neomoscan® CP plus 540

Kraj: Wielka Brytania

Język: angielski

Źródło: DrWeigert

Kup teraz

Ulotka dla pacjenta Ulotka dla pacjenta (PIL)
22-09-2017

Dostępny od:

Dr. Weigert

Ulotka dla pacjenta

                                Date revised: 11.01.2017
Print date: 26.05.17
3 / GB- 800185-012-01
Version: 3 / GB
Replaces Version: 2 /
GB
SAFETY DATA SHEET IN ACCORDANCE WITH REGULATION (EC) NO
1907/2006 NEOMOSCAN CP PLUS 540
Page 1(10)
SECTION 1: IDENTIFICATION OF THE SUBSTANCE/MIXTURE AND OF THE
COMPANY/UNDERTAKING
1.1. PRODUCT IDENTIFIER
neomoscan CP plus 540
1.2. RELEVANT IDENTIFIED USES OF THE SUBSTANCE OR MIXTURE AND USES
ADVISED AGAINST
USE OF THE SUBSTANCE/PREPARATION
Washing and cleaning products (including solvent based products)
1.3. DETAILS OF THE SUPPLIER OF THE SAFETY DATA SHEET
ADDRESS:
Chemische Fabrik Dr. Weigert GmbH & Co. KG
Mühlenhagen 85
D-20539 Hamburg
Telephone no.
+49 40 789 60 0
Fax no.
+49 40 789 60 120
www.drweigert.com
E-MAIL ADDRESS OF PERSON RESPONSIBLE FOR THIS SDS:
sida@drweigert.de
1.4. EMERGENCY TELEPHONE NUMBER
GBK/ Infotrac: (USA domestic) 1 800 535 5053 or international +1 352
323 3500
SECTION 2: HAZARDS IDENTIFICATION
2.1. CLASSIFICATION OF THE SUBSTANCE OR MIXTURE
CLASSIFICATION (REGULATION (EC) NO. 1272/2008)
Classification (Regulation (EC) No. 1272/2008)
Flam. Liq. 2
H225
Eye Irrit. 2
H319
STOT SE 3
H336
2.2. LABEL ELEMENTS
LABELLING ACCORDING TO REGULATION (EC) NO 1272/2008
HAZARD PICTOGRAMS
SIGNAL WORD
Danger
HAZARD STATEMENTS
H225
Highly flammable liquid and vapour.
H319
Causes serious eye irritation.
H336
May cause drowsiness or dizziness.
PRECAUTIONARY STATEMENTS
P210
Keep away from heat, hot surfaces, sparks, open flames and other
ignition
sources. No smoking.
Date revised: 11.01.2017
Print date: 26.05.17
3 / GB- 800185-012-01
Version: 3 / GB
Replaces Version: 2 /
GB
SAFETY DATA SHEET IN ACCORDANCE WITH REGULATION (EC) NO
1907/2006 NEOMOSCAN CP PLUS 540
Page 2(10)
P261
Avoid breathing dust/fume/gas/mist/vapours/spray.
P280
Wear protective gloves/protective clothing/eye protection/face
protection.
P305+P351+P338
IF IN EYES: Rinse cautiously with water for several minutes. Remove
contact
lenses, if present and easy to do. Continue rinsing.
P337+P313
If eye irritation persists: Get medical advice/
                                
                                Przeczytaj cały dokument
                                
                            

Charakterystyka produktu

                                NEOMOSCAN
® CP PLUS 540
Additive for the pharmaceutical and cosmetics industry – liquid
concentrate
Chemische Fabrik Dr. Weigert GmbH & Co. KG
Telefon: (040) 789 60 - 0
E-Mail: info@drweigert.de
Mühlenhagen 85, D – 20539 Hamburg
Telefax: (040) 789 60 - 120
Internet: www.drweigert.de
Die Angaben dieses Merkblattes beruhen auf unseren derzeitigen
Kenntnissen und Erfahrungen. Sie befreien den
Verwender nicht von eigenen Prüfungen und Versuchen. Eine rechtlich
verbindliche Zusicherung bestimmter
Eigenschaften kann hieraus nicht abgeleitet werden.
With the above information, which is appropriate to our current
knowledge we describe
our product regarding possible safety necessities, but we do not
involve any quality description
or promise certain properties.
Fields of application:
De-foaming and enhancing the cleaning performance of alkaline
solutions for cleaning
production plants and filling stations via automated CIP processes or
circulation processes
as well as for cleaning small and detachable parts in cleaning
systems.
For professional use only.
Characteristics:
neomoscan CP plus 540 is a de-foamer and cleaning enhancer based on
surfactants and
has the following properties:
•
de-foaming action at temperatures above 40 °C
•
supports cleaning due to emulsifying and dispersing action
•
especially effective also in systems heavily soiled with protein, fat
and oil
•
silicone-free
•
suitable for stainless steel (1.4301, 1.4571), chemical-compatible
synthetic
materials (PVC, PP) and seals (EPDM, PTFE)
•
material compatibility also depends on the alkaline basic components
used
Dosage:
neomoscan CP plus 540 is used in combination with solutions of soda
lye or assembled
alkaline detergents of the neomoscan CP alka range.
neomoscan CP plus 540 is added in concentrations of 0.05 - 1 weight%
to the alkaline
solution. The application temperature is 40 – 80 °C.
The exact application parameters are to be checked in practical tests.
The neomoscan CP plus 540 solution has to be rinsed off completely
(prefera
                                
                                Przeczytaj cały dokument
                                
                            

Dokumenty w innych językach

Ulotka dla pacjenta Ulotka dla pacjenta niemiecki 22-09-2017
Charakterystyka produktu Charakterystyka produktu niemiecki 22-09-2017
Ulotka dla pacjenta Ulotka dla pacjenta francuski 22-09-2017
Charakterystyka produktu Charakterystyka produktu francuski 22-09-2017
Ulotka dla pacjenta Ulotka dla pacjenta włoski 08-09-2017
Ulotka dla pacjenta Ulotka dla pacjenta niderlandzki 22-09-2017
Ulotka dla pacjenta Ulotka dla pacjenta polski 22-09-2017
Charakterystyka produktu Charakterystyka produktu polski 22-09-2017

Wyszukaj powiadomienia związane z tym produktem