dynagen icd vr ? model d150 - defibrillator, implantable, automatic
boston scientific pty ltd - 35852 - defibrillator, implantable, automatic - dynagen vr?single-chamber icd provides combining ventricular tachyarrhythmia therapy with ventricular pacing and sensing. cardioversion/defibrillation therapies include a range of low- and high-energy shocks using a biphasic waveform and choice of multiple shock vectors. boston scientific implantable cardioverter defibrillators (icds) are intended to provide ventricular antitachycardia pacing (atp) and ventricular defibrillation for automated treatment of life-threatening ventricular arrhythmias.
dynagen crt-d model g158 - defibrillator, implantable, automatic
boston scientific pty ltd -
dynagen crt-d model g156 - defibrillator, implantable, automatic
boston scientific pty ltd - 35852 - defibrillator, implantable, automatic - crt-ds provide ventricular antitachycardia pacing and ventricular defibrillation for automated treatment of life-threatening ventricular arrhythmias through a range of low- and high-energy shocks using a biphasic waveform and choice of multiple shock vectors. boston scientific cardiac resynchronization therapy defibrillators (crt-ds) are indicated for patients with heart failure who receive stable optimal pharmacologic therapy (opt) for heart failure and who meet any one of the following classifications: ? moderate to severe heart failure (nyha class iii-iv) with ef ? 35% and qrs duration ? 120 ms ? left bundle branch block (lbbb) with qrs duration ? 130 ms, ef ? 30%, and mild (nyha class ii) ischemic or nonischemic heart failure or asymptomatic (nyha class i) ischemic heart failure boston scientific crt-ds are also intended to provide ventricular antitachycardia pacing and ventricular defibrillation for automated treatment of life-threatening ventricular arrhythmias.
dynagen crt-d model g151 - defibrillator, implantable, automatic
boston scientific pty ltd -
dynagen crt-d model g150 - defibrillator, implantable, automatic
boston scientific pty ltd -
dynagen icd dr – model d023 - defibrillator, implantable, automatic, dual-chamber
boston scientific pty ltd -
dynagen icd dr – model d022 - defibrillator, implantable, automatic, dual-chamber
boston scientific pty ltd -
dynagen icd dr – model d153 - defibrillator, implantable, automatic, dual-chamber
boston scientific pty ltd -
dynagen icd dr ? model d152 - defibrillator, implantable, automatic, dual-chamber
boston scientific pty ltd - 37265 - defibrillator, implantable, automatic, dual-chamber - dynogen dr?dual-chamber icd combines ventricular tachyarrhythmia therapy with ventricular and atrial pacing and sensing. cardioversion/defibrillation therapies include a range of low- and high-energy shocks using a biphasic waveform and choice of multiple shock vectors. boston scientific implantable cardioverter defibrillators (icds) are intended to provide ventricular antitachycardia pacing (atp) and ventricular defibrillation for automated treatment of life-threatening ventricular arrhythmias.
dynagen icd vr – model d021 - defibrillator, implantable, automatic