VISIONIST X4 CRT-P U228 - Biventricular pacemaker Australia - inglés - Department of Health (Therapeutic Goods Administration)

visionist x4 crt-p u228 - biventricular pacemaker

boston scientific pty ltd - 47263 - biventricular pacemaker - this pulse generator provides a variety of therapies, including cardiac resynchronization therapy (crt), which treats heart failure by resynchronizing ventricular contractions through biventricular electrical stimulation and bradycardia pacing, including adaptive rate pacing, to detect and treat bradyarrhythmias. device includes zip telemetry. connector type ra: is-1, rv: is-1, lv: is4. case is hermetically sealed titanium. supplied with a torque wrench. boston scientific cardiac resynchronization therapy pacemakers (crt-ps) are indicated for patients who have symptomatic congestive heart failure including left ventricular dysfunction and wide qrs; and/or one or more of the following conditions: ? symptomatic paroxysmal or permanent second- or third-degree av block ? symptomatic bilateral bundle branch block ? symptomatic paroxysmal or transient sinus node dysfunction with or without associated av conduction disorders (i.e., sinus bradycardia, sinus arrest, sinoatrial [sa] block) ? bradycardia-tachycardia syn

VISIONIST CRT-P U226 - Biventricular pacemaker Australia - inglés - Department of Health (Therapeutic Goods Administration)

visionist crt-p u226 - biventricular pacemaker

boston scientific pty ltd - 47263 - biventricular pacemaker - this pulse generator provides a variety of therapies, including cardiac resynchronization therapy (crt), which treats heart failure by resynchronizing ventricular contractions through biventricular electrical stimulation and bradycardia pacing, including adaptive rate pacing, to detect and treat bradyarrhythmias. device includes zip telemetry. connector type ra: is-1, rv: is-1, lv: lv-1. case is hermetically sealed titanium. supplied with a torque wrench. boston scientific cardiac resynchronization therapy pacemakers (crt-ps) are indicated for patients who have symptomatic congestive heart failure including left ventricular dysfunction and wide qrs; and/or one or more of the following conditions: ? symptomatic paroxysmal or permanent second- or third-degree av block ? symptomatic bilateral bundle branch block ? symptomatic paroxysmal or transient sinus node dysfunction with or without associated av conduction disorders (i.e., sinus bradycardia, sinus arrest, sinoatrial [sa] block) ? bradycardia-tachycardia sy

VISIONIST CRT-P U225 - Biventricular pacemaker Australia - inglés - Department of Health (Therapeutic Goods Administration)

visionist crt-p u225 - biventricular pacemaker

boston scientific pty ltd - 47263 - biventricular pacemaker - this pulse generator provides a variety of therapies, including cardiac resynchronization therapy (crt), which treats heart failure by resynchronizing ventricular contractions through biventricular electrical stimulation and bradycardia pacing, including adaptive rate pacing, to detect and treat bradyarrhythmias. device includes zip telemetry. connector type ra: is-1, rv: is-1, lv: is-1. case is hermetically sealed titanium. supplied with a torque wrench. boston scientic cardiac resynchronization therapy pacemakers (crt-ps) are indicated for patients who have symptomatic congestive heart failure including left ventricular dysfunction and wide qrs; and/or one or more of the following conditions: ? symptomatic paroxysmal or permanent second- or third-degree av block ? symptomatic bilateral bundle branch block ? symptomatic paroxysmal or transient sinus node dysfunction with or without associated av conduction disorders (i.e., sinus bradycardia, sinus arrest, sinoatrial [sa] block) ? bradycardia-tachycardia synd

ARES? Catheter Kit - Catheter, neurological, ventricular Australia - inglés - Department of Health (Therapeutic Goods Administration)

ares? catheter kit - catheter, neurological, ventricular

medtronic australasia pty ltd - 32585 - catheter, neurological, ventricular - each ares catheter kit includes an ares ventricular catheter with an integral right angle clip, stainless steel stylet and an ares peritoneal catheter. intended for use in the treatment of hydrocephalus as a component of a shunt system when draining or shunting of cerebrospinal fluid (csf) is indicated.

Quadra Allure MP RF PM3262 - Biventricular pacemaker Australia - inglés - Department of Health (Therapeutic Goods Administration)

quadra allure mp rf pm3262 - biventricular pacemaker

abbott medical australia pty ltd - 47263 - biventricular pacemaker - the quadra allure mp rf pm3262 is a crt-p with rf telemetry which monitors and regulates the patient's heart rate through dual chamber bradycardia pacing and improve ventricular resynchronization through biventricular pacing. it is a quadripolar device with multipoint pacing and provides the option to select from 4 left ventricular pacing electrodes and 14 pacing vectors. the quadra allure mp rf pm3262 is intended to be implanted when a patient has one or more of the following permanent conditions: syncope, presyncope, fatigue, disorientation due to arrhythmia/bradycardia, or any combination of these symptoms. the implantation of quadra allure mp rf pm3262 is also intended for patients who would benefit from resynchronisation of the right and left ventricles or have one or more conventional indications for the implantation of a pacemaker. also the quadra allure mp rf pm3262 is indicated for patients who exhibit sick sinus syndrome, chronic symptomatic second-degree and third-degree av block, recurrent adam-stokes syndrome and symptomatic bilateral bundle branch block when tachyarrhythmia and other causes have been ruled out.

HeartMate II Sealed Inflow Conduit - Implantable ventricular circulatory assist system inflow cannula, animal-derived Australia - inglés - Department of Health (Therapeutic Goods Administration)

heartmate ii sealed inflow conduit - implantable ventricular circulatory assist system inflow cannula, animal-derived

abbott medical australia pty ltd - 61749 - implantable ventricular circulatory assist system inflow cannula, animal-derived - the sealed inflow conduit of the pump is attached to the apex of the left ventricle and the pump sealed outflow graft is connected to the ascending aorta. the sealed inflow conduit and outflow elbows have a textured titanium microsphere surface. intended as a component of a ventricular circulatory assist system for haemodynamic support to patients with end stage refactory left ventricular heart failure.

HeartMate II Sealed Outflow Graft with Bend Relief - Implantable ventricular circulatory assist system outflow cannula, animal-d Australia - inglés - Department of Health (Therapeutic Goods Administration)

heartmate ii sealed outflow graft with bend relief - implantable ventricular circulatory assist system outflow cannula, animal-d

abbott medical australia pty ltd - 61747 - implantable ventricular circulatory assist system outflow cannula, animal-derived - the sealed inflow conduit of the pump is attached to the apex of the left ventricle and the pump sealed outflow graft is connected to the ascending aorta. the sealed inflow conduit and outflow elbows have a textured titanium microsphere surface. intended as a component of a ventricular circulatory assist system for haemodynamic support to patients with end stage refactory left ventricular heart failure.