Plasmafit Poly Acetabular Cups - Acetabular shell Australia - English - Department of Health (Therapeutic Goods Administration)

plasmafit poly acetabular cups - acetabular shell

b braun australia pty ltd - 43167 - acetabular shell - the implant has a thin shell without screws holes and has an increased polyethylene wall thickness with a large articulation diameter and is for cementless use. the combination of plasmafit surface with plasmapore leads to a rough implant surface which supports the direct bone apposition on the increased implant surface. the implant is for vitalene polyethylene liners only. the acetabular shell implant is a component of a human hip endoprosthesis which is coupled with a polyethylene liner and is used for acute disorders of the hip that cannot be treated by other therapies ? degenerative osteoarthritis; rheumatic arthritis; fractures of the joint and femoral head necrosis.

Plasmafit Plus Acetabular Cups - Acetabular shell Australia - English - Department of Health (Therapeutic Goods Administration)

plasmafit plus acetabular cups - acetabular shell

b braun australia pty ltd - 43167 - acetabular shell - the plasmafit plus is a universal cup implant for ceramic and polyethylene cup liners with a screw option. the pressfit locking allows a primary cup stability particularly on the rim of the cup. it has a plasmapore coating which has a rough exterior and supports direct bone apposition on the increased implant surface. the implant is a component of a human hip endoprosthesis to be combined with aesculap hip endoprosthesis components for implantation without bone cement. the implant is intended for use for acute disorders of the hip that cannot be treated by other therapies: - degenerative osteoarthritis - rheumatic arthritis - fractures of the joint - femoral head necrosis

Plasmafit Plus Biolox Delta Ceramic Cup Insert - Ceramic acetabular liner Australia - English - Department of Health (Therapeutic Goods Administration)

plasmafit plus biolox delta ceramic cup insert - ceramic acetabular liner

b braun australia pty ltd - 48055 - ceramic acetabular liner - the plasmafit biolox delta inserts are to be used with plasmafit acetabular cups for total hip arthroplasty. biolox? delta, the latest generation of ceramics in tha, is a high strength aluminium oxide matrix ceramic. finest zio2 particles represent the matrix material. when using ceramic liners the final check for seating is assessed with a fingertip check. after inserting, the liner is fixed using an impactor with a plastic head. the implant is used as a component part of a human hip endoprosthesis to combine with aesculap hip endoprosthesis components for implantation without bone cement. use for acute disorders of the hip that cannot be treated by other therapies: - degenerative osteoarthritis - rheumatic arthritis - fractures of the joint - femoral head necrosis

Plasmafit Dual Mobility Insert - Metallic acetabular liner Australia - English - Department of Health (Therapeutic Goods Administration)

plasmafit dual mobility insert - metallic acetabular liner

b braun australia pty ltd - 48056 - metallic acetabular liner - the plasmafit dual mobility insert is an acetabular component where the outer surface mates with a plasmafit cup and the inner surface is highly polished and serves as the articulation surface for the dual mobility head made of vitelene? (highly cross linked polyethylene with vitamin e). the implant is used ? as a subcomponent of a human hip endoprosthesis: dual mobility insert and dual mobility head ? to combine with aesculap hip endoprosthesis components ? use with aesculap plasmafit? plus cup systems ? the implant components are packed individually; each has a separate article number.

Plasmafit Vitelene PE Cup Insert - Non-constrained polyethylene acetabular liner Australia - English - Department of Health (Therapeutic Goods Administration)

plasmafit vitelene pe cup insert - non-constrained polyethylene acetabular liner

b braun australia pty ltd - 43168 - non-constrained polyethylene acetabular liner - the modular vitelene insert is made of highly cross-linked polyethylene stabilised with vitamin e which provides long term oxidation protection. the inserts are conically clamped in the cup. on the underside of the vitelene there is a prop which is designed to support the inlay lower cup edge when its fully countersunk in the core. the liners with posterior wall (hooded) increase luxation stability. the asymmetrical liners correct the cup position by 10 degrees. the implant is used as a component part of a human hip endoprosthesis to combine with aesculap hip endoprosthesis components for implantation without bone cement. use for acute disorders of the hip that cannot be treated by other therapies: - degenerative osteoarthritis - rheumatic arthritis - fractures of the joint - femoral head necrosis

Plasmafit PE Cup Insert Symmetrical UHMWPE - Non-constrained polyethylene acetabular liner Australia - English - Department of Health (Therapeutic Goods Administration)

plasmafit pe cup insert symmetrical uhmwpe - non-constrained polyethylene acetabular liner

b braun australia pty ltd - 43168 - non-constrained polyethylene acetabular liner - the 32mm symmetrical inserts are made of uhmwpe highly cross-linked polyethylene. the fixation of the liners is realized by a conical locking mechanism. the conical fixation surface area also forms a seal against the migration of polyethylene particles from the articulating joint. in the primary load area the liners have a minimum thickness of 5.5 mm. the fixation has a high stability against tilting and rotation forces in vivo. the implant is used as a component part of a human hip endoprosthesis to combine with aesculap hip endoprosthesis components for implantation without bone cement. use for acute disorders of the hip that cannot be treated by other therapies: - degenerative osteoarthritis - rheumatic arthritis - fractures of the joint - femoral head necrosis