RINGER'S INJ LIQUID

国家: 加拿大

语言: 英文

来源: Health Canada

现在购买

产品特点 产品特点 (SPC)
21-11-2014

有效成分:

SODIUM CHLORIDE; CALCIUM CHLORIDE; POTASSIUM CHLORIDE

可用日期:

BAXTER CORPORATION

ATC代码:

B05BB01

INN(国际名称):

ELECTROLYTES

剂量:

860MG; 33MG; 30MG

药物剂型:

LIQUID

组成:

SODIUM CHLORIDE 860MG; CALCIUM CHLORIDE 33MG; POTASSIUM CHLORIDE 30MG

给药途径:

INTRAVENOUS

每包单位数:

1000ML

处方类型:

Ethical

治疗领域:

REPLACEMENT PREPARATIONS

產品總結:

Active ingredient group (AIG) number: 0300137001; AHFS:

授权状态:

CANCELLED POST MARKET

授权日期:

2016-07-15

产品特点

                                Page 1 of 5
PRESCRIBING INFORMATION
RINGER’S INJECTION, USP
IN VIAFLEX PLASTIC CONTAINER
Parenteral Replenisher
Baxter Corporation
Mississauga, Ontario L5N 0C2
Canada
Date of Revision:
November 17, 2014
Submission Control No: 177995
Baxter and Viaflex are Trademarks of Baxter International Inc.
Page 2 of 5
RINGER’S INJECTION, USP
IN VIAFLEX PLASTIC CONTAINER
SUMMARY PRODUCT INFORMATION
Ringer’s Injection, USP is a sterile, nonpyrogenic solution and
contains no bacteriostatic or antimicrobial agents or added buffers.
The composition, osmolarity and approx. pH of Ringer’s Injection,
USP is shown in Table 1.
Table 1
DIN
Size (mL)
Composition (g/L)
Osmolarity
(mOsmol/L)
pH
Ionic Concentration (mmol/L)
Caloric Content
(kcal/L)
Sodium
Chloride, USP
Calcium
Chloride
Dihydrate,
USP
Potassium
Chloride, USP
Sodium
Potassium
Calcium
Chloride
Ringer’s
Injection,
USP
00060925
1000
8.60
0.33
0.30
310
5.0 – 7.5
147
4
2.24
156
0
The Viaflex plastic container is fabricated from a specially
formulated polyvinyl chloride (PL 146 Plastic).
The amount of water that can permeate from inside the container into
the overwrap is insufficient to affect the solution
significantly. Solutions in contact with the plastic container can
leach out certain of its chemical components in very small
amounts within the expiration period, e.g. di-2-ethylhexyl phthalate
(DEHP), up to 5 parts per million. However, the safety of the
plastic has been confirmed in tests in animals according to USP
biological tests for plastic containers as well as by tissue culture
toxicity studies.
Normal physiologic isotonicity range is approximately 280-310
mOsmol/L. Administration of substantially hypotonic solutions
may cause hemolysis and administration of substantially hypertonic
solutions may cause vein damage.
ACTIONS
Ringer’s Injection, USP is a source of water for hydration and
provides electrolytes. It is capable of inducing diuresis depending
on the clinical conditions of the patient.
Solutions which are polyelectrolytic have value in maintaining 
                                
                                阅读完整的文件
                                
                            

其他语言的文件

产品特点 产品特点 法文 04-12-2014