HD-1A Liquid Concentrate (Acid) For Bicarbonate Haemodialysis & Haemodiafiltration

Страна: Малайзия

Език: английски

Източник: NPRA (National Pharmaceutical Regulatory Agency, Bahagian Regulatori Farmasi Negara)

Купи го сега

Активна съставка:

POTASSIUM CHLORIDE; SODIUM CHLORIDE (SALT); Calcium chloride; Magnesium Chloride; GLACIAL ACETIC ACID

Предлага се от:

B.BRAUN MEDICAL INDUSTRIES SDN BHD

INN (Международно Name):

POTASSIUM CHLORIDE; SODIUM CHLORIDE (SALT); Calcium chloride; Magnesium Chloride; GLACIAL ACETIC ACID

Броя в опаковка:

5000ml mL; 10000ml mL

Произведено от:

B.BRAUN MEDICAL INDUSTRIES SDN BHD

Данни за продукта

                                User Information
HD-1A LIQUID CONCENTRATE (ACID)
HD-1A LIQUID CONCENTRATE (ACID)
HD-1A LIQUID CONCENTRATE (ACID)
HD-1A LIQUID CONCENTRATE (ACID)
HD-1A LIQUID CONCENTRATE (ACID)
COMPOSITION
COMPOSITION
COMPOSITION
COMPOSITION
COMPOSITION
Each litre of concentrate contains:
Sodium Chloride
161.0 g
Potassium Chloride
5.5 g
Calcium Choride.2H
2
O
9.7 g
Magnesium Chloride.6H
2
0
3.7 g
Glacial Acetic Acid
8.8 g
Purified Water to
1000 ml
DESCRIPTION
DESCRIPTION
DESCRIPTION
DESCRIPTION
DESCRIPTION
A clear and colourless solution.
COMPOSITION OF THE READY-FOR-USE BICARBONATE HAEMODIALYSIS SOLUTION
COMPOSITION OF THE READY-FOR-USE BICARBONATE HAEMODIALYSIS SOLUTION
COMPOSITION OF THE READY-FOR-USE BICARBONATE HAEMODIALYSIS SOLUTION
COMPOSITION OF THE READY-FOR-USE BICARBONATE HAEMODIALYSIS SOLUTION
COMPOSITION OF THE READY-FOR-USE BICARBONATE HAEMODIALYSIS SOLUTION
1 L HD-1A (acid concentrate) + 34 L water of suitable quality + 1.83 L
of HD-1B (bicarbonate concentrate) yield
a ready-for-use bicarbonate haemodialysis solution with the following
electrolyte concentrations:
ELECTROLYTES
ELECTROLYTES
ELECTROLYTES
ELECTROLYTES
ELECTROLYTES
MMOL/L
MMOL/L
MMOL/L
MMOL/L
MMOL/L
Na
+
140.0
K
+
2.0
Ca
2+
1.8
Mg
2+
0.5
CI
-
107.6
CH
3
COO
-
4.0
HC0
3
-
35.0
The theoretical osmolarity of the ready-for-use bicarbonate
haemodialysis solution is 290.9 mOsm/L.
Freshly distilled water obtained under sterile conditions should be
used for diluting bicarbonate haemodialysis
concentrates.
Purified water may, however, also be used if it meets the
microbiological requirements of drinking water and
complies with the recommendations given below. If the water is
demineralized, watch out for pyrogens.
If purified water is used, particularly in the case of repeated
haemodialysis, it is necessary to be aware of the
possible presence of trace amounts of residues from water processing
or of chemical elements.
In particular, it is recommendable to monitor the amounts of
aluminium, tin , mercury, zinc, fluorides, phosphates
and sulphates in the water to be
                                