GORE? EXCLUDER? lliac Branch Endoprosthesis, Internal Iliac Component - Abdominal aortic aneurysm stent Austrálie - angličtina - Department of Health (Therapeutic Goods Administration)

gore? excluder? lliac branch endoprosthesis, internal iliac component - abdominal aortic aneurysm stent

w l gore & associates (australia) pty ltd - 46777 - abdominal aortic aneurysm stent - the internal iliac component (iic) is a component of the gore? excluder? iliac branch endoprosthesis (ibe). the iic is loaded onto a delivery catheter and is used to extend into the internal iliac artery. the gore? excluder? internal iliac component is a component of the gore? excluder? iliac branch endoprosthesis (ibe). the gore? excluder? iliac branch endoprosthesis (ibe) is intended to isolate the common iliac artery from systemic blood flow and preserve blood flow in the external iliac and internal iliac arteries in patients with an iliac or aortoiliac aneurysm, who have appropriate anatomy, including: 1. adequate iliac / femoral access 2. minimum common iliac diameter of 17 mm at the proximal implantation zone of the ibe 3. external iliac artery treatment diameter range of 6.5 ?25 mm and seal zone length of at least 10 mm 4. internal iliac artery treatment diameter range of 6.5 ?13.5 mm and seal zone length of at least 10 mm

GORE? EXCLUDER? lliac Branch Endoprosthesis, Iliac Branch Component ? Abdominal aortic aneurysm stent Austrálie - angličtina - Department of Health (Therapeutic Goods Administration)

gore? excluder? lliac branch endoprosthesis, iliac branch component ? abdominal aortic aneurysm stent

w l gore & associates (australia) pty ltd - 46777 - abdominal aortic aneurysm stent - the iliac branch component is a component of the gore? excluder? lliac branch endoprosthesis (ibe). the ibc is a bifurcated iliac branch device with an external iliac leg and an internal iliac artery gate. the ibc is placed in the common iliac at a level that allows the gate of the ibc access to the internal iliac artery. it will treat external iliac artery diameters of 6.5? 13.5mm and is loaded onto a delivery catheter. the gore? excluder? iliac branch component is a component of the gore? excluder? iliac branch endoprosthesis (ibe) which is intended to isolate the common iliac artery from systemic blood flow and preserve blood flow in the external iliac and internal iliac arteries in patients with an iliac or aortoiliac aneurysm, who have appropriate anatomy, including: 1. adequate iliac / femoral access 2. minimum common iliac diameter of 17 mm at the proximal implantation zone of the ibe 3. external iliac artery treatment diameter range of 6.5 ? 25 mm and seal zone length of at least 10 mm 4. internal iliac artery treatment diameter range of 6.5 ? 13.5 mm and seal zone length of at least 10 mm

GORE? EXCLUDER? Conformable AAA Trunk-Ipsilateral Leg Endoprosthesis - Abdominal aortic aneurysm stent Austrálie - angličtina - Department of Health (Therapeutic Goods Administration)

gore? excluder? conformable aaa trunk-ipsilateral leg endoprosthesis - abdominal aortic aneurysm stent

w l gore & associates (australia) pty ltd - 46777 - abdominal aortic aneurysm stent - the gore? excluder? conformable aaa endoprosthesis is a single-use, permanently implanted device for the treatment of abdominal aortic aneurysm (aaa), an enlargement of the aorta caused by a weakening of the artery wall. the gore? excluder? conformable aaa endoprosthesis may be used to accommodate specific anatomy of an aneurysm. the gore? excluder? conformable aaa endoprosthesis is intended to exclude the aneurysm from the blood circulation in patients diagnosed with infrarenal abdominal aortic aneurysm (aaa) disease and who have appropriate anatomy as described below: ? adequate iliac / femoral access ? infrarenal aortic neck treatment diameter range of 16?32 mm ? a minimum aortic neck length of 10 mm when proximal aortic neck angulation is less than or equal to 60 degrees ? a minimum aortic neck length of 15 mm when proximal aortic neck angulation is less than or equal to 90 degrees ? iliac artery treatment diameter range of 8?25 mm and iliac distal vessel seal zone length of at least 10 mm

GORE? SYNECOR INTRAPERITONEAL BIOMATERIAL - Abdominal hernia surgical mesh, composite-polymer Austrálie - angličtina - Department of Health (Therapeutic Goods Administration)

gore? synecor intraperitoneal biomaterial - abdominal hernia surgical mesh, composite-polymer

w l gore & associates (australia) pty ltd - 44756 - abdominal hernia surgical mesh, composite-polymer - the biomaterial is a composite mesh comprised of a non-absorbable macroporous knit constructed of monofilament polytetrafluoroethylene (ptfe) fibers. the visceral surface is a bioabsorbable synthetic nonporous film comprised of poly (glycolide:trimethylene carbonate) copolymer (pga:tmc). the parietal surface is a bioabsorbable synthetic porous fibrous structure comprised of pga:tmc copolymer. gore? synecor intraperitoneal biomaterial is designed for intraperitoneal placement. the gore? synecor intraperitoneal biomaterial device is intended for use as a non-absorbable reinforcing or bridging material with placement between parietal and visceral tissue.

Gore-Tex Cardiovascular Patch - Cardiovascular patch, synthetic Austrálie - angličtina - Department of Health (Therapeutic Goods Administration)

gore-tex cardiovascular patch - cardiovascular patch, synthetic

w l gore & associates (australia) pty ltd - 31744 - cardiovascular patch, synthetic - the device is a durable, easy to handle, synthetic patch designed for optimal tissue ingrowth while minimizing aneurysmal dilation in a wide variety of cardiovascular applications. constructed from multidirectional strength eptfe, the patch is designed to resist aneurysmal dilation and optimize tissue ingrowth. the gore tex cardiovascular patch is intended for use in carotid artery and congenital heart defect patching.

GORE? CARDIOFORM ASD Occluder - Cardiac occluder Austrálie - angličtina - Department of Health (Therapeutic Goods Administration)

gore? cardioform asd occluder - cardiac occluder

w l gore & associates (australia) pty ltd - 45418 - cardiac occluder - the gore? cardioform asd occluder (system) consists of an implantable occluder and a delivery system. the occluder is comprised of a platinum-filled nickel-titanium (nitinol) wire frame covered with expanded polytetrafluoroethylene (eptfe). the eptfe includes a hydrophilic surface treatment to facilitate echocardiographic imaging of the occluder and surrounding tissue during implantation. the gore? cardioform asd occluder is a permanently implanted medical device intended to close an ostium secundum atrial septal defect (asd).

GORE VIABAHN VBX Balloon Expandable Endoprosthesis -Peripheral artery endovascular stent-graft, drug-coated Austrálie - angličtina - Department of Health (Therapeutic Goods Administration)

gore viabahn vbx balloon expandable endoprosthesis -peripheral artery endovascular stent-graft, drug-coated

w l gore & associates (australia) pty ltd - 66619 - peripheral artery endovascular stent-graft, drug-coated - a balloon-expandable, endoluminal endoprosthesis consisting of a 316l surgical grade stainless steel stent and an eptfe and fep graft. its surface is coated with an immobilized heparin surface (cbas? heparin surface) which consists of cbas? covalently attached to a polymeric base matrix consisting of polyethyleneimine (cbas?-polymin) and dextran sulphate. the stent is pre-mounted on a delivery system equipped with a semi-compliant balloon. the gore? viabahn? vbx balloon expandable endoprosthesis is indicated for the treatment of de novo or restenotic lesions found in iliac arteries with reference vessel diameters ranging from 5 mm - 13 mm and lesion lengths up to 110 mm, including lesions at the aortic bifurcation.

Gore Cardioform Septal Occluder - Cardiac Occluder Austrálie - angličtina - Department of Health (Therapeutic Goods Administration)

gore cardioform septal occluder - cardiac occluder

w l gore & associates (australia) pty ltd - 45418 - cardiac occluder - a platinum-filled nickel-titanium wire frame covered with hydrophilic coated eptfe and a catheter delivery system. when fully deployed, the occluder assumes a left and right atrial disc configuration to bridge septal defects. the gore cardioform septal occluder is a permanently implanted prosthesis indicated for the percutaneous, transcatheter closure of atrial septal defects (asds), such as ostium secundrum and patent foramen ovale (pfos).

GORE? EXCLUDER? Conformable AAA Aortic Extender Endoprosthesis - Abdominal aortic aneurysm stent Austrálie - angličtina - Department of Health (Therapeutic Goods Administration)

gore? excluder? conformable aaa aortic extender endoprosthesis - abdominal aortic aneurysm stent

w l gore & associates (australia) pty ltd - 46777 - abdominal aortic aneurysm stent - the conformable aortic extender component (excc ae) is intended to provide proximal extension to the conformable trunk-ipsilateral leg component if additional seal is needed to facilitate exclusion of the aaa from blood flow. the excc ae has individual stent rings as body rows, similar to the excc trunk-ipsilateral leg device. the aortic extender endoprostheses are intended to be used after deployment of the gore? excluder? conformable aaa endoprosthesis. these extensions are intended to be used when additional length and / or sealing for aneurysmal exclusion is desired.

Gore BIO-A Tissue Reinforcement - Mesh, polymeric, biodegradable Austrálie - angličtina - Department of Health (Therapeutic Goods Administration)

gore bio-a tissue reinforcement - mesh, polymeric, biodegradable

w l gore & associates (australia) pty ltd - 44688 - mesh, polymeric, biodegradable - rectangular sheets of porous, fibrous mesh. the instructions for use indicate that this device is a tailorable, synthetic, bioabsorbable material intended to be a temporary bridge of defects until the bioabsorbable nature of the device allows the body to fill the defect with native tissue. in repairs requiring high strength, a permanent overlay patch is strongly recommended. the gore bio-a tissue reinforcement is intended for use in the reinforcement of soft tissue.