Surgical procedure kit, ophthalmic, non-medicated, single-use Australia - English - Department of Health (Therapeutic Goods Administration)

surgical procedure kit, ophthalmic, non-medicated, single-use

alcon laboratories australia pty ltd - 45150 - surgical procedure kit, ophthalmic, non-medicated, single-use - a collection of various ophthalmic surgical instruments and the necessary accessories to perform an ophthalmic surgical procedure.

Surgical procedure kit, ophthalmic, non-medicated, single-use Australia - English - Department of Health (Therapeutic Goods Administration)

surgical procedure kit, ophthalmic, non-medicated, single-use

alcon laboratories australia pty ltd - 45150 - surgical procedure kit, ophthalmic, non-medicated, single-use - ophthalmic surgical pack that contains devices to perform an ophthalmic surgical procedure.

BSS PLUS- balanced salt solution enriched with bicarbonate, dextrose, and glutathione kit United States - English - NLM (National Library of Medicine)

bss plus- balanced salt solution enriched with bicarbonate, dextrose, and glutathione kit

alcon laboratories, inc. - sodium chloride (unii: 451w47iq8x) (sodium cation - unii:lyr4m0nh37), potassium chloride (unii: 660yq98i10) (potassium cation - unii:295o53k152), sodium phosphate, dibasic, unspecified form (unii: gr686lba74) (sodium cation - unii:lyr4m0nh37), sodium bicarbonate (unii: 8mdf5v39qo) (sodium cation - unii:lyr4m0nh37) - sodium chloride 7.44 mg in 1 ml - indications and usage:  bss plus is indicated for use as an intraocular irrigating solution during intraocular surgical procedures involving perfusion of the eye. contraindications:  there are no specific contraindications to the use of bss plus; however, contraindications for the surgical procedure during which bss plus is to be used should be strictly adhered to. geriatric use:  no overall differences in safety or effectiveness have been observed between elderly and younger patients. reconstitution instructions directions: use aseptic technique - remove the blue flip-off seal from the bss plus® part i (480 ml) bottle. remove the blue flip-off seal from the bss plus part ii (20 ml) vial. prepare the stoppers on both parts by using sterile alcohol wipes. - peel open a bss plus vacuum transfer device package (supplied) and remove the sterile transfer spike. note: this device is vented permitting air to enter vial during solution transfer, thereby preventing the creation of a vacuum inside the vial. an air-inlet filter is provided to protect the system. do not remove the air-inlet filter. - remove protector from the white plastic piercing pin. - firmly grasp device from behind the flange and insert the white plastic piercing pin into the upright rubber stopper of the bss plus part ii (20 ml) vial. - remove guard from filter needle. firmly grasp vial in the palm of one hand and with thumb and index finger, hold plastic flange against top of vial. - invert vial and immediately insert filter needle into the outer target of the rubber stopper of the bss plus part i (480 ml) bottle. (see illustration.) - fluid will automatically transfer from the vial into the large vacuum bottle unless filter becomes occluded or loss of vacuum occurs. note: an excess amount of bss plus part ii is provided in each vial. a non-transferred solution residual of approximately 0.3 ml can be expected to remain in the vial. - immediately remove needle from the bss plus part i container and discard it after solution transfer has been completed. - place a sterile safety cap over the rubber stopper of part i if the solution is not going to be used immediately. mix the solution gently until uniform. peel off the right-hand side of part i bottle label (fully reconstituted bss plus solution). record the patient’s name and the date and time of reconstitution. bss plus solution is now ready for use. caution: reconstituted bss plus solution must be used within six hours of mixing. discard any solution which has aged beyond that time. never use the same bottle of bss plus solution on more than one patient. alternative transfer method if preferred, the contents of the bss plus part ii component may be aspirated with an 18-gauge cannula attached to a 20 ml syringe and then transferred into the part i bottle. alcon distributed by: alcon laboratories, inc. fort worth, texas 76134 usa revised: april 2023

Surgical procedure kit, ophthalmic, non-medicated, single-use Australia - English - Department of Health (Therapeutic Goods Administration)

surgical procedure kit, ophthalmic, non-medicated, single-use

alcon laboratories australia pty ltd - 45150 - surgical procedure kit, ophthalmic, non-medicated, single-use - ophthalmic surgical pack that contains devices to perform an ophthalmic surgical procedure.

Open-surgery electrosurgical forceps, reusable Australia - English - Department of Health (Therapeutic Goods Administration)

open-surgery electrosurgical forceps, reusable

alcon laboratories australia pty ltd - 47848 - open-surgery electrosurgical forceps, reusable - a reusable electrosurgical device used with compatible alcon surgical systems.

Alcon 3000LE™ Ophthalmic YAG Laser Singapore - English - HSA (Health Sciences Authority)

alcon 3000le™ ophthalmic yag laser

alcon pte ltd - ophthalmology - alcon 3000le ophthalmic yag laser is a surgical laser instrument designed for performing posterior capsulotomies, posterior membranectomies, irridotomies, or other procedures that seek to rupture a structure within the eye.

Drape, surgical, general-purpose, single use Australia - English - Department of Health (Therapeutic Goods Administration)

drape, surgical, general-purpose, single use

alcon laboratories australia pty ltd - 35531 - drape, surgical, general-purpose, single use - surgical drapes used during ophthalmic surgery to cover either the patient or items in the operating theatre.

Alcon 56° Soft Tip Needle Single use Singapore - English - HSA (Health Sciences Authority)

alcon 56° soft tip needle single use

alcon pte ltd - ophthalmology - manual ophthalmic surgical instruments used by surgeons to remove fluids in the posterior chamber during ophthalmic surgical procedures. they consist of a blunt stainless steel hypodermic tubing cannula with a silastic tubing affixed at the distal end, attached to a luer taper plastic hub at the proximal end, which may be attached to devices having a 6% male (luer) taper conical fitting. they are transient, single use devices, which are packaged in a tyvek and petg sterile barrier blister package and terminally sterilized.

Alcon Constellation Vision System Singapore - English - HSA (Health Sciences Authority)

alcon constellation vision system

alcon pte ltd - ophthalmology - a multifunctional surgical instrument for use in anterior and posterior segment ophthalmic surgeries. the product’s capabilities include driving a variety of handpieces that provide the ability to cut vitreous and tissues, emulsify the lens, illuminate the posterior segment of the eye, and apply diathermy to stop bleeding. vacuum is used to remove ocular matter from the eye and is provided by connecting tubing from the handpiece to a port on the fluidics cassette. irrigation/infusion capability is provided to replace fluid in the eye, and enters the eye directly through either an infusion cannula or a handpiece. an optional, fully integrated laser delivers a visible 532 nm green treatment beam designed for ophthalmic use.

Alcon ORA SYSTEM with VerifEye Lynk Technology Singapore - English - HSA (Health Sciences Authority)

alcon ora system with verifeye lynk technology

alcon pte ltd - ophthalmology - the alcon ora system with verifeye lynk is intended for use in the measurement and analysis of the refractive power of the eye (i.e., sphere, cylinder, and axis measurements).