Bio-Rad PLATELIA™ RUBELLA IgG Singapore - englanti - HSA (Health Sciences Authority)

bio-rad platelia™ rubella igg

bio-rad laboratories (singapore) pte ltd - microbiology - the platelia rubella igg assay is an indirect enzyme immunoassay kit for the quantitative determination of igg antibodies to rubella in human serum or plasma specimens. this kit can be used as an aid in the diagnosis of rubella infection for any individual susceptible to be infected including pregnant women as well as in the determination of immune status to rubella. the platelia rubella igg assay can be used manually or on automated systems.

Bio-Rad Viroclear serology control Singapore - englanti - HSA (Health Sciences Authority)

bio-rad viroclear serology control

bio-rad laboratories (singapore) pte ltd - microbiology - viroclear is intended for use as an unassayed non-reactive quality assurance reagent with in vitro assays detecting antibody to human immunodeficiency virus type 1 (anti-hiv-1), antibody to human immunodeficiency virus type 2 (anti-hiv-2), antibody to human t-lymphotropic virus type i (anti-htlv-i), human immunodeficiency virus type 1 antigen (hiv-1 ag), antibody to human t-lymphotropic virus type ii (anti-htlv-ii), antibody to hepatitis c virus (anti-hcv), immunoglobulin m and total antibodies to hepatitis b core antigen (anti-hbc igm and anti-hbc total), hepatitis b surface antigen (hbsag), antibody to hepatitis b surface antigen (anti-hbs), immunoglobulin m and total antibody to hepatitis a virus (anti-hav igm and anti-hav total), hepatitis b e antigen (hbeag), antibody to hepatitis b e antigen (anti-hbe), antibody to cytomegalovirus (anti-cmv), immunoglobulin g (igg) and immunoglobulin m (igm), antibodies to treponema pallidum and non-treponemal antibodies (reagin).

Bio-Rad VIROTROL HIV-1gO Singapore - englanti - HSA (Health Sciences Authority)

bio-rad virotrol hiv-1go

bio-rad laboratories (singapore) pte ltd - microbiology - virotrol hiv-1 go is intended for use as an unassayed reactive quality control with in vitro assay procedures for determination of antibodies to human immunodeficiency virus type 1 (hiv-1 group o) in human serum or plasma. this product is intended to provide a means of estimating precision and has the potential for detecting systematic deviations from specific laboratory testing procedures. specific reactivity for other hiv-1 subtypes (m or n), and hiv-2 has not been established. this product is not intended for use with blood screening assays.

Bio-Rad Virotrol III serology control Singapore - englanti - HSA (Health Sciences Authority)

bio-rad virotrol iii serology control

bio-rad laboratories (singapore) pte ltd - microbiology - virotrol iii intended for use as an unassayed reactive control with in vitro assay procedures for the qualitative determination of immunoglobulin m antibodies to hepatitis a virus (hav-igm), immunoglobulin m antibodies to hepatitis b core antigen (hbc-igm), and total antibody to hepatitis a virus (anti-hav). specific reactivity for immunoglobulin g antibodies to hepatitis a virus has not been established. this product is intended to provide a means of estimating precision and has the potential for detecting systematic deviations from specific laboratory testing procedures.

Bio-Rad Virotrol Plus-R Singapore - englanti - HSA (Health Sciences Authority)

bio-rad virotrol plus-r

bio-rad laboratories (singapore) pte ltd - microbiology - virotrol plus-r is intended for use as an unassayed reactive quality control with in vitro assay procedures for determination of antibodies to human immunodeficiency virus type 1/2 (hiv-1/2), antibodies to human t-lymphotropic virus type i/ii (htlv-i/ii), antibodies to hepatitis c virus (hcv), hepatitis b surface antigen (hbsag), antibodies to hepatitis b core antigen (hbc), antibodies to cytomegalovirus (cmv) and total antibodies to treponema pallidum. this product is intended to provide a means of estimating precision and has the potential for detecting systematic deviations from specific laboratory testing procedures.

Bio-rad Virotrol HIV-1 Ag Control Singapore - englanti - HSA (Health Sciences Authority)

bio-rad virotrol hiv-1 ag control

bio-rad laboratories (singapore) pte ltd - microbiology - intended for use as an unassayed reactive quality control with in vitro assay procedures for determination of antigens to human immunodeficiency virus type 1 (hiv-1). this product is intended to provide a means of estimating precision and has the potential for detecting systematic deviations from specific laboratory testing procedures.

Bio-rad Virotrol HIV-2 Control Singapore - englanti - HSA (Health Sciences Authority)

bio-rad virotrol hiv-2 control

bio-rad laboratories (singapore) pte ltd - microbiology - intended for use as an unassayed reactive control with in vitro assay procedures for determination of antibodies to human immunodeficiency virus type 2 (hiv-2). this product is intended to provide a means of estimating precision and has the potential for detecting systematic deviations from specific laboratory testing procedures.

Bio-Rad VIROTROL I serology control Singapore - englanti - HSA (Health Sciences Authority)

bio-rad virotrol i serology control

bio-rad laboratories (singapore) pte ltd - microbiology - virotrol i is intended for use with in vitro assay procedures for determination of antibodies to human immunodeficiency virus type 1 (hiv-1), antibodies to human t-lymphotropic virus type i (htlv-i), antibodies to hepatitis c virus (hcv), hepatitis b surface antigen (hbsag), antibodies to hepatitis b core antigen (hbc) and antibodies to cytomegalovirus (cmv). this product is intended to provide a means of estimating precision and has the potential for detecting systematic deviations from specific laboratory testing procedures.

Bio-Rad Virotrol II serology control Singapore - englanti - HSA (Health Sciences Authority)

bio-rad virotrol ii serology control

bio-rad laboratories (singapore) pte ltd - microbiology - virotrol ii is an unassayed positive control prepared from processed human plasma or serum and is intended for use with in vitro assay procedures for determination of antibodies to hepatitis b surface antigen (anti-hbs) and qualitative assay procedures for determination of antibodies to hepatitis a virus (anti-hav). this product is intended to provide a means of estimating precision and has the potential for detecting systematic deviations from specific laboratory testing procedures.

Bio-Rad GENSCREEN HIV 12 version 2 Singapore - englanti - HSA (Health Sciences Authority)

bio-rad genscreen hiv 12 version 2

bio-rad laboratories (singapore) pte ltd - immunology - bio-rad genscreen® hiv 1/2 version 2 is an immunoassay based on the principle of a two-step sandwich technique for the detection of the various antibodies associated with hiv1 and/or hiv2 virus in human serum or plasma.