ACTIVA RC 37612 - Stimulator, electrical, brain, tremor Australia - English - Department of Health (Therapeutic Goods Administration)

activa rc 37612 - stimulator, electrical, brain, tremor

medtronic australasia pty ltd - 37307 - brain electrical stimulation system, antitremor - the model 37612 activa rc is an implantable, multiprogrammable, rechargeable device that delivers electrical stimulation through one or two leads implanted in the brain. the neurostimulator is typically implanted in the pectoral region. the device is indicated for stimulation of the ventral intermediate nucleus for patients with disabling essential tremor or parkinsonian tremor, or stimulation of the internal globus pallidus or the subthalamic nucleus for patients with symptoms of parkinson's disease. studies have shown that deep brain stimulation with the medtronic dbs therapy system is effective in controlling essential tremor and symptoms of parkinson's disease that are not adequately controlled with medications. additionally, dbs is effective in controlling dyskinesias and fluctuations associated with medical therapy for parkinson's disease. medtronic dbs therapy for movement disorders is also indicated for stimulation of the internal globus pallidus or the subthalamic nucleus as an aid in the management

Activa SC 37602 Multi-program Neurostimulator - Brain electrical stimulation system, antitremor Australia - English - Department of Health (Therapeutic Goods Administration)

activa sc 37602 multi-program neurostimulator - brain electrical stimulation system, antitremor

medtronic australasia pty ltd - 37307 - brain electrical stimulation system, antitremor - the neurostimulator is a quadripolar, multi-program device that delivers stimulation through one lead. the stimulation settings are stored in programs which are specific combinations of pulse width, rate and amplitude. the device is indicated for stimulation of the ventral intermediate nucleus for patients with disabling essential tremor or parkinsonian tremor, or stimulation of the internal globus pallidus or the subthalamic nucleus for patients with symptoms of parkinson's disease. studies have shown that deep brain stimulation with the medtronic dbs therapy system is effective in controlling essential tremor and symptoms of parkinson's disease that are not adequately controlled with medications. additionally, dbs is effective in controlling dyskinesias and fluctuations associated with medical therapy for parkinson's disease. medtronic dbs therapy for movement disorders is also indicated for stimulation of the internal globus pallidus or the subthalamic nucleus as an aid in the management of chronic, intrac

Activa SC 37603 Muli-program neurostimulator - Brain electrical stimulation system, antitremor Australia - English - Department of Health (Therapeutic Goods Administration)

activa sc 37603 muli-program neurostimulator - brain electrical stimulation system, antitremor

medtronic australasia pty ltd - 37307 - brain electrical stimulation system, antitremor - the neurostimulator is a octapolar, multi-program device that delivers stimulation through one lead. the stimulation settings are stored in programs which are specific combinations of pulse width, rate and amplitude. the device is indicated for stimulation of the ventral intermediate nucleus for patients with disabling essential tremor or parkinsonian tremor, or stimulation of the internal globus pallidus or the subthalamic nucleus for patients with symptoms of parkinson's disease. studies have shown that deep brain stimulation with the medtronic dbs therapy system is effective in controlling essential tremor and symptoms of parkinson's disease that are not adequately controlled with medications. additionally, dbs is effective in controlling dyskinesias and fluctuations associated with medical therapy for parkinson's disease. medtronic dbs therapy for movement disorders is also indicated for stimulation of the internal globus pallidus or the subthalamic nucleus as an aid in the management of chronic, intracta

Active-implantable-device communicator Australia - English - Department of Health (Therapeutic Goods Administration)

active-implantable-device communicator

medtronic australasia pty ltd - 45252 - active-implantable-device communicator - the medtronic external patient programmer antenna is a detachable optional extra to be used with patient programmers for those patients who have difficulty reaching their implanted neurostimulator.

Adaptor, <specify> Australia - English - Department of Health (Therapeutic Goods Administration)

adaptor, <specify>

medtronic australasia pty ltd - 35074 - adaptor, - the medtronic affinity? cp adapter is intended to be used to enable the medtronic affinity? cp centrifugal blood pumps (model ap40, model bbap40, and model cbap40) to be operated with the st?ckert? and sorin? centrifugal pump systems or the sarns? and terumo? centrifugal systems.

Adaptor, cable, electrosurgical unit Australia - English - Department of Health (Therapeutic Goods Administration)

adaptor, cable, electrosurgical unit

medtronic australasia pty ltd - 35041 - adaptor, cable, electrosurgical unit - the medtronic catheter connecting cable is intended for use during diagnostic electrophysiology studies in conjunction with medtronic electrode catheters or for cardiac ablation when used with medtronic's rf ablation catheters. the cable is used during electrophysiology studies to connect the electrode catheter to the ecg recording/stimulation equipment.

Advisa DR MRI SureScan A3DR01  - Pacemaker, cardiac, implantable Australia - English - Department of Health (Therapeutic Goods Administration)

advisa dr mri surescan a3dr01 - pacemaker, cardiac, implantable

medtronic australasia pty ltd - 12913 - pacemaker, cardiac, implantable - the medtronic model a3dr01 advisa dr mri surescan dual chamber implantable pacemaker is a multiprogrammable cardiac device that monitors and regulates the patient's heart rate by providing single or dual chamber rate-responsive bradycardia pacing and atrial tachyarrhythmia therapies. the mri surescan pacing feature allows the patient to be safely scanned while the device continues to provide appropriate pacing. the advisa dr mri surescan system is indicated to restore physiologic heart rates, improve cardiac output, prevent symptoms, or protect against arrhythmias related to cardiac impulse formation or conduction disorders. the device is indicated for use in patients who may benefit from rate-responsive pacing to support cardiac output during varying levels of activity.

Ascenda Intrathecal Catheter 8780 - Spinal catheter Australia - English - Department of Health (Therapeutic Goods Administration)

ascenda intrathecal catheter 8780 - spinal catheter

medtronic australasia pty ltd - 47079 - spinal catheter - the catheter consists of a spinal segment and pump segment with a sutureless pump connector. these segments connect to each other with a catheter connector and collets. the pump segment connects to the pump with the sutureless pump connector. the package contains spinal segemnt with inserted guide wire, pump segment with attached sutureless pump connector, catheter connector with 2 attached collets, 16 t-gauge introducer needle, anchor with anchor dispenser, ruler, product literature. the implantable medtronic model 8780 ascenda catheter is part of an infusion system that stores and delivers parenteral drugs to the intrathecal space. the implanted infusion system components consist of a medtronic pump and a model 8780 ascenda intrathecal catheter. the catheter connects to the pump and the catheter port.

Ascenda Intrathecal Catheter 8781 - Spinal catheter Australia - English - Department of Health (Therapeutic Goods Administration)

ascenda intrathecal catheter 8781 - spinal catheter

medtronic australasia pty ltd - 47079 - spinal catheter - the catheter consists of a spinal segment and pump segment with a sutureless pump connector. these segments connect to each other with a catheter connector and collets. the pump segment connects to the pump with the sutureless pump connector. the package contains spinal segemnt with inserted guide wire, pump segment with attached sutureless pump connector, catheter connector with 2 attached collets, 16 t-gauge introducer needle, anchor with anchor dispenser, ruler, product literature. the implantable medtronic model 8781 ascenda intrathecal catheter is part of an infusion system that stores and delivers parenteral drugs to the intrathecal space.

Ascenda Intrathecal Catheter Pump Segment Revision Kit 8784 - Spinal catheter Australia - English - Department of Health (Therapeutic Goods Administration)

ascenda intrathecal catheter pump segment revision kit 8784 - spinal catheter

medtronic australasia pty ltd - 47079 - spinal catheter - this pump segment of the catheter connects to the spinal segement of the catheter with a catheter connector and collets. the kit contains pump segment with attached sutureless pump connector, catheter connector with 2 attached collets, ruler and product literature. the medtronic model 8784 ascenda pump segment revision kit is used when a revision to the pump segment of a model 8780 or model 8781 ascenda intrathecal catheter is required. the catheter is part of an infusion system that stores and delivers parenteral drugs to the intrathecal space. the implanted infusion system components consist of a medtronic pump and a model 8780 or model 8781 ascenda intrathecal catheter. the catheter connects to the pump at the catheter port.