NU-CIPROFLOXACIN TABLETS Canada - English - Health Canada

nu-ciprofloxacin tablets

nu-pharm inc - ciprofloxacin - tablet - 100mg - ciprofloxacin 100mg - quinolones

NU-CIPROFLOXACIN TABLETS Canada - English - Health Canada

nu-ciprofloxacin tablets

nu-pharm inc - ciprofloxacin - tablet - 250mg - ciprofloxacin 250mg - quinolones

NU-CIPROFLOXACIN TABLETS Canada - English - Health Canada

nu-ciprofloxacin tablets

nu-pharm inc - ciprofloxacin - tablet - 500mg - ciprofloxacin 500mg - quinolones

NU-CIPROFLOXACIN TABLETS Canada - English - Health Canada

nu-ciprofloxacin tablets

nu-pharm inc - ciprofloxacin - tablet - 750mg - ciprofloxacin 750mg - quinolones

Quadra Assura CD3367-40QC - Defibrillator, implantable, automatic Australia - English - Department of Health (Therapeutic Goods Administration)

quadra assura cd3367-40qc - defibrillator, implantable, automatic

abbott medical australia pty ltd - 35852 - defibrillator, implantable, automatic - the quadra assura cd3367-40qc is a cardiac resynchronisation therapy device with rf telemetry and it monitors and regulates the patient?s heart rate by providing ventricular tachyarrhythmia therapy and quadripolar pacing with single site pacing. it features a df4 device header and parylene coating. the quadra assura cd3367-40qc is intended to provide ventricular antitachycardia pacing and ventricular defibrillation for automated treatment of life-threatening ventricular arrhythmias. cardiac resynchronization therapy devices (crt-ds) are also intended to resynchronize the right and left ventricles in patients with congestive heart failure. also at/af detection algorithm is indicated for detecting atrial tachyarrhythmias which have been found to be associated with an increased risk of stroke in elderly, hypertensive, pacemaker patients without prior history of af. this device is mr conditional.

Unify Assura CD3361-40 - Defibrillator, implantable, automatic Australia - English - Department of Health (Therapeutic Goods Administration)

unify assura cd3361-40 - defibrillator, implantable, automatic

abbott medical australia pty ltd - 35852 - defibrillator, implantable, automatic - the unify assura cd3361-40 is a cardiac resynchronisation therapy device with rf telemetry and it monitors and regulates the patient?s heart rate by providing ventricular tachyarrhythmia therapy and single site pacing. it features an is-1/df-1 device header. the unify assura cd3361-40 is intended to provide ventricular antitachycardia pacing and ventricular defibrillation for automated treatment of life-threatening ventricular arrhythmias. cardiac resynchronization therapy devices (crt-ds) are also intended to resynchronize the right and left ventricles in patients with congestive heart failure. also at/af detection algorithm is indicated for detecting atrial tachyarrhythmias which have been found to be associated with an increased risk of stroke in elderly, hypertensive, pacemaker patients without prior history of af.

Unify Assura CD3361-40C - Defibrillator, implantable, automatic Australia - English - Department of Health (Therapeutic Goods Administration)

unify assura cd3361-40c - defibrillator, implantable, automatic

abbott medical australia pty ltd - 35852 - defibrillator, implantable, automatic - the unify assura cd3361-40c is a cardiac resynchronisation therapy device with rf telemetry and it monitors and regulates the patient?s heart rate by providing ventricular tachyarrhythmia therapy and single site pacing. it features an is-1/df-1 device header and parylene coating. the unify assura cd3361-40c is intended to provide ventricular antitachycardia pacing and ventricular defibrillation for automated treatment of life-threatening ventricular arrhythmias. cardiac resynchronization therapy devices (crt-ds) are also intended to resynchronize the right and left ventricles in patients with congestive heart failure. also at/af detection algorithm is indicated for detecting atrial tachyarrhythmias which have been found to be associated with an increased risk of stroke in elderly, hypertensive, pacemaker patients without prior history of af.

Unify Assura CD3361-40Q - Defibrillator, implantable, automatic Australia - English - Department of Health (Therapeutic Goods Administration)

unify assura cd3361-40q - defibrillator, implantable, automatic

abbott medical australia pty ltd - 35852 - defibrillator, implantable, automatic - unify assura cd3361-40q is a cardiac resynchronisation therapy device with rf telemetry and it monitors and regulates the patient?s heart rate by providing ventricular tachyarrhythmia therapy and single site pacing. it features a df4 device header. the unify assura cd3361-40q is intended to provide ventricular antitachycardia pacing and ventricular defibrillation for automated treatment of life-threatening ventricular arrhythmias. cardiac resynchronization therapy devices (crt-ds) are also intended to resynchronize the right and left ventricles in patients with congestive heart failure. also at/af detection algorithm is indicated for detecting atrial tachyarrhythmias which have been found to be associated with an increased risk of stroke in elderly, hypertensive, pacemaker patients without prior history of af.