Logical G-Series Cup Shell - Acetabular shell অস্ট্রেলিয়া - ইংরেজি - Department of Health (Therapeutic Goods Administration)

logical g-series cup shell - acetabular shell

signature orthopaedics pty ltd - 43167 - acetabular shell - the logical g-series cup shell is implanted in the patient's acetabulum and houses a liner to replace the patient's natural acetabulum as part of a total hip joint replacement. the device is porous coated with ti to provide a surface for bone ingrowth. the device is manufactured from ti6al4v alloy. the device is intended for cementless use only. the logical g-series cup shell is intended to connect a liner to the patient's acetabulum as part of a total hip joint replacement, where bone stock is sufficient to support the implant. when a surgeon has selected prosthetic replacement as the preferred treatment, the devices are indicated for: ?non-inflammatory degenerative joint disease including osteoarthritis or avascular necrosis ?inflammatory joint disease including rheumatoid arthritis (excluding tsi stem) ?correction of functional deformity including congenital hip dysplasia ?traumatic injury involving the hip joint including traumatic arthritis or femoral head or neck fracture ?failed previous hip surgery including internal fixation or joint fusion, reconstruction, hemiarthroplasty, surface replacement, or total replacement

seleXys PC shell uncemented - Acetabular shell অস্ট্রেলিয়া - ইংরেজি - Department of Health (Therapeutic Goods Administration)

selexys pc shell uncemented - acetabular shell

mathys orthopaedics pty ltd - 43167 - acetabular shell - the selexys pc uncemented shell is an acetabular shell. the flattened pole area of the cup ensures load transmission near the rim of the cup. the 2mm oversizing of the cup equator enables optimum primary fixation of the implant in the acetabulum. the pure titanium pellets are sintered onto the titanium shell, creating a porous surface for osteointegration. the selexys hip system shell pc is an uncemented acetabular shell that forms part of the selexys hip system that is designed for treating diseased hip joints for primary and revision surgery.

M2A Magnum Hip System acetabular shell Tri-spike  - Acetabular shell অস্ট্রেলিয়া - ইংরেজি - Department of Health (Therapeutic Goods Administration)

m2a magnum hip system acetabular shell tri-spike - acetabular shell

zimmer biomet pty ltd - 43167 - acetabular shell - cobalt chrome alloy acetabular shell for uncemented use. to be used with active articulation dual mobility system only. fully hemispheric m2a magnum tri-spike cup features clinically proven ti alloy pps coating for fixation. incorporates 3 spikes; two to be placed superior in ilium and one spike to be placed inferiorly near pubic ramus. the biomet m2a-magnum tri-spike acetabular shells are intended for use in non-cemented primary and revision hip joint replacement procedures, in combination with the active articulation hip bearings system. indications: non-inflammatory degenerative joint disease including osteoarthritis and avascular necrosis; rheumatoid arthritis; correction of functional deformity; treatment of non-union, femoral neck fracture, and trochanteric fractures of the proximal femur with head involvement, unmanageable using other techniques; revision procedures where other treatment or devices have failed. the components of the biomet m2a-magnum tri-spike acetabular shells are also cleared for dia

Trilogy? IT Acetabular System Shell, Porous, with Calcicoat? Ceramic Coating - Acetabular shell অস্ট্রেলিয়া - ইংরেজি - Department of Health (Therapeutic Goods Administration)

trilogy? it acetabular system shell, porous, with calcicoat? ceramic coating - acetabular shell

zimmer biomet pty ltd - 43167 - acetabular shell - trilogy it shell is a part of the trilogy? it acetabular system. available with multi or cluster screw holes to provide additional fixation and security in cases where acetabular bone stock is deficient. made from tivanium? ti-6al-4v alloy with commercially pure titanium fiber metal metallurgically bonded to shell exterior. calcicoat is plasma sprayed onto porous fiber metal surfaces for implant stability by allowing biological fixation of bone to the implant. used with or without bone cement. the trilogy it acetabular shell is indicated for primary or revision surgery in skeletally mature individuals for rehabilitating hips damaged as a result of noninflammatory degenerative joint disease (nidjd) or its composite diagnoses of osteoarthritis, avascular necrosis, protrusio acetabuli, traumatic arthritis, slipped capital epiphysis, fused hip, fracture of the pelvis, and diastrophic variant.

Acetabular shell অস্ট্রেলিয়া - ইংরেজি - Department of Health (Therapeutic Goods Administration)

acetabular shell

smith & nephew pty ltd - 43167 - acetabular shell - the reflection cemented acetabular component is an acetabular shell component of the reflection acetabular system intended to be used with bone cement. hip components are indicated for individuals undergoing primary and revision surgery where other treatments or devices have failed in rehabilitating hips damaged as a result of trauma or noninflammatory degenerative joint disease (nidjd) or any of its composite diagnoses of osteoarthritis, avascular necrosis, traumatic arthritis, slipped capital epiphysis, fused hip, fracture of the pelvis, and diastrophic variant. hip components are also indicated for inflammatory degenerative joint disease including rheumatoid arthritis, arthritis secondary to a variety of diseases and anomalies, and congenital dysplasia; treatments of nonunion, femoral neck fracture, and trochanteric fractures of the proximal femur with head involvement that are unmanageable using other techniques; endoprosthesis, femoral osteotomy, or girdlestone resection; fracture-dislocation of the hip; and correction of deformity.

Exceed ABT Multi-Hole Ringloc-X Acetabular Shell PC + HA - Acetabulum prosthesis - Acetabular shell অস্ট্রেলিয়া - ইংরেজি - Department of Health (Therapeutic Goods Administration)

exceed abt multi-hole ringloc-x acetabular shell pc + ha - acetabulum prosthesis - acetabular shell

zimmer biomet pty ltd - 43167 - acetabular shell - exceed abt acetabular shell component hip joint replacement prosthesis. made from titanium alloy with porous and hydroxyapatite coating. for cementless applications. for use with biomet e1 bearings utilizing the ringloc-x liner retaining mechanism. multi hole shells are not supplied with titanium-blanking plugs. exceed abt abt multi-hole ringloc-x acetabular shells pc + ha are used in conjunction with other hip prosthesis components to form part of a total hip joint replacement system. the indications for the use include: 1. non-inflammatory degenerative joint diseases including osteoarthritis, avascular necrosis and post-traumatic arthritis. 2. rheumatoid arthritis. 3. correction of functional deformity. 4. revision of failed joint reconstruction or treatment. 5. treatment of femoral neck and trochanteric fractures of the proximal femur with femoral head involvement and which are unmanageable using other techniques

POLARCUP Shell Ti-Plasma - Acetabular shell অস্ট্রেলিয়া - ইংরেজি - Department of Health (Therapeutic Goods Administration)

polarcup shell ti-plasma - acetabular shell

smith & nephew pty ltd - 43167 - acetabular shell - a sterile, stainless steel (m30nw) titanium (cp ti) plasma coated acetabular shell with a high degree of surface roughness to assist in osseointegration. the outside dome of the acetabular shell has a circular feature to ensure correct cup placement and optimal load transfer and the equatorial teeth and ribs prevent rotation and allow for good primary stability. the internal surface of the acetabular shell is highly polished allowing for minimal wear. the acetabular shell is impacted into place. polarcup is indicated for advanced degeneration of the hip joint as a result of osteoarthritis, avascular necrosis, posttraumatic arthritis, or rheumatoid arthritis ? femoral neck fracture or proximal fracture of the hip joint ? conditions resulting from previous operations of the hip joint, such as failed total hip prosthesis

Acetabular shell অস্ট্রেলিয়া - ইংরেজি - Department of Health (Therapeutic Goods Administration)

acetabular shell

zimmer biomet pty ltd - 43167 - acetabular shell - metal device located in periphery of acetabular shell to assist with locking the polyethylene acetabular liner in place. device is packaged separately as a spare.

R3 Hemispherical Acetabular Shell - Acetabular shell অস্ট্রেলিয়া - ইংরেজি - Department of Health (Therapeutic Goods Administration)

r3 hemispherical acetabular shell - acetabular shell

smith & nephew pty ltd - 43167 - acetabular shell - a sterile shell of a two-piece cementless acetabulum prosthesis to be used with a liner which serves as the articulating surface. the outer surface of the titanium alloy (ti-6al-4v) acetabular shell has a titanium porous coating to provide enhanced scratch-fit against cancellous and cortical bone. the shell is inserted into a prepared acetabulum with a shell inserter, impacted into place, and has the option of holes for additional screw fixation if required. hip components are indicated for individuals undergoing primary and revision surgery where other treatments or devices have failed in rehabilitating hips damaged as a result of degenerative joint disease or any of its composite diagnoses of osteoarthritis, avascular necrosis, and traumatic arthritis. hip components are also indicated for inflammatory degenerative joint disease including rheumatoid arthritis, congenital dysplasia, femoral neck fracture, and trochanteric fractures of the proximal femur with head involvement that are unmanageable using other techniques, and fracture-dislocation of the hip.

Pinnacle Acetabular Shells with Gription - Acetabular Shell অস্ট্রেলিয়া - ইংরেজি - Department of Health (Therapeutic Goods Administration)

pinnacle acetabular shells with gription - acetabular shell

johnson & johnson medical pty ltd t/a depuy synthes - 43167 - acetabular shell - the pinnacle acetabular shells with gription are titanium shells coated in gription (titanium sintered particles on a titanium sintered beads substrate) to enable cementless, biological fixation into the prepared acetabulum. additionally, the pinnacle acetabular shells with gription are available with of a range of holes to allow screws. an appropriate liner is then placed into the implanted shell. the pinnacle acetabular shell with gription is the acetabular shell component used during primary or revision total hip arthoplasty and is intended to provide increased patient mobility and reduce pain by replacing the damaged hip joint articulation in patients where there is evidence of sufficient sound bone to seat and support the components. total hip replacement is indicated in the following conditions: 1. a severely painful and/or disabled joint from osteoarthritis, traumatic arthritis, rheumatoid arthritis, or congenital hip dysplasia. 2. avascular necrosis of the femoral head. 3. acute traumatic fracture of the femoral head or neck. 4. failed previous hip surgery including joint reconstruction, internal fixation, arthrodesis, hemiarthroplasty, surface replacement arthroplasty, or total hip replacement. 5. certain cases of ankylosis.