NexGen? Complete Knee Solution Legacy? Knee LPS Femoral Component, Porous - Coated knee femur prosthesis Austrálie - angličtina - Department of Health (Therapeutic Goods Administration)

nexgen? complete knee solution legacy? knee lps femoral component, porous - coated knee femur prosthesis

zimmer biomet pty ltd - 33745 - coated knee femur prosthesis - the nexgen legacy ?knee lps femoral component is a porous, semi-constrained, non-linked condylar knee prosthesis made from zimaloy cobalt-chromium-molybdenum alloy intended for patients who, in the surgeon?s judgement, have adequate bone stock and varus/valgus stability, and/or when the surgeon elects to substitute for the posterior cruciate ligament. fixation method is porous fibre metal, cemented or uncemented (biological fixation). femoral component of the nexgen? complete knee solution legacy? total knee arthroplasty system indicated for patients with severe knee pain and disability due to: rheumatoid arthritis, osteoarthritis, traumatic arthritis, polyarthritis. collagen disorders, and/or avascular necrosis of the femoral condyle. post-traumatic loss of joint configuration, particularly when there is patellofemoral erosion, dysfunction or prior patellectomy. moderate valgus, varus, or flexion deformities. the salvage of previously failed surgical attempts or for a knee in which satisfactory stability in

NexGen? Complete Knee Solution Rotating Hinge Knee Tibial Component, Precoat  - Uncoated knee tibia prosthesis, metallic Austrálie - angličtina - Department of Health (Therapeutic Goods Administration)

nexgen? complete knee solution rotating hinge knee tibial component, precoat - uncoated knee tibia prosthesis, metallic

zimmer biomet pty ltd - 32832 - uncoated knee tibia prosthesis, metallic - modular tibial component of the nexgen rotating hinge knee prosthesis system intended for flexion/extension and internal/external rotation between the femoral and tibial components, but is constrained in the anterior/posterior and medial/lateral directions by means of a femoral hinge post extension. tibial components are made from zimaloy? cobalt-chromium-molybdenum alloyand are for cemented use only. tibial component of the nexgen rotating hinge knee prosthesis system intended to repair or replace the tibial knee joint, for patients with mderate to severe knee instability, significant bone loss and/or ligament deficiencies caused by neoplasms, trauma, rheumatoid arthritis, osteoarthritis, traumatic arthritis, polyarthritis, collagen disorders, and/or avascular necrosis of the femoral condyle, valgus, varus, or flexion deformities, the salvage of previously failed surgical attempts.

NexGen? Complete Knee Solution Rotating Hinge Knee (RHK), Femoral Component, Option   - Uncoated knee femur prosthesis Austrálie - angličtina - Department of Health (Therapeutic Goods Administration)

nexgen? complete knee solution rotating hinge knee (rhk), femoral component, option - uncoated knee femur prosthesis

zimmer biomet pty ltd - 32831 - uncoated knee femur prosthesis - femoral component of the nexgen rotating hinge knee prosthesis system intended for flexion/extension and internal/external rotation between the femoral and tibial components, but is constrained in the anterior/posterior and medial/lateral directions by means of a femoral hinge post extension. manufactured from zimaloy? cobalt-chromium-molybdenum alloy. for cemented use only. femoral component of the nexgen rotating hinge knee prosthesis system intended for patients with moderate to severe knee instability, significant bone loss and/or ligament deficiencies caused by neoplasms, trauma, rheumatoid arthritis, osteoarthritis, traumatic arthritis, polyarthritis, collagen disorders, and/or avascular necrosis of the femoral condyle, valgus, varus, or flexion deformities, the salvage of previously failed surgical attempts.

NexGen? Complete Knee Solution, Fluted Stemmed Tibial Component, Option  - Uncoated knee tibia prosthesis, metallic Austrálie - angličtina - Department of Health (Therapeutic Goods Administration)

nexgen? complete knee solution, fluted stemmed tibial component, option - uncoated knee tibia prosthesis, metallic

zimmer biomet pty ltd - 32832 - uncoated knee tibia prosthesis, metallic - fluted stemmed plate tibial component of the nexgen semiconstrained, nonlinked condylar knee system. it is designed to be cemented not only on the proximal surface of the tibal, but around the keel of the plate as well. it is made from tivanium ti-6al-4v alloy and is for cemented use. fluted stemmed plate tibial component of the nexgen semiconstrained, nonlinked condylar knee prosthesis system intended to repair or replace the tibial knee joint, for patients with severe knee pain and disability due to: rheumatoid arthritis, osteoarthritis, traumatic arthritis, polyarthritis. collagen disorders, and/or avascular necrosis of the femoral condyle, post-traumatic loss of joint configuration, particularly when there is patellofemoral erosion, dysfunction or prior patellectomy. moderate valgus, varus, or flexion deformities. the salvage of previously failed surgical attempts or for a knee in which satisfactory stability in flexion cannot be obtained at the time of surgery.

NexGen? Complete Knee Solution, Rotating Hinge Knee, Articular Surface (With Hinge Post Extension)  - Prosthesis, knee, internal, insert component Austrálie - angličtina - Department of Health (Therapeutic Goods Administration)

nexgen? complete knee solution, rotating hinge knee, articular surface (with hinge post extension) - prosthesis, knee, internal, insert component

zimmer biomet pty ltd - 46585 - prosthesis, knee, internal, insert component - articular surface component of the nexgen rotating hinge knee system intended for flexion/extension and internal/external rotation between the femoral and tibial components, but is constrained in the anterior/posterior and medial/lateral directions by means of a femoral hinge post extension. it is made from ultra-high molecular-weight polyethylene, and available in multiple thicknesses to facilitate soft tissue tensioning and joint line restoration. for cemented use only. articular surface component of the nexgen rotating hinge knee system indicated for patients with moderate to severe knee instability, significant bone loss and/or ligament deficiencies caused by neoplasms, trauma, rheumatoid arthritis, osteoarthritis, traumatic arthritis, polyarthritis, collagen disorders, and/or avascular necrosis of the femoral condyle, valgus, varus, or flexion deformities, or the salvage of previously failed surgical attempts.

NexGen? Complete Knee Solution CR-Flex Femoral Component, Porous w/Calcicoat? Ceramic Coating - Coated knee femur prosthesis Austrálie - angličtina - Department of Health (Therapeutic Goods Administration)

nexgen? complete knee solution cr-flex femoral component, porous w/calcicoat? ceramic coating - coated knee femur prosthesis

zimmer biomet pty ltd - 33745 - coated knee femur prosthesis - a cruciate ligament retaining (cr) porous femoral component coated with calcicoat? ceramic coating (hatcp). it is a femoral component of the nexgen semi constrained, non-linked condylar knee system for uncemented (biological fixation) use only and is made from zimaloy? cobalt-chromium-molybdenum alloy?. intended to repair or replace the femoral knee joint for patients with severe knee pain and disability due to: rheumatoid arthritis, osteoarthritis, traumatic arthritis, polyarthritis. collagen disorders, and/or avascular necrosis of the femoral condyle, post-traumatic loss of joint configuration, particularly when there is patellofemoral erosion, dysfunction or prior patellectomy. moderate valgus, varus, or flexion deformities. the salvage of previously failed surgical attempts or for a knee in which satisfactory stability in flexion cannot be obtained at the time of surgery.

NexGen? Complete Knee Solution Legacy? Constrained Condylar Knee (LCCK), Articular Surface w Locking Screw - Prosthesis, knee, internal, insert component Austrálie - angličtina - Department of Health (Therapeutic Goods Administration)

nexgen? complete knee solution legacy? constrained condylar knee (lcck), articular surface w locking screw - prosthesis, knee, internal, insert component

zimmer biomet pty ltd - 46585 - prosthesis, knee, internal, insert component - articular surface component of of the nexgen semiconstrained, nonlinked condylar knee system for use when both cruciate ligaments are excised and when greater varus/valgus constraint is required. available in multiple thicknesses to facilitate soft tissue tensioning and joint line restoration. it is made from ultra-high molecular weight polyethylene and indicated for cemented use. intended for patients with severe knee pain and disability due to rheumatoid arthritis,osteoarthritis, traumatic arthritis, polyarthritis, collagen disorders, and/or avascular necrosis of the femoral condyle post-traumatic loss of joint configuration, particularly when there is patellofemoral erosion, dysfunction or prior patellectomy, moderate valgus, varus, or flexion deformities, the salvage of previously failed surgical attempts or for a knee in which satisfactory stability in flexion cannot be obtained at the time of surgery.

NexGen? Complete Knee Solution Legacy? Constrained Condylar Knee (LCCK), Femoral Component, Option - Uncoated knee femur prosthesis Austrálie - angličtina - Department of Health (Therapeutic Goods Administration)

nexgen? complete knee solution legacy? constrained condylar knee (lcck), femoral component, option - uncoated knee femur prosthesis

zimmer biomet pty ltd - 32831 - uncoated knee femur prosthesis - femoral component of the nexgen semiconstrained, nonlinked condylar knee system with a non-coated fixation surface. for use when both cruciate ligaments are excised and when greater varus/valgus constraint is required. it is made from zimaloy? cobalt-chromium-molybdenum alloy and indicated for cemented use. intended for patients with severe knee pain and disability due to rheumatoid arthritis, osteoarthritis, traumatic arthritis, polyarthritis, collagen disorders, and/or avascular necrosis of the femoral condyle, post-traumatic loss of joint configuration, particularly when there is patellofemoral erosion, dysfunction or prior patellectomy, moderate valgus, varus, or flexion deformities, the salvage of previously failed surgical attempts or for a knee in which satisfactory stability in flexion cannot be obtained at the time of surgery.

NexGen? Complete Knee Solution Legacy? Knee PS LPS-Flex Femoral Component, Option w/ Ti-Nidium? Surface Hardening Process - Prosthesis, inter - Uncoated knee femur prosthesis Austrálie - angličtina - Department of Health (Therapeutic Goods Administration)

nexgen? complete knee solution legacy? knee ps lps-flex femoral component, option w/ ti-nidium? surface hardening process - prosthesis, inter - uncoated knee femur prosthesis

zimmer biomet pty ltd - 32831 - uncoated knee femur prosthesis - designed with an extended posterior condyle radius, providing greater tibio-femoral contact area in deep flexion. the increased contact area reduces the possibility of point loading as flexion approaches 155?. indicated for use with lps-flex prolong articular surfaces. manufactured from tivanium? ti-6al-4v alloy with a ti-nidium? surface hardening process. for cemented use only. the nexgen? cks legacy? knee lps-flex femoral component, option w/ ti-nidium? surface hardening process is indicated for patients with severe knee pain and disability due to: - rheumatoid arthritis, osteoarthritis, traumatic arthritis, polyarthritis - collagen disorders, and/or avascular necrosis of the femoral condyle - post-traumatic loss of joint configuration, particularly when there is patellofemoral erosion, dysfunction or prior patellectomy - moderate valgus, varus, or flexion deformities - the salvage of previously failed surgical attempts or for a knee in which satisfactory stability in flexion cannot be obtained at the time of surgery.

NexGen? Complete Knee Solution Cruciate Retaining(CR) Trabecular Metal? Monoblock Tibial Component - Prosthesis, knee, patello/femorotibial, constrained, cemented, polymer/metal/polymer Austrálie - angličtina - Department of Health (Therapeutic Goods Administration)

nexgen? complete knee solution cruciate retaining(cr) trabecular metal? monoblock tibial component - prosthesis, knee, patello/femorotibial, constrained, cemented, polymer/metal/polymer

zimmer biomet pty ltd - 33667 - trabeculated knee tibia/insert prosthesis - cruciate retaining (cr) tibial component designed for use with a functional cruciate ligament in conjunction with a cr or cra femoral component. cr tibias have a monoblock design where the polyethylene (uhmwpe) is directly molded into the tantalum (trabecular metal) base plate. the undersides of the monoblock tibias possess two hexagonal-shaped trabecular metal posts. it is available in multiple thickness options to facilitate soft tissue tensioning and joint line restoration. the nexgen? trabecular metal cr tibial component is intended for use where severe degeneration, trauma, or other pathology of the knee joint indicates cemented or cementless total knee arthroplasty.