Binder, abdominal Australia - English - Department of Health (Therapeutic Goods Administration)

binder, abdominal

hjorth health pty ltd - 10003 - abdominal binder, single-use - the qualibelly abdominal binder is to be used as a compression and support to patients upper,lower and flank area postoperatively following abdominal surgery, abdominoplasty,weight loss surgery or cesarean section.

Endurant II Stent Graft System - Abdominal aortic aneurysm stent Australia - English - Department of Health (Therapeutic Goods Administration)

endurant ii stent graft system - abdominal aortic aneurysm stent

medtronic australasia pty ltd - 46777 - abdominal aortic aneurysm stent - the stent graft system when placed within the target lesion, provides a permanent, alternative conduit for blood flow within the patient's vasculature by excluding the lesion from blood flow and pressure. the stent graft is preloaded into the delivery system and advanced to the aneurysm using fluoroscopic guidance. upon deployment, the stent graft self-expands to conform to the shape and size of the seal zones above and below the aneurysm. the device is a graft system indicated for the endovascular treatment of infrarenal or juxtarenal aortic or aortoiliac aneurysms (with the parallel graft technique) in patients with the following characteristics - adequate iliac or femoral access vessel morphology that is compatible with vascular access techniques, devices, or accessories; iliac distal fixation length of ?15 mm; iliac diameters with a range of 8 to 25 mm; morphology suitable for aneurysm repair; one of the following: aneurysm diameter >5 cm or aneurysm diameter of 4 to 5 cm, which has also increased in size by 0.5 cm in the last 6 months or aneurysm that is at least 1.5 times the diameter of the normal infrarenal aorta. in addition, for treatment of infrarenal abdominal aortic or aortoiliac aneurysms, the following patient characteristics apply: proximal neck length of ?10 mm or ?4 mm and <10 mm when used in conjunction with the heli-fx endoanchor system, with insignificant calcification, or insignificant thrombus with ?60? infrarenal and ?45? suprarenal angulation and a vessel diameter approximately 10% to 20% smaller than the labelled endurant ii stent graft diameter.

Endurant II Stent Graft System - Bifurcated  - Abdominal aortic aneurysm stent Australia - English - Department of Health (Therapeutic Goods Administration)

endurant ii stent graft system - bifurcated - abdominal aortic aneurysm stent

medtronic australasia pty ltd - 46777 - abdominal aortic aneurysm stent - the endurant ii stent graft system is comprised of the endurant ii stent graft and the endurant ii delivery system. the stent graft is compressed and held constrained on the delivery system as it is advanced to the aneurysm location over a guidewire. as deployment occurs , the graft self expands to cover the aneurysm. the endurant ii stent graft system is indicated for the endovascular treatment of infrarenal abdominal aortic or aortoiliac aneurysms. when placed within the aneurysm, the endurant ii stent graft provides a permanent, alternative conduit for blood flow within the patient's vasculature by excluding the aneurysmal sac from blood flow and pressure.

Endurant II Stent Graft System ? Limb - Abdominal aortic aneurysm stent Australia - English - Department of Health (Therapeutic Goods Administration)

endurant ii stent graft system ? limb - abdominal aortic aneurysm stent

medtronic australasia pty ltd - 46777 - abdominal aortic aneurysm stent - the endurant ii stent graft system is comprised of the endurant ii stent graft and the endurant ii delivery system. the stent graft is compressed and held constrained on the delivery system as it is advanced to the aneurysm location over a guidewire. as deployment occurs , the graft self expands to cover the aneurysm. the intended use of the endurant ii stent graft system is to repair infrarenal abdominal aortic or aortoiliac aneurysms, or juxtarenal abdominal aortic or aortoiliac aneurysms (with a parallel graft technique), in an endovascular approach by providing an alternative conduit for blood flow within the patient?s vessel (aorta and iliac arteries) by excluding the aneurysm (target lesion).