Beckman Coulter SYNCHRON CX Systems ISE Electrolyte ReferenceBuffer Reagents Singapore - English - HSA (Health Sciences Authority)

beckman coulter synchron cx systems ise electrolyte referencebuffer reagents

beckman coulter singapore pte. ltd. - clinical chemistry - synchron cx ise electrolyte buffer reagent and the ise electrolyte reference reagent, in conjunction with synchron cx® systems and synchron® systems calibrators 1, 2 and 3, are intended for the quantitative determination of sodium, potassium, chloride, calcium and carbon dioxide concentration in human serum, plasma, csf, or urine.

OVURELIN INJECTION Australia - English - APVMA (Australian Pesticides and Veterinary Medicines Authority)

ovurelin injection

elanco australasia pty ltd - gonadorelin as gonadorelin acetate - parenteral liquid/solution/suspension - gonadorelin as gonadorelin acetate hormone-gonadotrophin active 100.0 ug/ml - endocrine system - cattle | beef | bos indicus | bos taurus | bovine | buffalo | bull | bullock | calf | cow | dairy cow | heifer | steer - cystic ovaries | delayed ovulation | improvement of postpartum fertility | synchronisation of oestrus & ovulation | post-partum fertility

Synchro 2 Guidewire - Catheter guide wire Australia - English - Department of Health (Therapeutic Goods Administration)

synchro 2 guidewire - catheter guide wire

stryker australia pty ltd - 35094 - catheter guide wire - synchro 2 is a steerable guidewire with a shapeable tip and is available in straight or pre-shaped versions. the distal portion of the guidewire tip is radiopaque. the distal portion of the device is coated with a hydrophilic polymer and the proximal portion is coated with ptfe. the synchro 2 guidewire is intended for general intravascular use, including neurovasculature and peripheral vasculature. it can also be used to selectively introduce and position catheters and other interventional devices within the peripheral and neurovasculature.

Synchro Guidewire - Catheter guide wire Australia - English - Department of Health (Therapeutic Goods Administration)

synchro guidewire - catheter guide wire

stryker australia pty ltd - 35094 - catheter guide wire - synchro is a steerable guidewire with a shapeable distal tip. the guidewires are compatible with existing microcatheters used in common procedures such as those used in endovascular diagnosis and therapy neurovascular disease. the proximal portion is coated with polytetrafluoroethylene (pfte) and the distal portion of the guidewire is radiopaque and coated with hydrophilic polymers. it also includes a torque device and an introducer. the guidewire is intended to be used for neurovasculature use. it can also be used to selectively introduce and position catheters and other interventional devices within the neurovasculature.

MED-EL SYNCHRONY 2 Mi1250 Cochlear Implant System Singapore - English - HSA (Health Sciences Authority)

med-el synchrony 2 mi1250 cochlear implant system

medel pte. ltd. - ear, nose & throat - the med‑el cochlear implant system is intended to evoke auditory sensations via electrical stimulation of the auditory pathways for severely to profoundly hearing-impaired individuals who obtain little or no benefit from acoustic amplification in the best aided condition. additionally, the med‑el cochlear implant system used in combination with the implant variant synchrony 2 pin flex24 and synchrony 2 pin flex20 is intended to evoke auditory sensations via electrical stimulation or via combined electric-acoustic stimulation (eas) of the auditory pathways for partially deaf individuals, who obtain benefit from acoustic amplification in the lower frequencies only. the med‑el cochlear implant system is also intended to evoke auditory sensations via electrical stimulation of the auditory pathways for individuals with single–sided deafness, which is defined as severe to profound hearing impairment in one ear and normal hearing or mild to moderate hearing impairment in the other ear.

Beckman Coulter SYNCHRON System(s) Creatinine (CRE3) Singapore - English - HSA (Health Sciences Authority)

beckman coulter synchron system(s) creatinine (cre3)

beckman coulter singapore pte. ltd. - clinical chemistry - beckman coulter cre3 reagent, in conjunction with synchron cx® delta systems and synchron cx® calibrators 1, 2 and 3, is intended for the quantitative determination of creatinine (cre3) in human serum, plasma or urine.

Beckman Coulter SYNCHRON System(s) Hemoglobin A1c3 (HbA1c3) Singapore - English - HSA (Health Sciences Authority)

beckman coulter synchron system(s) hemoglobin a1c3 (hba1c3)

beckman coulter singapore pte. ltd. - clinical chemistry - the unicel dxc synchron systems hemoglobin a1c3 (hba1c3) reagent, when used in conjunction with unicel dxc 600/800 synchron systems, unicel dxc synchron systems hba1c3 calibrators and hbdil reagent, is intended for the quantitative determination of hemoglobin a1c concentration in human whole blood. the a1c3 and hb3 values generated as part of the hba1c3 assay are intended for use in the calculation of the a1c3/hb3 ratio and must not be used individually

Beckman Coulter UniCel DxC Synchron Systems Glucose (GLUH) Singapore - English - HSA (Health Sciences Authority)

beckman coulter unicel dxc synchron systems glucose (gluh)

beckman coulter singapore pte. ltd. - clinical chemistry - gluh reagent, when used in conjunction with unicel dxc 600/800 synchron system(s) and synchron systems aqua cal 1 and 3, is intended for the quantitative determination of glucose concentration in human serum, plasma, urine or cerebrospinal fluid (csf).

SynchroMed II Clinician Programmer Application A810 - Programmer, implantable infusion pump Australia - English - Department of Health (Therapeutic Goods Administration)

synchromed ii clinician programmer application a810 - programmer, implantable infusion pump

medtronic australasia pty ltd - 44074 - programmer, implantable infusion pump - the clinician tablet, the communicator and the patient data sevices app are required to use the a810 synchromed ii clinician programmer application. the medtronic model a810 synchromed ii clinician programmer application (app) is intended for use by clinicians in the programming of the model 8637 synchromed ii programmable pump for intrathecal applications.

SynchroMed II Programmable Pump - Infusion pump, implantable, programmable Australia - English - Department of Health (Therapeutic Goods Administration)

synchromed ii programmable pump - infusion pump, implantable, programmable

medtronic australasia pty ltd - 35687 - infusion pump, implantable, programmable - the synchromed ii programmable pump is an implantable, battery-powered device that stores and dispenses drugs according to instructions programmed by the clinician. the pump has two reservoir sizes: model 8637-20 has a 20ml reservoir volume, and the model 8637-40 has a 40ml reservoir volume. indicated when patient therapy requires the chronic infusion of drugs or fluids