neodisher IP Spray

United Kingdom - English - DrWeigert

Buy It Now

Available from:
Dr. Weigert
Authorization number:
PN4304

Documents in other languages

Patient Information leaflet Patient Information leaflet - Spanish

22-09-2017

Summary of Product characteristics Summary of Product characteristics - Spanish

22-09-2017

Patient Information leaflet Patient Information leaflet - German

22-09-2017

Patient Information leaflet Patient Information leaflet - French

22-09-2017

Patient Information leaflet Patient Information leaflet - Italian

08-09-2017

Summary of Product characteristics Summary of Product characteristics - Hungarian

22-09-2017

Patient Information leaflet Patient Information leaflet - Dutch

22-09-2017

Patient Information leaflet Patient Information leaflet - Polish

22-09-2017

Read the complete document

Date revised: 10.04.2017

Print date: 28.06.17

3 / GB- 800830-008-03

Version: 3 / GB

Replaces Version: 2 /

Safety data sheet in accordance with regulation (EC) No

1907/2006

neodisher IP Spray

Page 1(9)

SECTION 1: Identification of the substance/mixture and of the company/undertaking

1.1. Product identifier

neodisher IP Spray

1.2. Relevant identified uses of the substance or mixture and uses advised against

Use of the substance/preparation

Metal surface treatment products, including galvanic and electroplating products

1.3. Details of the supplier of the safety data sheet

Address:

Chemische Fabrik Dr. Weigert GmbH & Co. KG

Mühlenhagen 85

D-20539 Hamburg

Telephone no.

+49 40 789 60 0

Fax no.

+49 40 789 60 120

www.drweigert.com

E-mail address of person responsible for this SDS:

sida@drweigert.de

1.4. Emergency telephone number

GBK/ Infotrac: (USA domestic) 1 800 535 5053 or international +1 352 323 3500

SECTION 2: Hazards identification

2.1. Classification of the substance or mixture

Classification (Regulation (EC) No. 1272/2008)

Classification (Regulation (EC) No. 1272/2008)

Aerosol 1

H222

STOT SE 3

H336

Aquatic Chronic 2

H411

2.2. Label elements

Labelling according to regulation (EC) No 1272/2008

Hazard pictograms

Signal word

Danger

Hazard statements

H222

Extremely flammable aerosol.

H229

Pressurised container: May burst if heated.

H336

May cause drowsiness or dizziness.

H411

Toxic to aquatic life with long lasting effects.

Precautionary statements

P210

Keep away from heat, hot surfaces, sparks, open flames and other ignition

Date revised: 10.04.2017

Print date: 28.06.17

3 / GB- 800830-008-03

Version: 3 / GB

Replaces Version: 2 /

Safety data sheet in accordance with regulation (EC) No

1907/2006

neodisher IP Spray

Page 2(9)

sources. No smoking.

P211

Do not spray on an open flame or other ignition source.

P251

Do not pierce or burn, even after use.

P261

Avoid breathing dust/fume/gas/mist/vapours/spray.

P273

Avoid release to the environment.

P410+P412

Protect from sunlight. Do not expose to temperatures exceeding 50 °C/122°F.

Dispose only when container is empty and closed. For disposal of product

residues, refer to Safety Data Sheet.

Hazardous component(s) to be indicated on label (Regulation (EC) No. 1272/2008)

contains

aliphatic hydrocarbons, C5-C6

2.3. Other hazards

No special hazards have to be mentioned.

SECTION 3: Composition/information on ingredients

3.2. Mixtures

Hazardous ingredients

fatty alcohols, ethoxylated

CAS No.

68920-66-1

EINECS no.

500-236-9

Concentration

>=

<

Classification (Regulation (EC) No. 1272/2008)

Skin Irrit. 2

H315

Aquatic Acute 1

H400

Aquatic Chronic 3

H412

aliphatic hydrocarbons, C5-C6

EINECS no.

931-254-9

Registration no.

01-2119484651-34

Concentration

>=

<

Classification (Regulation (EC) No. 1272/2008)

Flam. Liq. 2

H225

Skin Irrit. 2

H315

STOT SE 3

H336

Asp. Tox. 1

H304

Aquatic Chronic 2

H411

Propane

CAS No.

74-98-6

EINECS no.

200-827-9

Concentration

<

Classification (Regulation (EC) No. 1272/2008)

Flam. Gas 1

H220

Press. Gas

Butane

CAS No.

106-97-8

EINECS no.

203-448-7

Concentration

<

Classification (Regulation (EC) No. 1272/2008)

Flam. Gas 1

H220

Press. Gas

Date revised: 10.04.2017

Print date: 28.06.17

3 / GB- 800830-008-03

Version: 3 / GB

Replaces Version: 2 /

Safety data sheet in accordance with regulation (EC) No

1907/2006

neodisher IP Spray

Page 3(9)

SECTION 4: First aid measures

4.1. Description of first aid measures

General information

Remove contaminated clothing immediately and dispose of safely. In case of persistent symptoms

consult doctor.

After inhalation

Ensure supply of fresh air.

After skin contact

No special measures required.

After eye contact

Separate eyelids, wash the eyes thoroughly with water (15 min.). Seek medical advice immediately.

After ingestion

No special measures required.

4.2. Most important symptoms and effects, both acute and delayed

Until now no symptoms known so far.

4.3. Indication of any immediate medical attention and special treatment needed

Hints for the physician / hazards

In the case of swallowing with subsequent vomiting, aspiration of the lungs can occur which can lead to

chemical pneumonia or asphyxiation.

SECTION 5: Firefighting measures

5.1. Extinguishing media

Suitable extinguishing media

Dry powder, Water spray jet, Foam

Non suitable extinguishing media

Compatible with all usual extinguishing media.

5.2. Special hazards arising from the substance or mixture

In case of combustion evolution of dangerous gases possible. If a fire breaks out nearby, pressure build-

up and danger of bursting are possible.

5.3. Advice for firefighters

Special protective equipment for fire-fighting

Do not inhale explosion and/or combustion gases. In case of combustion use a suitable breathing

apparatus. Wear full protective suit.

SECTION 6: Accidental release measures

6.1. Personal precautions, protective equipment and emergency procedures

Keep away sources of ignition. Ensure adequate ventilation. Use personal protective clothing.

6.2. Environmental precautions

Do not allow to enter drains or waterways. Do not discharge into the subsoil/soil.

6.3. Methods and material for containment and cleaning up

Pick up rest with suitable absorbent materials. Dispose of as prescribed.

6.4. Reference to other sections

Refer to protective measures listed in Sections 7 and 8.

Date revised: 10.04.2017

Print date: 28.06.17

3 / GB- 800830-008-03

Version: 3 / GB

Replaces Version: 2 /

Safety data sheet in accordance with regulation (EC) No

1907/2006

neodisher IP Spray

Page 4(9)

SECTION 7: Handling and storage

7.1. Precautions for safe handling

Advice on safe handling

Provide good ventilation of working area (local exhaust ventilation if necessary). Avoid impact, friction

and electro-static loading; risk of ignition!. Provide good room ventilation even at ground level (vapours

are heavier than air).

Advice on protection against fire and explosion

Keep away from sources of heat and ignition. No smoking. Take precautionary measures against static

discharge.

7.2. Conditions for safe storage, including any incompatibilities

Recommended storage temperature

Value

>

<

Requirements for storage rooms and vessels

No special measures required.

Storage class according to TRGS 510

Storage class according to

TRGS 510

Aerosol dispensers

Further information on storage conditions

Keep container tightly closed. Keep container in a well-ventilated place. Keep in a cool place

7.3. Specific end use(s)

no data

SECTION 8: Exposure controls/personal protection

8.1. Control parameters

Exposure limit values

Pentane

List

EH40

Type

Value

1800

mg/m³

ppm(V)

Status: 2011

Butane

List

EH40

Type

Value

1450

mg/m³

ppm(V)

Short term exposure limit

1810

mg/m³

ppm(V)

Status: 2011; Remarks: carc if more than 0,1% buta-1,3-diene

Other information

There are not known any further control parameters.

8.2. Exposure controls

General protective and hygiene measures

Do not smoke during work time. Do not inhale gases/vapours/aerosols. Do not eat or drink during work

time. Storage of foodstuffs in work rooms is forbidden. Take off immediately all contaminated clothing.

Wash hands before breaks and after work.

Respiratory protection

If workplace limits are exceeded, a respiratory protection approved for this particular job must be worn.

Short term: filter apparatus, filter AX

Date revised: 10.04.2017

Print date: 28.06.17

3 / GB- 800830-008-03

Version: 3 / GB

Replaces Version: 2 /

Safety data sheet in accordance with regulation (EC) No

1907/2006

neodisher IP Spray

Page 5(9)

Hand protection

Not necessary.

Eye protection

Safety glasses with side protection shield (EN 166)

Body protection

Clothing as usual in the chemical industry.

SECTION 9: Physical and chemical properties

9.1. Information on basic physical and chemical properties

Form

Aerosol

Colour

colourless

Odour

characteristic

Odour threshold

Remarks

not determined

pH value

Remarks

Not applicable

Melting point

Remarks

not determined

Freezing point

Remarks

not determined

Initial boiling point and boiling range

Remarks

not determined

Flash point

Remarks

Not applicable

Evaporation rate (ether = 1) :

Remarks

not determined

Flammability (solid, gas)

evaluation

not determined

Upper/lower flammability or explosive limits

Remarks

not determined

Vapour pressure

Remarks

not determined

Vapour density

Remarks

not determined

Density

Value

0,86

g/cm³

Temperature

Solubility in water

Remarks

slightly soluble

Solubility(ies)

Remarks

not determined

Partition coefficient: n-octanol/water

Remarks

not determined

Ignition temperature

Remarks

not determined

Date revised: 10.04.2017

Print date: 28.06.17

3 / GB- 800830-008-03

Version: 3 / GB

Replaces Version: 2 /

Safety data sheet in accordance with regulation (EC) No

1907/2006

neodisher IP Spray

Page 6(9)

Decomposition temperature

Remarks

not determined

Viscosity

Remarks

not determined

Explosive properties

evaluation

not determined

Oxidising properties

evaluation

None known

9.2. Other information

Other information

None known

SECTION 10: Stability and reactivity

10.1. Reactivity

No hazardous reactions when stored and handled according to prescribed instructions.

10.2. Chemical stability

No hazardous reactions known.

10.3. Possibility of hazardous reactions

No hazardous reactions known.

10.4. Conditions to avoid

Protect from heat and direct sunlight. Evolution of flammable mixtures possible in air when heated above

flash point and/or during spraying or misting.

Decomposition temperature

Remarks

not determined

10.5. Incompatible materials

Oxidising agents

10.6. Hazardous decomposition products

No hazardous decomposition products known.

SECTION 11: Toxicological information

11.1. Information on toxicological effects

Acute oral toxicity

Species

LD50

>

2000

mg/kg

Method

calculated value (Regulation (EC) No. 1272/2008)

Acute dermal toxicity

Remarks

Based on available data, the classification criteria are not met.

Acute inhalational toxicity

Remarks

Based on available data, the classification criteria are not met.

Skin corrosion/irritation

evaluation

slightly irritant

Serious eye damage/irritation

Remarks

Based on available data, the classification criteria are not met.

Sensitization

Date revised: 10.04.2017

Print date: 28.06.17

3 / GB- 800830-008-03

Version: 3 / GB

Replaces Version: 2 /

Safety data sheet in accordance with regulation (EC) No

1907/2006

neodisher IP Spray

Page 7(9)

Remarks

Based on available data, the classification criteria are not met.

Subacute, subchronic, chronic toxicity

Remarks

Based on available data, the classification criteria are not met.

Mutagenicity

Remarks

Based on available data, the classification criteria are not met.

Reproductive toxicity

Remarks

Based on available data, the classification criteria are not met.

Carcinogenicity

Remarks

Based on available data, the classification criteria are not met.

Specific Target Organ Toxicity (STOT)

evaluation

May cause drowsiness or dizziness.

Aspiration hazard

No special hazards have to be mentioned.

Other information

There is no data available on the product apart from the information given in this subsection.

SECTION 12: Ecological information

12.1. Toxicity

General information

not determined

Fish toxicity (Components)

fatty alcohols, ethoxylated

Species

zebra fish (Brachydanio rerio)

LC50

mg/l

Duration of exposure

Method

OECD 203

aliphatic hydrocarbons, C5-C6

Species

Fathead minnow (Pimephales promelas)

LC50

mg/l

Duration of exposure

Bacteria toxicity (Components)

fatty alcohols, ethoxylated

Species

activated sludge

EC50

>

1000

mg/l

Method

OECD 209

12.2. Persistence and degradability

General information

not determined

12.3. Bioaccumulative potential

General information

not determined

Partition coefficient: n-octanol/water

Remarks

not determined

12.4. Mobility in soil

General information

Date revised: 10.04.2017

Print date: 28.06.17

3 / GB- 800830-008-03

Version: 3 / GB

Replaces Version: 2 /

Safety data sheet in accordance with regulation (EC) No

1907/2006

neodisher IP Spray

Page 8(9)

not determined

12.5. Results of PBT and vPvB assessment

General information

not determined

Evaluation of persistance and bioaccumulation potential

The product contains no PBT or vPvB substances.

12.6. Other adverse effects

General information

not determined

General information / ecology

The surfactant(s) contained in this preparation complies(comply) with the biodegradability criteria as laid

down in Regulation (EC) No.648/2004 on detergents. Do not discharge product unmonitored into the

environment.

SECTION 13: Disposal considerations

13.1. Waste treatment methods

Disposal recommendations for the product

Allocation of a waste code number, according to the European Waste Catalogue (EWC), should be

carried out in agreement with the regional waste disposal company.

Disposal recommendations for packaging

Packaging that cannot be cleaned should be disposed off in agreement with the regional waste disposal

company.

SECTION 14: Transport information

Land transport ADR/RID

Marine transport

IMDG/GGVSee

Air transport ICAO/IATA

14.1. UN number

1950

1950

1950

14.2. UN proper shipping name

AEROSOLS, flammable

AEROSOLS, flammable

AEROSOLS, flammable

14.3. Transport hazard

class(es)

Label

Limited Quantity

Transport category

14.5. Environmental hazards

Tunnel restriction code

SECTION 15: Regulatory information

15.1. Safety, health and environmental regulations/legislation specific for the substance

Date revised: 10.04.2017

Print date: 28.06.17

3 / GB- 800830-008-03

Version: 3 / GB

Replaces Version: 2 /

Safety data sheet in accordance with regulation (EC) No

1907/2006

neodisher IP Spray

Page 9(9)

or mixture

Major-accident categories acc. 96/82/EC

Category

Extremely flammable

10.000

50.000

Water Hazard Class (Germany)

Water Hazard Class

(Germany)

WGK 1

Remarks

Classification according to Annex 4 VwVwS

VOC

VOC (EU)

Other information

The product does not contain substances of very high concern (SVHC).

15.2. Chemical safety assessment

For this preparation a chemical safety assessment has not been carried out.

SECTION 16: Other information

Hazard statements listed in Chapter 3

H220

Extremely flammable gas.

H225

Highly flammable liquid and vapour.

H304

May be fatal if swallowed and enters airways.

H315

Causes skin irritation.

H336

May cause drowsiness or dizziness.

H400

Very toxic to aquatic life.

H411

Toxic to aquatic life with long lasting effects.

H412

Harmful to aquatic life with long lasting effects.

CLP categories listed in Chapter 3

Aquatic Acute 1

Hazardous to the aquatic environment, acute, Category 1

Aquatic Chronic 2

Hazardous to the aquatic environment, chronic, Category 2

Aquatic Chronic 3

Hazardous to the aquatic environment, chronic, Category 3

Asp. Tox. 1

Aspiration hazard, Category 1

Flam. Gas 1

Flammable gas, Category 1

Flam. Liq. 2

Flammable liquid, Category 2

Press. Gas

Gases under pressure

Skin Irrit. 2

Skin irritation, Category 2

STOT SE 3

Specific target organ toxicity - single exposure, Category 3

Supplemental information

Relevant changes compared with the previous version of the safety data sheet are marked with: ***

This information is based on our present state of knowledge. However, it should not constitute a

guarantee for any specific product properties and shall not establish a legally valid relationship.

Read the complete document

neodisher

IP Spray

Lubricant spray for surgical instruments

Chemische Fabrik Dr. Weigert GmbH & Co. KG

Telefon: (040) 789 60 - 0

E-Mail: info @drweigert.de

Mühlenhagen 85, D – 20539 Hamburg

Telefax: (040) 789 60 - 120

Internet: www. drweigert.de

Die Angaben dieses Merkblattes beruhen auf unseren derzeitigen Kenntnissen und Erfahrungen. Sie befreien den

Verwender nicht von eigenen Prüfungen und Versuchen. Eine rechtlich verbindliche Zusicherung bestimmter

Eigenschaften kann hieraus nicht abgeleitet werden.

With the above information, which is appropriate to our current knowledge we describe

our product regarding possible safety necessities, but we do not involve any quality description

or promise certain properties.

Main fields of application:

Manual lubrication of surgical instruments, especially for hinged instruments.

Characteristics:

neodisher IP Spray is based on highly purified white oil (mineral oil/paraffinum

liquidum of food and pharmaceutical grade) and is used for the direct lubrication of

surgical instruments after automated cleaning if the lubrication in a washer

disinfector is inadequate or if there is no dosing of neodisher IP Konz in the washer

disinfector.

neodisher IP Spray

does not lead to encrustations

does not influence a following steam- or hot air sterilization

is toxicologically harmless

Application and dosage:

Spray neodisher IP Spray directly onto the instruments, especially on the joints. Hold

the spray can as vertically as possible. For the spraying of sieves please use the spray

can with a shortened spraying tube. For this the tube should be removed from the

attachment and cut with a pair of scissors to the required length. Then put the

spraying tube with the shortened side into the spraying attachment to achieve an

optimum spraying result.

Reprocessing should comply with all ordinances pursuant to the Medical Device

Directive and should be performed with appropriate validated processes.

Please observe the instrument manufacturer´s recommendations for use according to

the requirements of DIN EN ISO 17664.

For professional use only.

Toxicology:

If applied as instructed the product is toxicologically safe (assessment in accordance

to EN ISO 10993-1). A summary of the toxicological profile is available on request.

Ingredients:

Pparaffinum liquidum of food and pharmaceutical grade, non-ionic surfactants,

propellant gas propane/butane

CE-marks:

neodisher IP Spray conforms to the European directive 93/42/EEC, Annex I,

concerning medical devices.

Storage information:

Always store at a temperature between 5 and 30 °C.

Usable for 4 years when stored as recommended.

For expiry date refer to the stamp mark on the can.

Hazard warnings

and safety advice:

For further safety information see EC-Material Safety Data Sheet. These are

available e.g. at www.drweigert.de under the category “Service”.

Dispose only when container is empty and closed. For disposal of product residues, refer

to Material Safety Data Sheet.

Container under pressure. Protect from sunlight and do not expose to

temperatures exceeding 50 °C. Do not puncture or burn container even after use.

MB 4304 GB/2-6

Revision date 08/2015

Search alerts related to this product

View documents history

Share this information