País: Regne Unit
Idioma: anglès
Font: DrWeigert
Dr. Weigert
Date revised: 02.02.2016 Print date: 02.02.16 2 / GB- 800882-001-02 Version: 2 / GB Replaces Version: 1 / GB SAFETY DATA SHEET IN ACCORDANCE WITH REGULATION (EC) NO 1907/2006 NEODISHER SEPTO 3000 Page 1(12) SECTION 1: IDENTIFICATION OF THE SUBSTANCE/MIXTURE AND OF THE COMPANY/UNDERTAKING 1.1. PRODUCT IDENTIFIER neodisher Septo 3000 1.2. RELEVANT IDENTIFIED USES OF THE SUBSTANCE OR MIXTURE AND USES ADVISED AGAINST USE OF THE SUBSTANCE/PREPARATION disinfectants 1.3. DETAILS OF THE SUPPLIER OF THE SAFETY DATA SHEET ADDRESS: Chemische Fabrik Dr. Weigert GmbH & Co. KG Mühlenhagen 85 D-20539 Hamburg Telephone no. +49 40 789 60 0 Fax no. +49 40 789 60 120 www.drweigert.com E-MAIL ADDRESS OF PERSON RESPONSIBLE FOR THIS SDS: sida@drweigert.de 1.4. EMERGENCY TELEPHONE NUMBER GBK/ Infotrac: (USA domestic) 1 800 535 5053 or international +1 352 323 3500 SECTION 2: HAZARDS IDENTIFICATION 2.1. CLASSIFICATION OF THE SUBSTANCE OR MIXTURE CLASSIFICATION (REGULATION (EC) NO. 1272/2008) Classification (Regulation (EC) No. 1272/2008) Acute Tox. 4 H302 Acute Tox. 4 H332 Skin Corr. 1A H314 Eye Dam. 1 H318 Skin Sens. 1 H317 Resp. Sens. 1 H334 STOT SE 3 H335 Muta. 2 H341 Carc. 1B H350 2.2. LABEL ELEMENTS LABELLING ACCORDING TO REGULATION (EC) NO 1272/2008 HAZARD PICTOGRAMS SIGNAL WORD Danger HAZARD STATEMENTS H302+H332 Harmful if swallowed or if inhaled. Date revised: 02.02.2016 Print date: 02.02.16 2 / GB- 800882-001-02 Version: 2 / GB Replaces Version: 1 / GB SAFETY DATA SHEET IN ACCORDANCE WITH REGULATION (EC) NO 1907/2006 NEODISHER SEPTO 3000 Page 2(12) H314 Causes severe skin burns and eye damage. H317 May cause an allergic skin reaction. H334 May cause allergy or asthma symptoms or breathing difficulties if inhaled. H335 May cause respiratory irritation. H341 Suspected of causing genetic defects. H350 May cause cancer. PRECAUTIONARY STATEMENTS P201 Obtain special instructions before use. P260 Do not breathe dust/fume/gas/mist/vapours/spray. P280 Wear protective gloves/protective clothing/eye protection/face protection. P303+P361+ Llegiu el document complet
WWW.DRWEIGERT.COM neodisher ® Septo 3000 With the above information, to our current knowledge we describe our product regarding safety necessities, but we do not involve any quality description or promise certain properties. Chemische Fabrik Dr. Weigert GmbH & Co. KG Tel.: +49-40-7 89 60-0 info@drweigert. de Mühlenhagen 85 • D-20539 Hamburg Fax: +49-40-7 89 60-120 www. drweigert. de Disinfectant for the manual reprocessing of thermostable and thermolabile instruments Liquid concentrate Fields of application: • Disinfection of thermostable and thermolabile medical devices in immersion or ultrasonic baths • Also suitable for the disinfection of flexible endoscopes Performance spectrum: • Bactericidal, fungicidal, mycobactericidal, virucidal and sporicidal activity. Confirmed by certification • Suitable for all standard materials such as stainless steel, chrome-nickel steel, plastics, rubber, porcelain and glass • For manual pre-cleaning the use of neodisher MediClean forte is recommended Special properties: • Wide range of activity, even with short action times • Excellent material compatibility • VAH 1 -listed , on the list of the IHO 2 for disinfectants with virucidal activity Application and dosage: neodisher Septo 3000 is used in immersion and ultrasonic baths. Depending on the desired activity the working solution must be prepared according to the below mentioned dosing recommendations. The working solution must always be prepared with cold water (at room temperature). Clean the instruments resp. endoscopes thoroughly, e.g. with the detergent neodisher MediClean forte prior to disinfection. Then place the instruments resp. endoscopes into the neodisher Septo 3000 working solution and adhere to the below mentioned contact times. Never exceed the limit for the exposure time in ultrasonic baths which is recommended by the instrument manufacturer. For correct disinfection in ultrasonic baths the contact times must be observed. Open and dismantle the instruments as far as possible. Ensure that a Llegiu el document complet