician programmer model is one of the external devices of the pinstm deep brain stimulation system. it enables physicians to remotely program and control the pulse generator.

Clinician Programmer Application A610 - Multi-purpose electrical stimulation system programmer Australie - anglais - Department of Health (Therapeutic Goods Administration)

clinician programmer application a610 - multi-purpose electrical stimulation system programmer

medtronic australasia pty ltd - 61393 - multi-purpose electrical stimulation system programmer - the model a610 clinician programmer application (cpa) for deep brain stimulation is a stand-alone software application installed on a tablet, an off-the-shelf mobile platform that is a non-medical device the medtronic clinician programmer software a610 is intended for use by clinicians in the programming of neurostimulators (external and implantable) for deep brain stimulation (dbs).

Clinician App for Sacral Neuromodulation Therapy A510 - Multi-purpose electrical stimulation system programmer Australie - anglais - Department of Health (Therapeutic Goods Administration)

clinician app for sacral neuromodulation therapy a510 - multi-purpose electrical stimulation system programmer

medtronic australasia pty ltd - 61393 - multi-purpose electrical stimulation system programmer - the medtronic model a510 clinician application is preloaded on a non-medical cots handset (e.g. samsung smartphone). it is used together with the model tm90 communicator by the clinician to program stimulation settings for the medtronic interstim neurostimulators for snm therapy. the medtronic model a510 clinician application (app)is intended for use with the hh90 handset and tm90 communicator to program, adjust, and troubleshoot the medtronic models 3023 and 3058 interstim? neurostimulators for sacral neuromodulation therapy. the clinician uses the clinician app to program settings for the patient.