Tecnis

Main information

  • Trade name:
  • Tecnis Multifocal 1-piece IOL with Tecnis iTec Preloaded Delivery System - Lens, intraocular, posterior chamber
  • Class:
  • Class III
  • Medicine domain:
  • Humans
  • Medicine type:
  • Medical device

Documents

Localization

  • Available in:
  • Tecnis Multifocal 1-piece IOL with Tecnis iTec Preloaded Delivery System - Lens, intraocular, posterior chamber
    Australia
  • Language:
  • English

Other information

Status

  • Source:
  • Dept. of Health,Therapeutic Goods Administration - Australia
  • Authorization number:
  • 220330
  • Last update:
  • 08-10-2017

Public Assessment Report

Public Summary

Summary for ARTG Entry:

220330

AMO Australia Pty Ltd - Tecnis Multifocal 1-piece IOL with Tecnis iTec Preloaded Delivery System - Lens,

intraocular, posterior chamber

ARTG entry for

Medical Device Included Class III

Sponsor

AMO Australia Pty Ltd

Postal Address

Locked Bag 2005,NORTH RYDE BC, NSW, 1670

Australia

ARTG Start Date

20/02/2014

Product category

Medical Device Class III

Status

Active

Approval area

Medical Devices

Conditions

- The inclusion of the kind of device in the ARTG is subject to compliance with all conditions placed or imposed on the ARTG entry. Refer Part 4-5,

Division 2 (Conditions) of the Therapeutic Goods Act 1989 and Part 5, Division 5.2 (Conditions) of the Therapeutic Goods (Medical Devices) Regulations

2002 for relevant information.

- Breaching conditions of the inclusion related to the device of the kind may lead to suspension or cancellation of the ARTG entry; may be a criminal

offence; and civil penalties may apply.

Manufacturers

Name

Address

Abbott Medical Optics Inc

1700 East Saint Andrew Place

Santa Ana, CA, 92705

United States Of America

Products

1. Tecnis Multifocal 1-piece IOL with Tecnis iTec Preloaded Delivery System - Lens, intraocular, posterior

chamber

Product Type

Medical device system

Effective date

20/02/2014

GMDN

35658 Lens, intraocular, posterior chamber

Functional description

The disposable Tecnis iTec Preloaded Delivery System provides both sterile storage of an foldable

multifocal 1pc acrylic lens & a controlled,convenient,touch-free method of folding the IOL prior to delivering

it into the capsular bag of the eye via a minimally invasive insertion tip. The delivery is manually guided by

the surgeon advancing a twist style handpiece. The IOL is intended to be implanted permanently in the

posterior chamber to replace the natural cataractous crystalline lens.

Intended purpose

TECNIS® Multifocal 1-Piece lens is preloaded into the TECNIS iTec Preloaded Delivery System that is

intended to store, fold and assist with insertion of the pre-loaded lens into the capsular bag of the eye.

TECNIS® multifocal foldable acrylic 1-piece intraocular lenses are indicated for primary implantation for

the visual correction of: [1] aphakia in adults in whom a cataractous lens has been removed, and [2]

aphakia following refractive lensectomy in presbyopic adults who may benefit from useful near vision and

reduced spectacle dependence across a range of distances.

Variant information

Diopter +5D to +34.0D in 0.5D increments

Model number (see guidance docs) PMB00

Specific Conditions

No Specific Conditions included on Record

© Commonwealth of Australia.This work is copyright.You are not permitted to re-transmit, distribute or commercialise the material without obtaining prior

written approval from the Commonwealth.Further details can be found at http://www.tga.gov.au/about/website-copyright.htm.

Public Summary