Technescan PYP 20 mg kit for radiopharmaceutical preparation Ireland - English - HPRA (Health Products Regulatory Authority)

technescan pyp 20 mg kit for radiopharmaceutical preparation

curium netherlands b.v. - sodium pyrophosphate decahydrate - kit for radiopharmaceutical preparation - 20 milligram(s) - technetium (99mtc) compounds; technetium (99mtc) stannous agent labelled cells

TechneScan PYP 20 mg kit for radiopharm. prep. i.v. vial Belgium - English - AFMPS (Agence Fédérale des Médicaments et des Produits de Santé)

technescan pyp 20 mg kit for radiopharm. prep. i.v. vial

curium belgium s.p.r.l.-b.v.b.a. - sodium pyrophosphate 20 mg - kit for radiopharmaceutical preparation - 20 mg - sodium pyrophosphate decahydrate 20 mg - technetium (99mtc) stannous agent labelled cells

TECHNESCAN PYP KIT FOR RADIOPHARMACEUTICAL PREPARATION 20MGVIAL Singapore - English - HSA (Health Sciences Authority)

technescan pyp kit for radiopharmaceutical preparation 20mgvial

qt instruments (s) pte ltd - sodium pyrophosphate decahydrate - injection, powder, for solution - sodium pyrophosphate decahydrate 20mg/vial

TECHNESCAN PYP- technetium tc 99m pyrophosphate injection, powder, lyophilized, for solution United States - English - NLM (National Library of Medicine)

technescan pyp- technetium tc 99m pyrophosphate injection, powder, lyophilized, for solution

curium us llc - sodium pyrophosphate (unii: o352864b8z) (pyrophosphoric acid - unii:4e862e7grq), stannous chloride (unii: 1bqv3749l5) (stannous cation - unii:qi30938bms) - sodium pyrophosphate 11.9 mg in 10 ml - technetium tc 99m pyrophosphate injection is a skeletal imaging agent used to demonstrate areas of altered osteogenesis, and a cardiac imaging agent used as an adjunct in the diagnosis of acute myocardial infarction. as an adjunct in the diagnosis of confirmed myocardial infarction (ecg and serum enzymes positive), the incidence of false negative images has been found to be 6%. false negative images can also occur if made too early in the evolutionary phase of the infarct or too late in the resolution phase. in a limited study involving 22 patients in whom the ecg was positive and serum enzymes questionable or negative, but in whom the final diagnosis of acute myocardial infarction was made, the incidence of false negative images was 23%. the incidence of false positive images has been found to be 7 to 9%. false positive images have been reported following coronary by-pass graft surgery, in unstable angina pectoris, old myocardial infarcts and in cardiac contusions. technescan pyp is a blood pool imaging agen

Technescan PYP kit for radiopharmaceutical preparation United Kingdom - English - MHRA (Medicines & Healthcare Products Regulatory Agency)

technescan pyp kit for radiopharmaceutical preparation

curium pharma uk ltd - sodium pyrophosphate decahydrate - kit for radiopharmaceutical preparation - 20mg

TechneScan PYP powder for injection Australia - English - Department of Health (Therapeutic Goods Administration)

technescan pyp powder for injection

landauer radiopharmaceuticals pty ltd - sodium pyrophosphate, quantity: 11.9 mg - injection, powder for - excipient ingredients: stannous chloride dihydrate; water for injections - indications as at 1 february 2005: technetium tc 99m pyrophosphate injection is a skeletal imaging agent used to demonstrate areas of altered osteogenesis, and a cardiac imaging agent used as an adjunct in the diagnosis of acute myocardial infarction. as an adjunct in the diagnosis of confirmed myocardial infarction (ecg and serum enzymes positive), the incidence of false negative images has been found to be 6 percent. false negative images can also occur if made too early in the evolutionary phase of the infarct or too late in the resolution phase. in a limited study involving 22 patients in whom the ecg was positive and serum enzymes questionable or negative, but in whom the final diagnosis of acute myocardial infarction was made, the incidence of false negative images was 23 percent. the incidence of false positive images has been found to be 7 to 9 percent. false positive images have been reported following coronary by-pass graft surgery, in unstable angina pectoris, in old myocardial infarcts, and in car

TechneScan PYP - Kit for radiopharmaceutical preparation  20mg Malta - English - Medicines Authority

technescan pyp - kit for radiopharmaceutical preparation 20mg

curium netherlands b.v westerduinweg 3, 1755 le petten, netherlands - sodium pyrophosphate, decahydrate - kit for radiopharmaceutical preparation - sodium pyrophosphate decahydrate 20 mg - diagnostic radiopharmaceuticals

TECHNESCAN HDP- technetium tc 99m oxidronate injection, powder, lyophilized, for solution United States - English - NLM (National Library of Medicine)

technescan hdp- technetium tc 99m oxidronate injection, powder, lyophilized, for solution

curium us llc - oxidronate disodium (unii: h852yk87wp) (oxidronic acid - unii:71mr4v32ti) - oxidronate disodium 3.15 mg - technescan hdp tc 99m is a diagnostic skeletal imaging agent used to demonstrate areas of altered osteogenesis in adult and pediatric patients. none known. all procedures should be conducted using waterproof gloves. use shielded syringe during transport and administration of tc 99m solutions. - remove plastic disc from technescan hdp vial and cleanse top by swabbing with alcohol. note: if dose is for a single adult patient or for a pediatric patient, see unit dose preparation method below. - place vial in lead vial shield. add 3 to 6 ml of sodium pertechnetate tc 99m solution and secure with a fitted lead cover. in choosing the amount of tc 99m radioactivity to be used, the number of doses desired, the activity of each dose [recommended adult dose is 555 mbq (15 mci) with a range of 370 to 740 mbq (10 to 20 mci)] and radioactive decay must be taken into account. the recommended maximum amount of tc 99m radioactivity to be added to the vial is 11.1 gigabecquerels (300 mci). note: the contents of the vial are