NexGen? Complete Knee Solution, Trabecular Metal? Standard Primary Patella - Metal-backed patella prosthesis Austrálie - angličtina - Department of Health (Therapeutic Goods Administration)

nexgen? complete knee solution, trabecular metal? standard primary patella - metal-backed patella prosthesis

zimmer biomet pty ltd - 34192 - metal-backed patella prosthesis - monoblock constructs comprised of a trabecular metal base with a central hexagonal shaped post for initial fixation, and direct compression molded polyethylene for the articulating surface. variations in patient size and shape may be accommodated by choice of implant size. made from tantalum (trabecular metal) and ultra-high-molecular-weight-polyethylene (uhmwpe). the nexgen? trabecular metal primary standard patella is intended for use where severe degeneration, trauma, or other pathology of the knee joint indicates cemented or cementless total knee arthroplasty.

NexGen Complete Knee Solution Rotating Hinge Knee Tibial Component, Precoat Nonmodular - Uncoated knee tibia prosthesis, metallic Austrálie - angličtina - Department of Health (Therapeutic Goods Administration)

nexgen complete knee solution rotating hinge knee tibial component, precoat nonmodular - uncoated knee tibia prosthesis, metallic

zimmer biomet pty ltd - 32832 - uncoated knee tibia prosthesis, metallic - tibial component of the nexgen rotating hinge knee prosthesis system intended for flexion/extension and internal/external rotation between the femoral and tibial components, but is constrained in the anterior/posterior and medial/lateral directions by means of a femoral hinge post extension. tibial components are made from zimaloy® cobalt-chromium-molybdenum alloy and are for non-modular cemented use only. intended to repair or replace the tibial knee joint, for patients with mderate to severe knee instability, significant bone loss and/or ligament deficiencies caused by neoplasms, trauma, rheumatoid arthritis, osteoarthritis, traumatic arthritis, polyarthritis, collagen disorders, and/or avascular necrosis of the femoral condyle, valgus, varus, or flexion deformities, the salvage of previously failed surgical attempts.

NexGen? Complete Knee Solution Legacy? Knee ? Posterior Stabilized (LPS) All-Poly Stemmed Tibial Component - Uncoated knee tibia prosthesis, polyethylene Austrálie - angličtina - Department of Health (Therapeutic Goods Administration)

nexgen? complete knee solution legacy? knee ? posterior stabilized (lps) all-poly stemmed tibial component - uncoated knee tibia prosthesis, polyethylene

zimmer biomet pty ltd - 33580 - uncoated knee tibia prosthesis, polyethylene - stemmed tibial component of the nexgen? semiconstrained, nonlinked condylar knee prostheses system designed for replacing the tibial articulating surface of human knees in total knee arthroplasty to relieve pain and restore joint function. it is manufactured from ultra-high molecular weight polyethylene and is indicated for cemented use only. indicated for patients with severe knee pain and disability due to: rheumatoid arthritis, osteoarthritis, traumatic arthritis, polyarthritis. collagen disorders, and/or avascular necrosis of the femoral condyle, post-traumatic loss of joint configuration, particularly when there is patellofemoral erosion, dysfunction or prior patellectomy. moderate valgus, varus, or flexion deformities. the salvage of previously failed surgical attempts or for a knee in which satisfactory stability in flexion cannot be obtained at the time of surgery.

NexGen? Complete Knee Solution  Legacy? Posterior Stabilized LPS-Flex  Femoral Components Porous - Coated knee femur prosthesis Austrálie - angličtina - Department of Health (Therapeutic Goods Administration)

nexgen? complete knee solution legacy? posterior stabilized lps-flex femoral components porous - coated knee femur prosthesis

zimmer biomet pty ltd - 33745 - coated knee femur prosthesis - posterior stabilising femoral component of the nexgen? flex fixed bearing semiconstrained, nonlinked condylar knee prostheses system designed for use with both cruciate ligaments excised and when load bearing range of motion if expected to be less than or equal to 155 degrees. manufactured from zimaloy cobalt-chromium-molybdenum alloy, for cemented or uncemented use. indicated for patients with severe knee pain and disability due to rheumatoid arthritis, osteoarthritis, traumatic arthritis, polyarthritis, collagen disorders, and/or avascular necrosis of the femoral condyle, post-traumatic loss of joint configuration, particularly when there is patellofemoral erosion, dysfunction or prior patellectomy, moderate valgus, varus, or flexion deformities, or the salvage of previously failed surgical attempts or for a knee in which satisfactory stability in flexion cannot be obtained at the time of surgery.

NexGen? Complete Knee Solution Legacy? Knee PS LPS-Flex Femoral Component Precoat  Compatible w LPS-Flex Prolong - Uncoated knee femur prosthesis Austrálie - angličtina - Department of Health (Therapeutic Goods Administration)

nexgen? complete knee solution legacy? knee ps lps-flex femoral component precoat compatible w lps-flex prolong - uncoated knee femur prosthesis

zimmer biomet pty ltd - 32831 - uncoated knee femur prosthesis - precoate femoral component of the nexgen? flex fixed bearing semiconstrained, nonlinked condylar knee prostheses system designed to have a maximum active flexion of 155 degrees. the component has an nextended posterior condyle radius, which provides greater tibio-femoral contact area in deep flexion. manufactured from zimaloy cobalt-chromium-molybdenum alloy, with a poly(methylmethacrylate) [pmma] precoat. indicated for cemented use only. for severe knee pain & disability due to rheumatoid arthritis, osteoarthritis, traumatic arthritis, polyarthritis. collagen disorders &/or avascular necrosis of femoral condyle. post-traumatic loss of joint configuration particularly when there is patellofemoral erosion, dysfunction or prior patellectomy. moderate valgus, varus, or flexion deformities. salvage of previously failed surgical attempts or for a knee in which satisfactory stability in flexion cannot be obtained at the time of surgery

NexGen? Complete Knee Solution Legacy? Knee LPS Femoral Component, Precoat  - Uncoated knee femur prosthesis Austrálie - angličtina - Department of Health (Therapeutic Goods Administration)

nexgen? complete knee solution legacy? knee lps femoral component, precoat - uncoated knee femur prosthesis

zimmer biomet pty ltd - 32831 - uncoated knee femur prosthesis - porous coated femoral component of the nexgen? semiconstrained, nonlinked condylar knee prostheses system designed for use with both cruciate ligaments excised and when load bearing rom is expected to be less than or equal to 130 degrees. precoated with poly (methylmethacrylate) [pmma]. manufactured from zimaloy? cobalt-chromium-molybdenum alloy and indicated for cemented use only intended to repair or replace the femoral knee joint for patients with severe knee pain and disability due to: rheumatoid arthritis, osteoarthritis, traumatic arthritis, polyarthritis. collagen disorders, and/or avascular necrosis of the femoral condyle. post-traumatic loss of joint configuration, particularly when there is patellofemoral erosion, dysfunction or prior patellectomy. moderate valgus, varus, or flexion deformities. the salvage of previously failed surgical attempts or for a knee in which satisfactory stability in flexion cannot be obtained at the time of surgery.

NexGen? Complete Knee Solution, CR Articular Surface, Anterior Constrained  - Prosthesis, knee, internal, insert component Austrálie - angličtina - Department of Health (Therapeutic Goods Administration)

nexgen? complete knee solution, cr articular surface, anterior constrained - prosthesis, knee, internal, insert component

zimmer biomet pty ltd - 46585 - prosthesis, knee, internal, insert component - anterior constrained, cruciate ligament retaining articulating surface component of the nexgen? semiconstrained, nonlinked condylar knee prostheses system available in multiple thicknesses to facilitate soft tissue tensioning and joint line restoration. it is made from conventional ultra-high molecular weight polyethylene (uhmwpe). indicated for patients with severe knee pain and disability due to: rheumatoid arthritis, osteoarthritis, traumatic arthritis, polyarthritis. collagen disorders, and/or avascular necrosis of the femoral condyle, post-traumatic loss of joint configuration, particularly when there is patellofemoral erosion, dysfunction or prior patellectomy. moderate valgus, varus, or flexion deformities. the salvage of previously failed surgical attempts or for a knee in which satisfactory stability in flexion cannot be obtained at the time of surgery. the salvage of previously failed surgical attempts or for a knee in which satisfactory stability in flexion cannot be obtained at the time of surgery.

NexGen? Complete Knee Solution, Legacy PS LPS-Flex, (GSF) Femoral Component, Porous - Coated knee femur prosthesis Austrálie - angličtina - Department of Health (Therapeutic Goods Administration)

nexgen? complete knee solution, legacy ps lps-flex, (gsf) femoral component, porous - coated knee femur prosthesis

zimmer biomet pty ltd - 33745 - coated knee femur prosthesis - posterior stabilising femoral component part of the nexgen semi-constrained, non-linked condylar knee system for use when both cruciate ligaments excised and when load bearing range of motion is expected to be less than or equal to 155 degrees. designed to address specific anatomic features of the distal femur that can be seen in both male and female patients, but are typical of a female patient. manufactured from zimaloy? cobalt-chromium-molybdenum alloy. indicated for patients with severe knee pain and disability due to rheumatoid arthritis, osteoarthritis, traumatic arthritis, polyarthritis, collagen disorders, and/or avascular necrosis of the femoral condyle, post-traumatic loss of joint configuration, particularly when there is patellofemoral erosion, dysfunction or prior patellectomy, moderate valgus, varus, or flexion deformities, the salvage of previously failed surgical attempts or for a knee in which satisfactory stability in flexion cannot be obtained at the time of surgery.

NexGen? Complete Knee Solution, Stemmed Nonaugmentable Tibial Component, Option - Uncoated knee tibia prosthesis, metallic Austrálie - angličtina - Department of Health (Therapeutic Goods Administration)

nexgen? complete knee solution, stemmed nonaugmentable tibial component, option - uncoated knee tibia prosthesis, metallic

zimmer biomet pty ltd - 32832 - uncoated knee tibia prosthesis, metallic - stemmed nonaugmentable tibial component of the the nexgen? semiconstrained, nonlinked condylar knee system. it is made from tivanium? ti-6al-4v alloy and indicated for cemented use only. intended to repair or replace the tibial knee joint, for patients with severe knee pain and disability due to: rheumatoid arthritis, osteoarthritis, traumatic arthritis, polyarthritis. collagen disorders, and/or avascular necrosis of the femoral condyle, post-traumatic loss of joint configuration, particularly when there is patellofemoral erosion, dysfunction or prior patellectomy. moderate valgus, varus, or flexion deformities. the salvage of previously failed surgical attempts or for a knee in which satisfactory stability in flexion cannot be obtained at the time of surgery.

NexGen? Complete Knee Solution, Cruciate Retaining (CR), Pegged Tibial Component, Precoat - Uncoated knee tibia prosthesis, metallic Austrálie - angličtina - Department of Health (Therapeutic Goods Administration)

nexgen? complete knee solution, cruciate retaining (cr), pegged tibial component, precoat - uncoated knee tibia prosthesis, metallic

zimmer biomet pty ltd - 32832 - uncoated knee tibia prosthesis, metallic - cruciate ligament retaining (cr) precoated, pegged tibial component of the the nexgen? semiconstrained, nonlinked condylar knee system. it is made from tivanium? ti-6al-4v alloy and indicated for cemented use only. intended to repair or replace the tibial knee joint, for patients with severe knee pain and disability due to: rheumatoid arthritis, osteoarthritis, traumatic arthritis, polyarthritis. collagen disorders, and/or avascular necrosis of the femoral condyle, post-traumatic loss of joint configuration, particularly when there is patellofemoral erosion, dysfunction or prior patellectomy. moderate valgus, varus, or flexion deformities. the salvage of previously failed surgical attempts or for a knee in which satisfactory stability in flexion cannot be obtained at the time of surgery.