Trekking Tibial Component MB - Cemented - Uncoated knee tibia prosthesis, metallic Australia - English - Department of Health (Therapeutic Goods Administration)

trekking tibial component mb - cemented - uncoated knee tibia prosthesis, metallic

orthotech pty ltd - 32832 - uncoated knee tibia prosthesis, metallic - the cemented cocrmo mobile tibial component has a keeled tibial plate component with a flat, mirror polished upper surface for tibial liner articulation. the internal truncated conical cavity in the keel accommodates the liner peg, partially constraining the liner while allowing rotation based on a central-pivot design. the height of the peg prevents dislocation and its design minimises polyethylene wear. the plate has a 0? posterior and 6? articular surface slope. the trekking tibial component mb ? cemented is a component of the trekking total knee replacement system which is a modular system that provides an optimal fit between the replaced joint and the limb. indications: - knee arthrosis - extensive primary and secondary destruction of the joint to the extent that the functional efficiency of the locomotive apparatus is reduced; - severe pathological condition affecting the articulation caused by degenerative and rheumatoid arthritis; - joint fracture or bone necrosis; post-surgical conditions after previous operations with or without consequent use of a prosthesis. the mobile bearing knee system is indicated in relatively young and active patients with good ligaments.

Trekking Tibial Component MBHollow - Uncemented - Coated knee tibia prosthesis Australia - English - Department of Health (Therapeutic Goods Administration)

trekking tibial component mbhollow - uncemented - coated knee tibia prosthesis

orthotech pty ltd - 34198 - coated knee tibia prosthesis - the uncemented mobile-tibial component, keeled tibial plate has a flat, mirror-polished floor for tibial liner articulation; the lack of additional surface spines, ripples or screw-holes minimises pe liner wear. the ti+ha coated undersurface promotes osteointegration. the internal truncated conical cavity in the keel accommodates the liner peg, partially constraining the liner while allowing rotation based on a central-pivot design. the plate has a 0? posterior and 6? articular surface slope. the trekking femoral component mb ? uncemented is a component of the trekking total knee replacement system which is a modular system that provides an optimal fit between the replaced joint and the limb. indications: - knee arthrosis - extensive primary and secondary destruction of the joint to the extent that the functional efficiency of the locomotive apparatus is reduced; - severe pathological condition affecting the articulation caused by degenerative and rheumatoid arthritis; - joint fracture or bone necrosis; post-surgical conditions after previous operations with or without consequent use of a prosthesis.

Trekking Femoral Component PS - Cemented - Uncoated knee femur prosthesis Australia - English - Department of Health (Therapeutic Goods Administration)

trekking femoral component ps - cemented - uncoated knee femur prosthesis

orthotech pty ltd - 32831 - uncoated knee femur prosthesis - the cemented cocrmo ps femoral component has a grooved surface (the cam) that articulates at the centre of the tibial liner, a condylar profile with a single sagittal radius for each condyle running from 10? of hyperextension to 70? flexion vs a single radius on the frontal plane. the external contact surfaces are mirror polished; the internal surfaces have a high degree of roughness, sandblasted to enhance contact & so adhesion/fixation with the bone cement. use with the removal of the pcl. the trekking femoral component ps ? cemented is a component of the trekking total knee replacement system which is a modular system that provides an optimal fit between the replaced joint and the limb. indications: - knee arthrosis - extensive primary and secondary destruction of the joint to the extent that the functional efficiency of the locomotive apparatus is reduced; - severe pathological condition affecting the articulation caused by degenerative and rheumatoid arthritis; - joint fracture or bone necrosis; post-surgical conditions after previous operations with or without consequent use of a prosthesis.

Trekking Femoral Component CR - Cemented - Uncoated knee femur prosthesis Australia - English - Department of Health (Therapeutic Goods Administration)

trekking femoral component cr - cemented - uncoated knee femur prosthesis

orthotech pty ltd - 32831 - uncoated knee femur prosthesis - the cemented cocrmo cr femoral component allows preservation of the pcl when is coupled to fb fixed tibial component. the intercondylar area is hollow to accommodate the pcl, the condylar profile features a single sagittal radius for each condyle running from 10? of hyperextension to 70? flexion vs a single radius on the frontal plane. the external contact surfaces are mirror polished; the internal anchoring surfaces are rough with a double porous coating of ti + ha. the trekking femoral component cr ? cemented is a component of the trekking total knee replacement system which is a modular system that provides an optimal fit between the replaced joint and the limb. indications: - knee arthrosis - extensive primary and secondary destruction of the joint to the extent that the functional efficiency of the locomotive apparatus is reduced; - severe pathological condition affecting the articulation caused by degenerative and rheumatoid arthritis; - joint fracture or bone necrosis; post-surgical conditions after previous operations with or without consequent use of a prosthesis.

Trekking Femoral Component CR - Uncemented - Coated knee femur prosthesis Australia - English - Department of Health (Therapeutic Goods Administration)

trekking femoral component cr - uncemented - coated knee femur prosthesis

orthotech pty ltd - 33745 - coated knee femur prosthesis - the uncemented, press-fit cocrmo cr femoral component allows preservation of the pcl when is coupled to fb fixed tibial component. the intercondylar area is hollow to accommodate the pcl, the condylar profile features a single sagittal radius for each condyle running from 10? of hyperextension to 70? flexion vs a single radius on the frontal plane. the external contact surfaces are mirror polished; the internal anchoring surfaces are rough with a double porous coating of ti + ha. the trekking femoral component cr ? uncemented is a component of the trekking total knee replacement system which is a modular system that provides an optimal fit between the replaced joint and the limb. indications: - knee arthrosis - extensive primary and secondary destruction of the joint to the extent that the functional efficiency of the locomotive apparatus is reduced; - severe pathological condition affecting the articulation caused by degenerative and rheumatoid arthritis; - joint fracture or bone necrosis; post-surgical conditions after previous operations with or without consequent use of a prosthesis.

Trekking Femoral Component PS - Uncemented - Coated knee femur prosthesis Australia - English - Department of Health (Therapeutic Goods Administration)

trekking femoral component ps - uncemented - coated knee femur prosthesis

orthotech pty ltd - 33745 - coated knee femur prosthesis - the uncemented cocrmo press-fit ps femoral component has a grooved surface (the cam) that articulates on the centre of the tibial liner (post tibial), & a condylar profile with a single sagittal radius for each condyle running from 10? of hyperextension to 70? flexion vs a single radius on the frontal plane. the external contact surfaces are mirror polished; the internal anchoring surfaces are rough with a double porous coating of ti + ha. use with the removal of the posterior cruciate ligament. the trekking femoral component ps ? uncemented is a component of the trekking total knee replacement system which is a modular system that provides an optimal fit between the replaced joint and the limb. indications: - knee arthrosis - extensive primary and secondary destruction of the joint to the extent that the functional efficiency of the locomotive apparatus is reduced; - severe pathological condition affecting the articulation caused by degenerative and rheumatoid arthritis; - joint fracture or bone necrosis; post-surgical conditions after previous operations with or without consequent use of a prosthesis.

Trekking TCK Tibial Offset Adaptor - Knee stem Australia - English - Department of Health (Therapeutic Goods Administration)

trekking tck tibial offset adaptor - knee stem

orthotech pty ltd - 48066 - knee stem - a ti6al4v tapered l/r tibial offset adaptor with safety screw is a modular offset for revision. it is used with the fb modular baseplate to host im cemented/uncemented stems and can be used with the tck range of trekking tibial component, tck-u and tck-c range of trekking cemented and uncemented stems. they are radially 360? - adjustable and available in 3 different offset values. the trekking tck tibial offset adaptor is a modular offset for revision knee replacement procedures. it is a component of the trekking total knee system which is a modular system that provided an optimal fit between the replaced joint and the limb. the trekking tck tkr system is intended to treat difficult primary and revision cases requiring total knee replacement. indications: - knee arthrosis - extensive primary and secondary destruction of the joint to the extent that the functional efficiency of the locomotive apparatus is reduced; - severe pathological condition affecting the articulation caused by degenerative and rheumatoid arthritis; - joint fracture or bone necrosis; - post-surgical conditions after previous operations with or without consequent use of a prosthesis.

Trekking TCK Femoral Offset Adaptor - Knee stem Australia - English - Department of Health (Therapeutic Goods Administration)

trekking tck femoral offset adaptor - knee stem

orthotech pty ltd - 48066 - knee stem - a cocrmo alloy tapered l/r offset adaptor with safety screw which is interposed between the tck femoral component & the im stem providing the geometry of the tapered male (offset-to-femur and stem-to-offset)/female (femur-to-offset and offset-to-stem) parts. the offset adaptor can be coupled with the tck range of trekking femoral components, tck-u and tck-c range of trekking cemented and uncemented stems. the trekking tck femoral offset adaptor is a modular offset for revision knee replacement procedures. it is a component of the trekking total knee system which is a modular system that provided an optimal fit between the replaced joint and the limb. the trekking tck tkr system is intended to treat difficult primary and revision cases requiring total knee replacement. indications: - knee arthrosis - extensive primary and secondary destruction of the joint to the extent that the functional efficiency of the locomotive apparatus is reduced; - severe pathological condition affecting the articulation caused by degenerative and rheumatoid arthritis; - joint fracture or bone necrosis; - post-surgical conditions after previous operations with or without consequent use of a prosthesis.

Trekking TCK-Flex-VIT? Tibial Insert FB PS - Prosthesis, knee, internal, insert component Australia - English - Department of Health (Therapeutic Goods Administration)

trekking tck-flex-vit? tibial insert fb ps - prosthesis, knee, internal, insert component

orthotech pty ltd - 46585 - prosthesis, knee, internal, insert component - the symmetric, fixed-bearing uhmwpe tibial liner with pcl sacrifice and low coronal rotational constraint. minimum thickness is 6mm. the lower part of the liner is equipped with a system to secure it to the tibial plateau. this system features a steel wire spring fitted within the notches on the edge of the tibial plateau. the liner acts as the articular surface for the corresponding surface of the femoral component. the trekking tck-flex-vit? tibial insert fb ps is intended to treat difficult primary and revision cases requiring total knee replacement. it is a component of the trekking total knee replacement system which is a modular system that provides an optimal fit between the replaced joint and the limb. indications: - knee arthrosis - extensive primary and secondary destruction of the joint to the extent that the functional efficiency of the locomotive apparatus is reduced; - severe pathological condition affecting the articulation caused by degenerative and rheumatoid arthritis; - joint fracture or bone necrosis; post-surgical conditions after previous operations with or without consequent use of a prosthesis.

Trekking TCK-Flex Tibial Insert FB PS - Prosthesis, knee, internal, insert component Australia - English - Department of Health (Therapeutic Goods Administration)

trekking tck-flex tibial insert fb ps - prosthesis, knee, internal, insert component

orthotech pty ltd - 46585 - prosthesis, knee, internal, insert component - symmetric, fixed-bearing uhmwpe tibial liner with pcl sacrifice and low coronal rotational constraint. minimum thickness is 6mm. the lower part of the liner is equipped with a system to secure it to the tibial plateau. this system features a steel wire spring fitted within the notches on the edge of the tibial plateau. the liner acts as the articular surface for the corresponding surface of the femoral component. the trekking tck-flex tibial insert fb ps is intended to treat difficult primary and revision cases requiring total knee replacement. it is a component of the trekking total knee replacement system which is a modular system that provides an optimal fit between the replaced joint and the limb. indications: - knee arthrosis - extensive primary and secondary destruction of the joint to the extent that the functional efficiency of the locomotive apparatus is reduced; - severe pathological condition affecting the articulation caused by degenerative and rheumatoid arthritis; - joint fracture or bone necrosis; post-surgical conditions after previous operations with or without consequent use of a prosthesis.