Country: United States
Language: English
Source: NLM (National Library of Medicine)
Trisodium Citrate Dihydrate (UNII: B22547B95K) (Anhydrous Citric Acid - UNII:XF417D3PSL), Dextrose Monohydrate (UNII: LX22YL083G) (ANHYDROUS DEXTROSE - UNII:5SL0G7R0OK), Anhydrous Citric Acid (UNII: XF417D3PSL) (Anhydrous Citric Acid - UNII:XF417D3PSL), Sodium Phosphate, Monobasic, Monohydrate (UNII: 593YOG76RN) (PHOSPHATE ION - UNII:NK08V8K8HR)
Fenwal, Inc.
PRESCRIPTION DRUG
New Drug Application
ADSOL RED CELL PRESERVATION SOLUTION SYSTEM IN PLASTIC CONTAINER (PL 146 PLASTIC)- ANTICOAGULANT CITRATE PHOSPHATE DEXTROSE (CPD) SOLUTION AND ADSOL PRESERVATION SOLUTION FENWAL, INC. ---------- 4R3428, 4R3429 FRESENIUS KABI FENWAL BLOOD-PACK UNITS RX ONLY USING ANTICOAGULANT CITRATE PHOSPHATE DEXTROSE SOLUTION, USP (CPD) WITH AN INTEGRALLY ATTACHED CONTAINER OF ADSOL RED CELL PRESERVATION SOLUTION AND FENWAL HIGHFLO NEEDLE Contains Y-Sampling Site for the collection of unanticoagulated whole blood samples for laboratory testing. INSTRUCTIONS FOR USE COLLECTION PROCEDURE: USE ASEPTIC TECHNIQUE. NOTE: If the Y-Sampling Site is not used, donor samples may be collected using an alternate method following standard procedures. • • 6. Following blood center procedures, perform venipuncture, appropriately secure donor needle and/or tubing and release clamp on donor tubing. 7. When good blood flow is established, stabilize the front of the needle guard to arm with tape. (see Figure 1) 8. FOLLOWING BLOOD CENTER PROCEDURES, MIX BLOOD AND ANTICOAGULANT IN PRIMARY CONTAINER AT SEVERAL INTERVALS DURING COLLECTION AND IMMEDIATELY AFTER NOTE: Nominal tubing dimensions of product are 0.118" inner diameter x 0.025" wall thickness. PRECAUTIONS: • DO NOT USE UNLESS THE SOLUTIONS ARE CLEAR. • BEFORE BEGINNING PROCEDURE, OBTAIN ONE ACCESS DEVICE FOR EACH BLOOD- PACK UNIT WITH Y-SAMPLING SITE TO BE PROCESSED. 1. Identify Blood-Pack unit using appropriate donor identification system. 2. Adjust donor scale to desired collection weight and position primary container on the donor scale as far as possible below donor arm. 3. Clamp donor tubing between Fenwal HighFlo needle and primary container. This step may be performed prior to step 1 or 2. 1 4. Following blood center procedures, apply pressure to donor’s arm and disinfect site of venipuncture. 5. Remove needle cover per instructions below: Holding the hub and cover near the tamper-evident seal, twist cover and hub in opposite directions to break seal. Remove needle cover, bei Read the complete document